Determination of Scattered Radiation to the Thyroid Gland in Dental Cone Beam Computed Tomography

被引:0
|
作者
Hrangkhawl, Wilson [1 ]
Dkhar, Winniecia [1 ,4 ]
Madhavan, T. S. [2 ]
Sharath, S. [1 ]
Vineetha, R. [3 ]
Chhaparwal, Yogesh [3 ]
机构
[1] Manipal Acad Higher Educ, Manipal Coll Hlth Profess, Dept Med Imaging Technol, Manipal, India
[2] Jaipur Natl Univ, Sch Allied Sci, Dept Med Imaging Technol, Jaipur, India
[3] Manipal Acad Higher Educ, Manipal Coll Dent Sci, Dept Oral & Dent Radiol, Manipal, India
[4] Manipal Acad Higher Educ, Manipal Coll Hlth Profess, Dept Med Imaging Technol, Manipal 576104, India
来源
关键词
Cone Beam Computed Tomography; Maxilla; Mandible; Scattered Radiation Dose; Thyroid Gland;
D O I
10.14407/jrpr.2021.00395
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Background: Cone beam computed tomography (CBCT) is a specialized medical equipment and plays a significant role in the diagnosis of oral and maxillofacial diseases and abnormalities; however, it is attributed to risk of exposure of ionizing radiation. The aim of the study was to es-timate and determine the amount of scattered radiation dose to the thyroid gland in dental CBCT during maxilla and mandible scan.Materials and Methods: The average scattered radiation dose for i-CAT 17-19 Platinum CBCT (Imaging Sciences International) was measured using a Multi-O-Meter (Unfors Instru-ments), placed at the patient's neck on the skin surface of the thyroid cartilage, with an exposure parameter of 120 kVp and 37.07 mAs. The surface entrance dose was noted using the Multi-O -Meter, which was placed at the time of the scan at the level of the thyroid gland on the anterior surface of the neck.Results and Discussion: The surface entrance dose to the thyroid from both jaws scans was 191.491 +/- 78.486 mu Gy for 0.25 mm voxel and 26.9 seconds, and 153.670 +/- 74.041 mu Gy from the mandible scan, whereas from the maxilla scan the surface entrance dose was 5.259 +/- 10.691 mu Gy.Conclusion: The surface entrance doses to the thyroid gland from imaging of both the jaws, and also from imaging of the maxilla and mandible alone were within the threshold limit. The surface entrance dose and effective dose in CBCT were dependent on the exposure parameters (kVp and mAs), scan length, and field of view. To further reduce the radiation dose, care should be taken in selecting an appropriate protocol as well as the provision of providing shield-ing to the thyroid gland.
引用
收藏
页码:15 / 19
页数:5
相关论文
共 50 条
  • [31] Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand
    Neubauer, J.
    Neubauer, C.
    Gerstmair, A.
    Krauss, T.
    Reising, K.
    Zajonc, H.
    Kotter, E.
    Langer, M.
    Fiebich, M.
    Voigt, J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (05): : 488 - 493
  • [32] Operator Radiation Exposure in Cone-Beam Computed Tomography Guidance
    Braak, S. J.
    Van, M. J. L. Strijen
    Meijer, E.
    Van, J. P. M. Heesewijk
    Mali, W. P. Th M.
    JOURNAL OF THE BELGIAN SOCIETY OF RADIOLOGY, 2016, 100 (01):
  • [33] Radiation Dose from Megavoltage Cone Beam Computed Tomography for IGRT
    Kara, E.
    Dirican, B.
    Yazici, A.
    Hicsonmez, A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S810 - S810
  • [34] Imaging dose from cone beam computed tomography in radiation therapy
    Alaei, Parham
    Spezi, Emiliano
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 647 - 658
  • [35] Radiation Dose Estimation From Pediatric Cone Beam Computed Tomography
    Kim, S.
    Yoshizumi, T.
    Toncheva, G.
    Yin, F.
    Frush, D.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [36] The possible usability of three-dimensional cone beam computed dental tomography in dental research
    Yavuz, I.
    Rizal, M. F.
    Kiswanjaya, B.
    1ST PHYSICS AND TECHNOLOGIES IN MEDICINE AND DENTISTRY SYMPOSIUM, 2017, 884
  • [37] Accuracy Analysis of Digital Dental Model Data acquired by Dental Cone Beam Computed Tomography
    Kang, Seen-Young
    Yu, Ji-Min
    Lee, Jun-Seok
    Park, Ki-Sook
    Lee, Seung-Youl
    JOURNAL OF MAGNETICS, 2020, 25 (04) : 663 - 669
  • [38] Cone Beam Computed Tomography in Dental Education: A Survey of US, UK, and Australian Dental Schools
    Parashar, Vijay
    Whaites, Eric
    Monsour, Paul
    Chaudhry, Jahanzeb
    Geist, James R.
    JOURNAL OF DENTAL EDUCATION, 2012, 76 (11) : 1443 - 1447
  • [39] Where does cone beam computed tomography fit into modern dental practice?
    Lam, Ernie
    JOURNAL OF THE CANADIAN DENTAL ASSOCIATION, 2007, 73 (10): : 921 - 923
  • [40] A Phantom Study of a Dual Energy Dental Cone Beam Computed Tomography Prototype
    Chang, Sungho
    Lee, Sang Chul
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,