Determination of Scattered Radiation to the Thyroid Gland in Dental Cone Beam Computed Tomography

被引:0
|
作者
Hrangkhawl, Wilson [1 ]
Dkhar, Winniecia [1 ,4 ]
Madhavan, T. S. [2 ]
Sharath, S. [1 ]
Vineetha, R. [3 ]
Chhaparwal, Yogesh [3 ]
机构
[1] Manipal Acad Higher Educ, Manipal Coll Hlth Profess, Dept Med Imaging Technol, Manipal, India
[2] Jaipur Natl Univ, Sch Allied Sci, Dept Med Imaging Technol, Jaipur, India
[3] Manipal Acad Higher Educ, Manipal Coll Dent Sci, Dept Oral & Dent Radiol, Manipal, India
[4] Manipal Acad Higher Educ, Manipal Coll Hlth Profess, Dept Med Imaging Technol, Manipal 576104, India
来源
关键词
Cone Beam Computed Tomography; Maxilla; Mandible; Scattered Radiation Dose; Thyroid Gland;
D O I
10.14407/jrpr.2021.00395
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Background: Cone beam computed tomography (CBCT) is a specialized medical equipment and plays a significant role in the diagnosis of oral and maxillofacial diseases and abnormalities; however, it is attributed to risk of exposure of ionizing radiation. The aim of the study was to es-timate and determine the amount of scattered radiation dose to the thyroid gland in dental CBCT during maxilla and mandible scan.Materials and Methods: The average scattered radiation dose for i-CAT 17-19 Platinum CBCT (Imaging Sciences International) was measured using a Multi-O-Meter (Unfors Instru-ments), placed at the patient's neck on the skin surface of the thyroid cartilage, with an exposure parameter of 120 kVp and 37.07 mAs. The surface entrance dose was noted using the Multi-O -Meter, which was placed at the time of the scan at the level of the thyroid gland on the anterior surface of the neck.Results and Discussion: The surface entrance dose to the thyroid from both jaws scans was 191.491 +/- 78.486 mu Gy for 0.25 mm voxel and 26.9 seconds, and 153.670 +/- 74.041 mu Gy from the mandible scan, whereas from the maxilla scan the surface entrance dose was 5.259 +/- 10.691 mu Gy.Conclusion: The surface entrance doses to the thyroid gland from imaging of both the jaws, and also from imaging of the maxilla and mandible alone were within the threshold limit. The surface entrance dose and effective dose in CBCT were dependent on the exposure parameters (kVp and mAs), scan length, and field of view. To further reduce the radiation dose, care should be taken in selecting an appropriate protocol as well as the provision of providing shield-ing to the thyroid gland.
引用
收藏
页码:15 / 19
页数:5
相关论文
共 50 条
  • [41] Comment on "Effective dose range for dental cone beam computed tomography scanners"
    Ludlow, John B.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) : 4219 - 4220
  • [42] In Vitro Detection of Dental Root Fractures with Cone Beam Computed Tomography (CBCT)
    Fisekcioglu, Erdogan
    Dolekoglu, Semanur
    Ilguy, Mehmet
    Ersan, Nilufer
    Ilguy, Dilhan
    IRANIAN JOURNAL OF RADIOLOGY, 2014, 11 (01)
  • [43] Dental students' knowledge and attitudes towards cone beam computed tomography in Turkey
    Kamburoglu, K.
    Kursun, S.
    Akarslan, Z. Z.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (07) : 439 - 443
  • [44] An audit of image quality of three dental cone beam computed tomography units
    Greenall, C. J.
    Thomas, B.
    Drage, N. A.
    Brown, J.
    RADIOGRAPHY, 2016, 22 (01) : 56 - 59
  • [45] Evaluation of Dental Root Fracture Using Cone-beam Computed Tomography
    Wang, Pei
    Yan, Xue Bing
    Liu, Deng Gao
    Zhang, Wan Lin
    Zhang, Zu Yan
    Ma, Xu Chen
    CHINESE JOURNAL OF DENTAL RESEARCH, 2010, 13 (01): : 31 - 35
  • [46] Detection of dental root fractures by using cone-beam computed tomography
    Wang, P.
    Yan, X. B.
    Lui, D. G.
    Zhang, W. L.
    Zhang, Y.
    Ma, X. C.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (05) : 290 - 298
  • [47] Superimposition of a cone beam computed tomography (CBCT) scan and a photograph: A dental technique
    Lee, Soo Young
    Kim, Heechul
    Lee, Doyun
    Park, Chan
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (02): : 212 - 215
  • [48] Location dependency of the spatial resolution of cone beam computed tomography for dental use
    Ozaki, Yoshihiro
    Watanabe, Hiroshi
    Nomura, Yoshikazu
    Honda, Eiichi
    Sumi, Yasunori
    Kurabayashi, Tohru
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (05): : 648 - 655
  • [49] Cone Beam Computed Tomography Imaging in Dental Implants: A Primer for Clinical Radiologists
    Bernaerts, Anja
    Barbier, Lieven
    Abeloos, Johan
    De Backer, Tom
    Bosmans, Frederik
    Vanhoenacker, Filip M.
    Casselman, Jan
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2020, 24 (05) : 499 - 509
  • [50] Cone-beam computed tomography and its applications in dental and maxillofacial radiology
    Schulze, R. K. W.
    Drage, N. A.
    CLINICAL RADIOLOGY, 2020, 75 (09) : 647 - 657