Differentiation of Crohn's disease, ulcerative colitis, and intestinal tuberculosis by dual-layer spectral detector CT enterography

被引:1
|
作者
Huang, M. [1 ,2 ]
Tu, L. [3 ]
Li, J. [1 ,2 ]
Yue, X. [1 ,2 ]
Wu, L. [1 ,2 ]
Yang, M. [1 ,2 ]
Chen, Y. [1 ,2 ]
Han, P. [1 ,2 ]
Li, X. [1 ,2 ,5 ]
Zhu, L. [3 ,4 ]
机构
[1] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Radiol, Wuhan, Peoples R China
[2] Hubei Prov Key Lab Mol Imaging, Wuhan, Peoples R China
[3] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Div Gastroenterol, Wuhan, Peoples R China
[4] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Div Gastroenterol, 1277 Jiefang Rd, Wuhan 430022, Hubei Province, Peoples R China
[5] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Radiol, 1277 JieFang Rd, Wuhan 430022, Hubei Province, Peoples R China
关键词
INFLAMMATORY-BOWEL-DISEASE; ENERGY CT; COMPUTED-TOMOGRAPHY; IODINE DENSITY; ACTIVITY INDEX; MANAGEMENT; DIAGNOSIS; CONSENSUS;
D O I
10.1016/j.crad.2023.12.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To investigate the value of radiological features and energy spectrum quantitative parameters in the differential diagnosis of Crohn's disease (CD), ulcerative colitis (UC), and intestinal tuberculosis (ITB) by dual-layer spectral detector computed tomography (CT) enterography (CTE). MATERIALS AND METHODS: Clinical and CTE data were collected from 182 patients with CD, 29 with UC, and 51 with ITB. CT images were obtained at the enteric phases and portal phases. The quantitative energy spectrum parameters were iodine density (ID), normalised ID (NID), virtual non-contrast (VNC) value, and effective atomic number (Z-eff). The area under curve (AUC) of the receiver operating characteristic curve (ROC) was calculated. RESULTS: The vascular comb sign (p=0.0 09) and enlarged lymph nodes (p=0.001) were more common in patients with CD than UC or ITB. In the differentiation of moderate-severe active CD from UC, enteric phase NID (AUC, 0.938; p<0.001) and portal phase Z-eff (AUC, 0.925; p<0.001) had the highest accuracy, which were compared separately. In the differentiation of moderate-severe active CD from ITB, enteric phase NID (AUC, 0.906; p<0.001) and portal phase Z-eff (AUC, 0.947; p<0.001) had the highest accuracy; however, the AUC value was highest when the four parameters are combined (AUC, 0.989; p<0.001; AUC, 0.986; p<0.001; AUC, 0.936; p<0.001; and AUC, 0.986; p<0.001) . CONCLUSION: The present study shows that the combined strategies of four parameters have higher sensitivity and specificity in differentiating CD, UC, and ITB, and may play a key role in guiding treatment. (c) 2023 Published by Elsevier Ltd on behalf of The Royal College of Radiologists.
引用
收藏
页码:e482 / e489
页数:8
相关论文
共 50 条
  • [1] Iodine Imaging at Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Dhanantwari, A.
    Halliburton, S.
    Wen, G.
    Utrup, S.
    Jordan, D.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3657 - 3657
  • [2] Objective Image Characterization of Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Halliburton, S.
    Dhanantwari, A.
    Wen, G.
    Utrup, S.
    Jordan, D.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3836 - 3836
  • [3] Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of keV settings and its added value for Crohn’s disease
    Sang Min Lee
    Se Hyung Kim
    Su Joa Ahn
    Hyo-Jin Kang
    Ji Hee Kang
    Joon Koo Han
    [J]. European Radiology, 2018, 28 : 2525 - 2534
  • [4] Virtual monoenergetic dual-layer, dual-energy CT enterography: optimization of keV settings and its added value for Crohn's disease
    Lee, Sang Min
    Kim, Se Hyung
    Ahn, Su Joa
    Kang, Hyo-Jin
    Kang, Ji Hee
    Han, Joon Koo
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (06) : 2525 - 2534
  • [5] Expression of tight junction proteins in Crohn's disease, ulcerative colitis and intestinal tuberculosis
    Das, P.
    Makharia, G. K.
    Goswami, P.
    Sreenivas, V.
    Ahuja, V.
    Gupta, S. D.
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2010, 25 : A12 - A13
  • [6] Objective image characterization of a spectral CT scanner with dual-layer detector
    Ozguner, Orhan
    Dhanantwari, Amar
    Halliburton, Sandra
    Wen, Gezheng
    Utrup, Steven
    Jordan, David
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02):
  • [7] The Application of Dual-layer Spectral Detector CT in Abdominal Vascular Imaging
    Lai, Lu-Yao
    Jiang, Ying
    Shu, Jian
    [J]. CURRENT MEDICAL IMAGING, 2023, 19 (14) : 1609 - 1615
  • [8] CT features of ulcerative colitis and Crohn's disease
    Gore, RM
    Balthazar, EJ
    Ghahremani, GG
    Miller, FH
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) : 3 - 15
  • [9] Noninvasive assessment of liver fibrosis by dual-layer spectral detector CT
    Morita, Koichiro
    Nishie, Akihiro
    Ushijima, Yasuhiro
    Takayama, Yukihisa
    Fujita, Nobuhiro
    Kubo, Yuichiro
    Ishimatsu, Keisuke
    Yoshizumi, Tomoharu
    Maehara, Junki
    Ishigami, Kousei
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2021, 136
  • [10] SNR performance comparison of dual-layer detector and dual-kVp spectral CT
    Heismann, B. J.
    Wirth, S.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3820 - 3822