Detection of dental root fractures by using cone-beam computed tomography

被引:85
|
作者
Wang, P. [1 ,2 ]
Yan, X. B. [3 ,4 ]
Lui, D. G. [1 ,2 ]
Zhang, W. L. [1 ,2 ]
Zhang, Y. [1 ,2 ]
Ma, X. C. [1 ,2 ]
机构
[1] Peking Univ, Dept Oral & Maxillofacial Radiol, Sch Stomatol, Beijing 100081, Peoples R China
[2] Peking Univ, Dept Oral & Maxillofacial Radiol, Hosp Stomatol, Beijing 100081, Peoples R China
[3] Peking Univ, Stomatol Clin 1, Sch Stomatol, Special Dent Dept, Beijing 100081, Peoples R China
[4] Peking Univ, Stomatol Clin 1, Hosp Stomatol, Special Dent Dept, Beijing 100081, Peoples R China
关键词
cone-beam computed tomography; dental radiography; diagnosis; dental root fracture; TREATED TEETH; DIAGNOSIS; CT; RADIOGRAPHY;
D O I
10.1259/dmfr/84907460
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this study was to compare the diagnostic accuracy of cone beam CT (CBCT) with that of conventional dental radiography in the detection of root fractures and to evaluate the influence of root canal fillings on root fracture detection. Methods: We investigated 128 patients with clinically suspected root fractures in 135 teeth. These patients underwent conventional dental radiography, CBCT and eventually surgical exploration. Among the 135 teeth, 86 were non-endodontically treated teeth and 49 were endodontically treated teeth. Two oral radiologists independently analysed the dental radiographs and CBCT images of each patient and reached a consensus. The CBCT findings of root fractures were set as the detection of a separation of the adjacent root segments on at least two contiguous sections and on at least two of the three-dimensional (3D) planes. Results: Root fracture was intraoperatively detected in 95 of the 135 teeth. The sensitivity and specificity of root fractures diagnosed on the basis of the consensus between the 2 evaluators were 26.3% and 100%, respectively, for dental radiography and 89.5% and 97.5%, respectively, for CBCT. CBCT was significantly more accurate than dental radiography in detecting root fractures (P < 0.001). The sensitivity of CBCT was reduced in the presence of root canal fillings but its specificity remained unaffected. Both the sensitivity and specificity of dental radiography were not influenced by the presence of root canal fillings. Conclusions: CBCT appears to be more accurate than conventional dental radiography in the detection of root fractures. Dentomaxillofacial Radiology (2011) 40, 290-298. doi: 10.1259/dmfr/84907460
引用
收藏
页码:290 / 298
页数:9
相关论文
共 50 条
  • [1] Detection of Vertical Root Fractures by Using Cone-beam Computed Tomography: A Clinical Study
    Edlund, Mitchell
    Nair, Madhu K.
    Nair, Umadevi P.
    JOURNAL OF ENDODONTICS, 2011, 37 (06) : 768 - 772
  • [2] Evaluation of Dental Root Fracture Using Cone-beam Computed Tomography
    Wang, Pei
    Yan, Xue Bing
    Liu, Deng Gao
    Zhang, Wan Lin
    Zhang, Zu Yan
    Ma, Xu Chen
    CHINESE JOURNAL OF DENTAL RESEARCH, 2010, 13 (01): : 31 - 35
  • [3] In Vitro Detection of Dental Root Fractures with Cone Beam Computed Tomography (CBCT)
    Fisekcioglu, Erdogan
    Dolekoglu, Semanur
    Ilguy, Mehmet
    Ersan, Nilufer
    Ilguy, Dilhan
    IRANIAN JOURNAL OF RADIOLOGY, 2014, 11 (01)
  • [4] Effect of selecting cone-beam computed tomography for diagnosis of root fractures
    Mizuhashi, Fumi
    Ogura, Ichiro
    Sugawara, Yoshihiro
    Oohashi, Makoto
    Mizuhashi, Ryo
    Saegusa, Hisato
    ORAL SCIENCE INTERNATIONAL, 2021, 18 (03) : 178 - 183
  • [5] Influence of sharpening filters on the detection of root fractures using low-dose cone-beam computed tomography
    Gonzalez, Alexandra Robles
    Tosoni, Guilherme Monteiro
    Freitas, Deborah Queiroz
    Oliveira, Matheus L.
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (07) : 4797 - 4803
  • [6] Influence of sharpening filters on the detection of root fractures using low-dose cone-beam computed tomography
    Alexandra Robles González
    Guilherme Monteiro Tosoni
    Deborah Queiroz Freitas
    Matheus L. Oliveira
    Clinical Oral Investigations, 2022, 26 : 4797 - 4803
  • [7] Diagnosis of root fractures using cone-beam computed tomography: difference of vertical and horizontal root fracture
    Mizuhashi, Fumi
    Ogura, Ichiro
    Sugawara, Yoshihiro
    Oohashi, Makoto
    Mizuhashi, Ryo
    Saegusa, Hisato
    ORAL RADIOLOGY, 2021, 37 (02) : 305 - 310
  • [8] Diagnosis of root fractures using cone-beam computed tomography: difference of vertical and horizontal root fracture
    Fumi Mizuhashi
    Ichiro Ogura
    Yoshihiro Sugawara
    Makoto Oohashi
    Ryo Mizuhashi
    Hisato Saegusa
    Oral Radiology, 2021, 37 : 305 - 310
  • [9] Osteoporosis detection using cone-beam computed tomography
    Geibel, M-A.
    Loeffler, F.
    Kildal, D.
    ORTHOPADE, 2016, 45 (12): : 1066 - 1071
  • [10] Comparison of intraoral radiography and cone-beam computed tomography for the detection of vertical root fractures: an in vitro study
    Gunduz, Kaan
    Avsever, Hakan
    Orhan, Kaan
    Celenk, Peruze
    Ozmen, Bilal
    Cicek, Ersan
    Egrioglu, Erol
    Karacayli, Umit
    ORAL RADIOLOGY, 2013, 29 (01) : 6 - 12