Biomechanical Evaluation of TensionLoc Versus the Double Spike Plate for ACL Graft Tibial Fixation

被引:1
|
作者
Jernick, Michael [1 ]
Borden, Peter S. [1 ,2 ]
Seager, Andorra [1 ,2 ]
McGarry, Michelle H. [1 ]
Adamson, Gregory J. [1 ]
Lee, Thay Q. [1 ]
机构
[1] Congress Med Fdn, Orthopaed Biomech Lab, Pasadena, CA USA
[2] Sports & Spine Orthopaed, Torrance, CA USA
关键词
anterior cruciate ligament reconstruction; biomechanical properties; bone-patellar tendon-bone graft; quadriceps graft; TensionLoc; tibial fixation; ANTERIOR CRUCIATE LIGAMENT; QUADRICEPS TENDON AUTOGRAFT; SUSPENSORY FIXATION; PATELLAR TENDON; RECONSTRUCTION; TUNNEL; DEVICE; BUTTON;
D O I
10.1177/23259671231169198
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background:The optimal tibial fixation of anterior cruciate ligament (ACL) reconstruction (ACLR) grafts remains controversial. Purpose/Hypothesis:The purpose of this study was to compare the biomechanical characteristics of the TensionLoc (TL) cortical fixation device with the Double Spike Plate (DSP) fixation device for ACL tibial fixation using both bone-patellar tendon-bone (BTB) and quadriceps grafts. It was hypothesized that there would be no differences in biomechanical characteristics between the fixation devices regardless of graft type. Study Design:Controlled laboratory study. Methods:ACLR was performed on 14 matched-pair cadaveric knee specimens-7 pairs using quadriceps grafts (n = 3 male cadaveric knee specimens; n = 4 female cadaveric knee specimens; age, 51 +/- 8 years) and 7 pairs using BTB grafts (n = 3 male cadaveric knee specimens; n = 4 female cadaveric knee specimens; age, 50 +/- 7 years). One side of each pair was randomized to receive DSP fixation, and the contralateral side received TL fixation. Specimens underwent cyclic ramp loading (10 cycles each at 50-100 N, 50-250 N, and 50-400 N), followed by load-to-failure testing, with the tensile force in line with the tibial tunnel. Results between the 2 fixation types were compared with a paired t test. Results:For the quadriceps graft, there were no significant differences in cyclic loading or load-to-failure characteristics between fixation types (P >= .092 for all parameters). For the BTB graft, TL fixation resulted in higher stiffness than DSP at all cyclic testing cycles except for cycle 1 during 100-N loading and had lower displacement at 250-N loading (3.4 +/- 0.1 vs 5.4 +/- 0.3 mm; P = .045). For load to failure, TL fixation resulted in higher stiffness than DSP fixation (232 +/- 3.1 vs 188.4 +/- 6.4 N/mm; P = .046); however, all other load-to-failure parameters were not statistically different (P >= .135 for all parameters). Conclusion:With the quadriceps tendon graft, there were no significant differences in biomechanical characteristics between TL and DSP ACL tibial fixations; however, with BTB grafts, the TL tibial fixation demonstrated greater biomechanical integrity than the DSP tibial fixation.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Supplementary medial locking plate fixation of Ludloff osteotomy versus sole lag screw fixation: A biomechanical evaluation
    Chatzistergos, Panagiotis E.
    Karaoglanis, George C.
    Kourkoulis, Stavros K.
    Tyllianakis, Minos
    Stamatis, Emmanouil D.
    CLINICAL BIOMECHANICS, 2017, 47 : 66 - 72
  • [32] Biomechanical Evaluation of Tibial Eminence Fractures Using Suture Fixation
    Aoki, Stephen K.
    Curtis, Stuart H.
    ORTHOPEDICS, 2011, 34 (12) : 953 - 953
  • [33] Biomechanical evaluation of different fixation methods for tibial eminence fractures
    Eggers, Anne Kathleen
    Becker, Christoph
    Weimann, Andre
    Herbort, Mirco
    Zantop, Thore
    Raschke, Michael J.
    Petersen, Wolf
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (03): : 404 - 410
  • [34] Biomechanical testing of hamstring graft tibial tunnel fixation with bioabsorbable interference screws
    Caborn, DNM
    Nyland, J
    Selby, J
    Tetik, O
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (09): : 991 - 996
  • [35] Graft failure versus graft fixation in ACL reconstruction: histological and immunohistochemical studies in rabbits
    Hsu, Shan-Ling
    Wang, Ching-Jen
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (09) : 1197 - 1202
  • [36] Tibial Pilon fractures Internal plate fixation versus external wire fixation
    Suthorn Bavonratanavech
    Ian Harris
    Beate P. Hanson
    Mohit Bhandari
    中华创伤骨科杂志, 2005, (07) : 680 - 683
  • [37] Double-Bundle and Double-Tunnel ACL Reconstruction With Looped Proximal Tibial Fixation
    Berumen-Nafarrate, Edmundo
    Leal-Contreras, Carlos
    ORTHOPEDICS, 2011, 34 (06) : 441 - 447
  • [38] Graft failure versus graft fixation in ACL reconstruction: histological and immunohistochemical studies in rabbits
    Shan-Ling Hsu
    Ching-Jen Wang
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 1197 - 1202
  • [39] Significant Loss of ACL Graft Force With Tibial-Sided Soft Tissue Interference Screw Fixation Over 24 Hours: A Biomechanical Study
    Kruppa, Philipp
    Flies, Anne
    Wulsten, Dag
    Collette, Robert
    Duda, Georg N.
    Schaser, Klaus-Dieter
    Becker, Roland
    Kopf, Sebastian
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (05)
  • [40] A Biomechanical Evaluation of Various Double Krackow Suture Techniques for Soft-Tissue Graft Fixation
    Hong, Chih-Kai
    Lin, Cheng-Li
    Kuan, Fa-Chuan
    Wang, Ping-Hui
    Yeh, Ming-Long
    Su, Wei-Ren
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (03): : 663 - 668