The energy dependence of BaSO4: Eu nanophosphors for thermoluminescence dosimetry of orthovoltage X-rays and low

被引:3
|
作者
Nattudurai, Ravikumar [1 ,4 ]
Arous, Delmon [1 ,2 ]
Edin, Nina F. J. [1 ]
Pandey, Anant [3 ]
Malinen, Eirik [1 ,2 ]
机构
[1] Univ Oslo, Dept Phys, Oslo, Norway
[2] Oslo Univ Hosp, Dept Med Phys, Oslo, Norway
[3] Univ Delhi, Sri Venkateswara Coll, Dept Phys, New Delhi, India
[4] Univ Oslo, Dept Phys, Sect Biophys & Med Phys, Oslo, Norway
关键词
Thermoluminescence; X-rays; Protons; Dosimetry; Energy dependence; TRACK STRUCTURE-THEORY; RADIATION-THERAPY; TL; SPECTRA;
D O I
10.1016/j.radphyschem.2023.110928
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Accurate dosimetry of ionizing radiation requires careful consideration of the absorption properties of the dosimeter material in question. The energy dependence of a dosimeter signifies the variation in dosimeter signal per absorbed dose to water with radiation type and energy. The nanophosphor BaSO4: Eu is a radiosensitive material for thermoluminescence (TL) dosimetry. However, the energy dependence of the material for orthovoltage X-rays and low energy protons has not previously been investigated, which is the purpose of the current work. We irradiated BaSO4 doped with 0.5 mol% of europium with 100, 160 and 225 kV X-rays and 2 and 9 MeV protons. Co-60 gamma-rays were used for reference irradiation. Absolute dose-to-water dosimetry was ensured with an ion chamber. Delivered calibration doses ranged from 0.01 to about 2 Gy. TL output was measured at a heating rate of 5 K/s, where the maximum intensity of the dominant glow peak at about 212 degrees C defined the dosimeter signal. The signal was found to increase linearly with absorbed dose for both radiation types and all energies. The measured energy response, defined as the ratio of the TL calibration slope at a given radiation type and energy to that following Co-60 gamma-irradiation, varied between 47 and 62 for X-rays and between 0.41 and 0.61 for protons. Theoretical modelling of the energy response and proton detector efficiency gave similar trends. The findings show that BaSO4 is an energy-dependent material, especially for X-rays, but may still prove valuable for accurate dose determination if the dosimeter is calibrated in the user beam.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Thermoluminescence of BaSO4:Eu irradiated with 48MeV Li3+ and 150 MeV Ag12+ ions
    Salah, Numan
    Lochab, S. P.
    Kanjilal, D.
    Mehra, Jyoti
    Sahare, P. D.
    Ranjan, Ranju
    Rupasov, A. A.
    Aleynikov, V. E.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2008, 41 (08)
  • [42] ATTENUATION OF LOW-ENERGY X-RAYS IN THE AIR
    DIETZSCH, W
    ISOTOPENPRAXIS, 1987, 23 (12): : 456 - 459
  • [43] ELECTRET DOSIMETER FOR LOW-ENERGY X-RAYS
    RICARD, M
    LISBONA, A
    MORUCCI, JP
    ROULLEAU, J
    NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (01): : 129 - 130
  • [44] Benchmark of PENELOPE for low and medium energy X-rays
    Chica, U.
    Anguiano, M.
    Lallena, A. M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (02): : 51 - 57
  • [45] DETECTION OF LOW-ENERGY COSMIC X-RAYS
    FRANCEY, RJ
    BAIRD, GA
    GREEN, DW
    WILSON, BG
    WOOLLAM, WH
    NUCLEAR INSTRUMENTS & METHODS, 1973, 107 (03): : 589 - 595
  • [47] RESPONSE DEPENDENCE OF FILM BADGES FOR X-RAYS AND GAMMA-RAYS ON X-RAY QUALITY IN THE LOW-ENERGY REGION
    SAKIHARA, K
    MATSUMOTO, T
    NAOI, J
    YAMACHI, I
    KATO, A
    FUKUDA, K
    MATSUMOTO, S
    HEALTH PHYSICS, 1985, 49 (02): : 377 - 377
  • [48] MEASUREMENT OF LOW ENERGY X-RAYS .4. TOTAL ABSORPTION IONIZATION CHAMBER
    GREENING, JR
    RANDLE, KJ
    REDPATH, AT
    PHYSICS IN MEDICINE AND BIOLOGY, 1968, 13 (04): : 635 - &
  • [49] SEMICONDUCTOR DETECTOR PERFORMANCE FOR LOW-ENERGY X-RAYS
    JAKLEVIC, JM
    WALTON, JT
    MCMURRAY, RE
    MADDEN, NW
    GOULDING, FS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3): : 598 - 601
  • [50] THE USE OF SCINTILLATION COUNTERS IN THE MEASUREMENT OF THE ENERGY OF X-RAYS AND LOW ENERGY GAMMA-RAYS
    JOHANSSON, SAE
    ARKIV FOR FYSIK, 1952, 3 (06): : 533 - 545