The energy dependence of BaSO4: Eu nanophosphors for thermoluminescence dosimetry of orthovoltage X-rays and low

被引:3
|
作者
Nattudurai, Ravikumar [1 ,4 ]
Arous, Delmon [1 ,2 ]
Edin, Nina F. J. [1 ]
Pandey, Anant [3 ]
Malinen, Eirik [1 ,2 ]
机构
[1] Univ Oslo, Dept Phys, Oslo, Norway
[2] Oslo Univ Hosp, Dept Med Phys, Oslo, Norway
[3] Univ Delhi, Sri Venkateswara Coll, Dept Phys, New Delhi, India
[4] Univ Oslo, Dept Phys, Sect Biophys & Med Phys, Oslo, Norway
关键词
Thermoluminescence; X-rays; Protons; Dosimetry; Energy dependence; TRACK STRUCTURE-THEORY; RADIATION-THERAPY; TL; SPECTRA;
D O I
10.1016/j.radphyschem.2023.110928
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Accurate dosimetry of ionizing radiation requires careful consideration of the absorption properties of the dosimeter material in question. The energy dependence of a dosimeter signifies the variation in dosimeter signal per absorbed dose to water with radiation type and energy. The nanophosphor BaSO4: Eu is a radiosensitive material for thermoluminescence (TL) dosimetry. However, the energy dependence of the material for orthovoltage X-rays and low energy protons has not previously been investigated, which is the purpose of the current work. We irradiated BaSO4 doped with 0.5 mol% of europium with 100, 160 and 225 kV X-rays and 2 and 9 MeV protons. Co-60 gamma-rays were used for reference irradiation. Absolute dose-to-water dosimetry was ensured with an ion chamber. Delivered calibration doses ranged from 0.01 to about 2 Gy. TL output was measured at a heating rate of 5 K/s, where the maximum intensity of the dominant glow peak at about 212 degrees C defined the dosimeter signal. The signal was found to increase linearly with absorbed dose for both radiation types and all energies. The measured energy response, defined as the ratio of the TL calibration slope at a given radiation type and energy to that following Co-60 gamma-irradiation, varied between 47 and 62 for X-rays and between 0.41 and 0.61 for protons. Theoretical modelling of the energy response and proton detector efficiency gave similar trends. The findings show that BaSO4 is an energy-dependent material, especially for X-rays, but may still prove valuable for accurate dose determination if the dosimeter is calibrated in the user beam.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Evaluation of the shielding effectiveness of a non-toxic, double-layered BaSO4/W composite against diagnostic X-rays
    Nakamura, Kenji
    Kubo, Kazuki
    Hirata, Makoto
    Sakai, Yusuke
    Nakamura, Yasunori
    Kosaka, Hiroyuki
    Monzen, Hajime
    Radiation Physics and Chemistry, 2024, 219
  • [32] Evaluation of the shielding effectiveness of a non-toxic, double-layered BaSO4/W composite against diagnostic X-rays
    Nakamura, Kenji
    Kubo, Kazuki
    Hirata, Makoto
    Sakai, Yusuke
    Nakamura, Yasunori
    Kosaka, Hiroyuki
    Monzen, Hajime
    RADIATION PHYSICS AND CHEMISTRY, 2024, 219
  • [33] GALACTIC-LATITUDE DEPENDENCE OF LOW-ENERGY DIFFUSE X-RAYS
    YENTIS, DJ
    VANDENBO.P
    NOVICK, R
    ASTROPHYSICAL JOURNAL, 1972, 177 (02): : 375 - &
  • [34] LOW-ENERGY DIFFUSE X-RAYS
    BUNNER, AN
    COLEMAN, PL
    KRAUSHAAR, WL
    MCCAMMON, D
    ASTROPHYSICAL JOURNAL, 1971, 167 (01): : L3 - +
  • [35] LOW-ENERGY COSMIC X-RAYS
    SHUKLA, PG
    WILSON, BG
    ASTROPHYSICAL JOURNAL, 1971, 164 (02): : 265 - &
  • [36] EPR DOSIMETRY OF CORTICAL BONE AND TOOTH ENAMEL IRRADIATED WITH X-RAYS AND GAMMA-RAYS - STUDY OF ENERGY-DEPENDENCE
    SCHAUER, DA
    DESROSIERS, MF
    LE, FG
    SELTZER, SM
    LINKS, JM
    RADIATION RESEARCH, 1994, 138 (01) : 1 - 8
  • [37] RESEARCH ON DOSIMETRY STANDARDS FOR HIGH ENERGY X-RAYS AND ELECTRONS.
    Tomimasu, T.
    Noguchi, T.
    Kimura, M.
    Sugiyama, S.
    Mikado, T.
    Yamazaki, T.
    Chiwaki, M.
    Bulletin of the Electrotechnical Laboratory, Tokyo, 1983, 47 (9-10): : 876 - 889
  • [38] Barriers to energy dispersive spectrometry with low energy X-rays
    Rickerby, DG
    MIKROCHIMICA ACTA, 1996, : 493 - 500
  • [39] Thermoluminescence spectra of MgAl2O4 irradiated with X-rays
    Kim, TK
    Choe, HS
    Lee, JI
    Whang, CN
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 1997, 31 (02) : 347 - 351
  • [40] On the production of X-rays by low energy ion beams
    Joy, David C.
    Meyer, Harry M., III
    Bolorizadeh, Mehdi
    Lin, Yinghong
    Newbury, Dale
    SCANNING, 2007, 29 (01) : 1 - 4