Numerical investigation on the flow, combustion and NOx emission characteristics in a 500 MWe tangentially fired pulverized-coal boiler

被引:178
|
作者
Choi, Choeng Ryul [2 ]
Kim, Chang Nyung [1 ,3 ]
机构
[1] Kyung Hee Univ, Coll Adv Technol, Yongin 446701, Gyeonggi Do, South Korea
[2] Kyung Hee Univ, Coll Adv Technol, Dept Mech Engn, Yongin 446701, Gyeonggi Do, South Korea
[3] Kyung Hee Univ, Ind Liaison Res Inst, Yongin 446701, Gyeonggi Do, South Korea
关键词
Tangentially fired pulverized-coal boiler; Combustion simulation; Nitrogen oxide (NOx) emissions; GAS TEMPERATURE DEVIATION; RADIANT-HEAT TRANSFER; FINITE-VOLUME METHOD; UTILITY FURNACE; NO(X) EMISSION; PREDICTION; FUEL; FLAMES;
D O I
10.1016/j.fuel.2009.04.001
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The characteristics of the flow, combustion, temperature and NOx emissions in a 500 MWe tangentially fired pulverized-coal boiler are numerically studied using comprehensive models, with emphasis on fuel and thermal NOx formations. The comparison between the measured values and predicted results shows good agreement, which implies that the adopted combustion and NOx formation models are suitable for correctly predicting characteristics of the boiler. The relations among the predicted temperature, O-2 and CO2 mass fractions are discussed based on the calculated distributions. The predicted results clearly show that NOx formation within the boiler highly depends on the combustion processes as well as the temperature and species concentrations. The results obtained from this study have shown that overfire air (OFA) operation is an efficient way to reduce the NOx emissions of the pulverized-coal fired boiler. Air staging combustion technology (OFA operation) adopted in this boiler has helped reduce fuel NOx formation as well as thermal NOx formation under the present simulated conditions. The decrease in the formation of fuel NOx is due to the decreased contact of the nitrogen from the fuel with the oxygen within the combustion air, while the decrease in thermal NOx formation is caused by a decrease in temperature. The detailed results presented in this paper may enhance the understanding of complex flow patterns, combustion processes and NOx emissions in tangentially fired pulverized-coal boilers, and may also provide a useful basis for NOx reduction and control. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1720 / 1731
页数:12
相关论文
共 50 条
  • [1] CFD investigation on the flow and combustion in a 300 MWe tangentially fired pulverized-coal furnace
    Khaldi, Nawel
    Chouari, Yoldoss
    Mhiri, Hatem
    Bournot, Philippe
    [J]. HEAT AND MASS TRANSFER, 2016, 52 (09) : 1881 - 1890
  • [2] CFD investigation on the flow and combustion in a 300 MWe tangentially fired pulverized-coal furnace
    Nawel Khaldi
    Yoldoss Chouari
    Hatem Mhiri
    Philippe Bournot
    [J]. Heat and Mass Transfer, 2016, 52 : 1881 - 1890
  • [3] Methane Gas Cofiring Effects on Combustion and NOx Emission in 550 MW Tangentially Fired Pulverized-Coal Boiler
    Kim, Kang-Min
    Kim, Gyu-Bo
    Lee, Byoung-Hwa
    Jeon, Chung-Hwan
    Keum, Joon-Ho
    [J]. ACS OMEGA, 2021, 6 (46): : 31132 - 31146
  • [4] CFD modeling of hydrodynamics, combustion and NOx emission in a tangentially fired pulverized-coal boiler at low load operating conditions
    Chang, Jian
    Wang, Xin
    Zhou, Zhijian
    Chen, Honggang
    Niu, Yuguang
    [J]. ADVANCED POWDER TECHNOLOGY, 2021, 32 (02) : 290 - 303
  • [5] Combustion characteristics of a front-wall-fired pulverized-coal 300 MWe utility boiler
    Costa, M
    Azevedo, JLT
    Carvalho, MG
    [J]. COMBUSTION SCIENCE AND TECHNOLOGY, 1997, 129 (1-6) : 277 - 293
  • [6] Numerical investigation on oxy-combustion characteristics of a 200 MWe tangentially fired boiler
    Guo, Junjun
    Liu, Zhaohui
    Wang, Peng
    Huang, Xiaohong
    Li, Jing
    Xu, Ping
    Zheng, Chuguang
    [J]. FUEL, 2015, 140 : 660 - 668
  • [7] Effects of burner tilt angle on the combustion and NOx emission characteristics of a 700 MWe deep-air-staged tangentially pulverized-coal-fired boiler
    Tan, Peng
    Tian, Dengfeng
    Fang, Qingyan
    Ma, Lun
    Zhang, Cheng
    Chen, Gang
    Zhong, Lijin
    Zhang, Honggang
    [J]. FUEL, 2017, 196 : 314 - 324
  • [8] Computational investigation of hydrodynamics, coal combustion and NOx emissions in a tangentially fired pulverized coal boiler at various loads
    Chang, Jian
    Zhou, Zhijian
    Ma, Xinrui
    Liu, Jinshuo
    [J]. PARTICUOLOGY, 2022, 65 : 105 - 116
  • [9] NUMERICAL STUDY ON THE INFLUENCE OF PLATEN SUPER-HEATER ON COMBUSTION CHARACTERISTICS IN A 600 MW TANGENTIALLY FIRED PULVERIZED-COAL BOILER
    Chen, Kai
    Liu, Xinfei
    Qin, Yao
    [J]. THERMAL SCIENCE, 2021, 25 (02): : 833 - 843
  • [10] Investigation of the flow, combustion, heat-transfer and emissions from a 609 MW utility tangentially fired pulverized-coal boiler
    Yin, C
    Caillat, S
    Harion, JL
    Baudoin, B
    Perez, E
    [J]. FUEL, 2002, 81 (08) : 997 - 1006