Differentiation of Crohn's disease, ulcerative colitis, and intestinal tuberculosis by dual-layer spectral detector CT enterography

被引:1
|
作者
Huang, M. [1 ,2 ]
Tu, L. [3 ]
Li, J. [1 ,2 ]
Yue, X. [1 ,2 ]
Wu, L. [1 ,2 ]
Yang, M. [1 ,2 ]
Chen, Y. [1 ,2 ]
Han, P. [1 ,2 ]
Li, X. [1 ,2 ,5 ]
Zhu, L. [3 ,4 ]
机构
[1] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Radiol, Wuhan, Peoples R China
[2] Hubei Prov Key Lab Mol Imaging, Wuhan, Peoples R China
[3] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Div Gastroenterol, Wuhan, Peoples R China
[4] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Div Gastroenterol, 1277 Jiefang Rd, Wuhan 430022, Hubei Province, Peoples R China
[5] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Radiol, 1277 JieFang Rd, Wuhan 430022, Hubei Province, Peoples R China
关键词
INFLAMMATORY-BOWEL-DISEASE; ENERGY CT; COMPUTED-TOMOGRAPHY; IODINE DENSITY; ACTIVITY INDEX; MANAGEMENT; DIAGNOSIS; CONSENSUS;
D O I
10.1016/j.crad.2023.12.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To investigate the value of radiological features and energy spectrum quantitative parameters in the differential diagnosis of Crohn's disease (CD), ulcerative colitis (UC), and intestinal tuberculosis (ITB) by dual-layer spectral detector computed tomography (CT) enterography (CTE). MATERIALS AND METHODS: Clinical and CTE data were collected from 182 patients with CD, 29 with UC, and 51 with ITB. CT images were obtained at the enteric phases and portal phases. The quantitative energy spectrum parameters were iodine density (ID), normalised ID (NID), virtual non-contrast (VNC) value, and effective atomic number (Z-eff). The area under curve (AUC) of the receiver operating characteristic curve (ROC) was calculated. RESULTS: The vascular comb sign (p=0.0 09) and enlarged lymph nodes (p=0.001) were more common in patients with CD than UC or ITB. In the differentiation of moderate-severe active CD from UC, enteric phase NID (AUC, 0.938; p<0.001) and portal phase Z-eff (AUC, 0.925; p<0.001) had the highest accuracy, which were compared separately. In the differentiation of moderate-severe active CD from ITB, enteric phase NID (AUC, 0.906; p<0.001) and portal phase Z-eff (AUC, 0.947; p<0.001) had the highest accuracy; however, the AUC value was highest when the four parameters are combined (AUC, 0.989; p<0.001; AUC, 0.986; p<0.001; AUC, 0.936; p<0.001; and AUC, 0.986; p<0.001) . CONCLUSION: The present study shows that the combined strategies of four parameters have higher sensitivity and specificity in differentiating CD, UC, and ITB, and may play a key role in guiding treatment. (c) 2023 Published by Elsevier Ltd on behalf of The Royal College of Radiologists.
引用
收藏
页码:e482 / e489
页数:8
相关论文
共 50 条
  • [41] Imaging findings of primary vaginal malignancies by dual-layer spectral detector CT: description of two patients
    Cui, Yuanyuan
    Zhang, Zhengwei
    Zhang, Xiaohui
    Zhao, Baolian
    Shi, Xiaolei
    Zhu, Zhi
    Liu, Xiaojun
    Liu, Shiyuan
    Xiao, Yi
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (01) : 1245 - 1251
  • [42] Is there a link between food and intestinal microbes and the occurrence of Crohn's disease and ulcerative colitis?
    Asakura, Hitoshi
    Suzuki, Kenji
    Kitahora, Tetsuji
    Morizane, Toshio
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2008, 23 (12) : 1794 - 1801
  • [43] Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study
    van Hamersvelt, Robbert W.
    Schilham, Arnold M. R.
    Engelke, Klaus
    den Harder, Annemarie M.
    de Keizer, Bart
    Verhaar, Harald J.
    Leiner, Tim
    de Jong, Pim A.
    Willemink, Martin J.
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (10) : 4351 - 4359
  • [44] Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study
    Robbert W. van Hamersvelt
    Arnold M. R. Schilham
    Klaus Engelke
    Annemarie M. den Harder
    Bart de Keizer
    Harald J. Verhaar
    Tim Leiner
    Pim A. de Jong
    Martin J. Willemink
    [J]. European Radiology, 2017, 27 : 4351 - 4359
  • [45] Diagnosis of benign and malignant thyroid nodules by a dual-layer spectral detector CT-based nomogram
    Yi, Rongqi
    Li, Ting
    Xie, Gang
    Li, Kang
    [J]. FRONTIERS IN ONCOLOGY, 2023, 13
  • [46] Value of dual-layer spectral detector CT in diagnosing regional lymph node metastasis of colorectal cancer
    陈琰
    [J]. China Medical Abstracts (Internal Medicine), 2022, (01) : 2 - 2
  • [47] Value of the virtual monoenergetic image from dual-layer dual-energy computed tomography enterography in the preoperative assessment of the internal penetrating complication of Crohn's disease
    Gong, Meilin
    Liu, Lili
    Ren, Huanhuan
    He, Peipei
    Ran, Xiong
    Xu, Yu
    Zou, Ya
    Wu, Jingsong
    Li, Zan
    Tan, Wei
    Zhang, Zhengying
    Li, Kang
    [J]. ABDOMINAL RADIOLOGY, 2024, 49 (03) : 814 - 822
  • [48] Serologic analysis permits differentiation of Crohn's disease from ulcerative colitis.
    Aisenberg, J
    Zelman, G
    Bodian, C
    Sachar, D
    [J]. GASTROENTEROLOGY, 1998, 114 (04) : A918 - A918
  • [49] IDEA FOR IN VIVO DIFFERENTIATION OF ULCERATIVE COLITIS AND CROHN'S DISEASE WITH CONFOCAL LASER ENDOMICROSCOPY
    Tontini, G. E.
    Mudter, J.
    Vieth, M.
    Atreya, R.
    Guenther, C.
    Zopf, Y.
    Wildner, D.
    Kiesslich, R.
    Pastorelli, L.
    Vecchi, M.
    Neurath, M. F.
    Neumann, H.
    [J]. DIGESTIVE AND LIVER DISEASE, 2014, 46 : S26 - S26
  • [50] Improved Opacification of a Suboptimally Enhanced Pulmonary Artery in Chest CT: Experience Using a Dual-Layer Detector Spectral CT
    Bae, Kyungsoo
    Jeon, Kyung Nyeo
    Cho, Soo Buem
    Park, Sung Eun
    Moon, Jin Il
    Baek, Hye Jin
    Choi, Bo Hwa
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (04) : 734 - 741