In-depth numerical analysis of combustion and NOx emission characteristics in a 125 MWe biomass boiler

被引:13
|
作者
Trinh, Viet Thieu [1 ]
Kim, Seung-Mo [2 ]
Kim, Kang-Min [2 ]
Lee, Byoung-Hwa [2 ]
Jeong, Tae-Yong [2 ]
Son, Ju-Seong [3 ]
Kim, Jong-Man [3 ]
Jeon, Chung-Hwan [1 ,2 ]
机构
[1] Pusan Natl Univ, Sch Mech Engn, 2, Busandaehak ro 63 beon gil, Pusan 46241, South Korea
[2] Pusan Natl Univ, Pusan Clean Energy Res Inst, 2,Busandaehak ro 63 beon gil, Pusan 46241, South Korea
[3] Korea South East Power Co, Yeongdong Eco Power Div, 99 YeomJeon gil, Gangneung si 25620, Gangwon do, South Korea
基金
新加坡国家研究基金会;
关键词
Biomass boiler; NOx emissions; Particle size; Char conversion; Active burner; PULVERIZED-COAL BOILER; TORREFIED BIOMASS; FUEL COMBUSTION; WEIGHTED-SUM; SIMULATION; BEHAVIORS; MODEL; RATIO;
D O I
10.1016/j.fuel.2022.125961
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A 125MWe Yeongdong retrofit boiler burning 100 % biomass was adopted for electricity generation to achieve net zero energy emissions by 2050. However, the high volatile content of biomass affects temperature distri-bution and NOx mechanism compared to coal. Additionally, the wide range of particle size inlet results in large amounts of ash at the hopper and high unburned carbon of bottom ash. Here, an in-depth 3D numerical simu-lation was performed for the combustion and nitrogen oxides (NOx) emission behavior in the biomass boiler. The effect of biomass particle size, active burners on the char conversion at the boiler and bottom outlet, and particle residence time were assessed to determine the particle size range. The simulation results were validated by comparison with the actual data. The volatile burnout rate was significantly higher and faster than that of char burnout, and the burner throat exhibits the highest temperature range (approximately 1800-2100 K). Regarding NOx emission, the rate of thermal NOx was higher than that of total NOx, and the reduction of NOx was also significantly high to contribute the low NOx emission at boiler outlet. In addition, char conversion had signif-icantly depended on the position of the active burner, and particle size below 665 mu m can be entrained upward to the boiler outlet with char conversion over 96.85 % at boiler outlet and 100 % at bottom hopper. Therefore, analysis on each active burner can be used to find optimal standby burner while the particle size analysis sug-gested that percentage of particles larger than 665 mu m should be reduced in the biomass boiler. The high -temperature propensity can aid in understanding the deposition behavior in biomass boilers.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Numerical investigation on the flow, combustion and NOx emission characteristics in a 500 MWe tangentially fired pulverized-coal boiler
    Choi, Choeng Ryul
    Kim, Chang Nyung
    FUEL, 2009, 88 (09) : 1720 - 1731
  • [2] Numerical investigation on the flow, combustion, and NOx emission characteristics in a 660 MWe tangential firing ultra-supercritical boiler
    Sun, Wenjing
    Zhong, Wenqi
    Yu, Aibing
    Liu, Longhai
    Qian, Yujun
    ADVANCES IN MECHANICAL ENGINEERING, 2016, 8 (02) : 1 - 13
  • [3] Combustion and NOx emission characteristics of a retrofitted down-fired 660 MWe utility boiler at different loads
    Li, Zhengqi
    Liu, Guangkui
    Zhu, Qunyi
    Chen, Zhichao
    Ren, Feng
    APPLIED ENERGY, 2011, 88 (07) : 2400 - 2406
  • [4] Numerical optimization of combustion and NOX emission in a retrofitted 600MWe tangentially-fired boiler using lignite
    Bian, Caixia
    Huang, Junlin
    Sun, Rongyue
    APPLIED THERMAL ENGINEERING, 2023, 226
  • [5] Numerical simulation study on combustion characteristics and NOx emission of COREX gas swirl burner and boiler
    Liu, Jingwen
    Zhu, Yifan
    Zhou, Hao
    FUEL, 2023, 352
  • [6] Effect of biomass co-firing position on combustion and NOX emission in a 300-MWe coal-fired tangential boiler
    Tu, Yaojie
    Li, Jianlan
    Chang, Dongfeng
    Hu, Bo
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2022, 17 (01)
  • [7] Influence of the Overfire Air Ratio on the NOx Emission and Combustion Characteristics of a down-Fired 300-MWe Utility Boiler
    Ren, Feng
    Li, Zhengqi
    Chen, Zhichao
    Fan, Subo
    Liu, Guangkui
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (16) : 6510 - 6516
  • [8] Experiment and numerical simulation investigations of the combustion and NOx emissions characteristics of an over-fire air system in a 600 MWe boiler
    Zeng, Lingyan
    Jiang, Zhaohua
    Li, Xiaoguang
    Chen, Zhichao
    Zhang, Jia
    Song, Minghang
    Li, Zhengqi
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2017, 71 (09) : 944 - 961
  • [9] Asymmetric combustion characteristics and NOx emissions of a down-fired 300 MWe utility boiler at different boiler loads
    Kuang, Min
    Li, Zhengqi
    Zhang, Yan
    Chen, Xiachao
    Jia, Jinzhao
    Zhu, Qunyi
    ENERGY, 2012, 37 (01) : 580 - 590
  • [10] NUMERICAL SIMULATION OF NOx EMISSION CHARACTERISTICS DURING COMBUSTION IN 350 MW SUPERCRITICAL COGENERATION TANGENTIALLY BOILER
    Wang, Wei-Shu
    Huang, Zhi-Hao
    Tian, Miao
    Wang, Ji-Hong
    Shangguan, Shan-Shan
    Yao, Ming-Yu
    THERMAL SCIENCE, 2020, 24 (05): : 2717 - 2728