Survival Analysis and Failure Modes of Total Hip Arthroplasty Using a Cemented Semi-Retentive Acetabular Cup

被引:0
|
作者
Stan, Gabriel [1 ]
Roman, Mihai Dan [2 ]
Orban, Horia [1 ]
Georgeanu, Vlad Alexandru [1 ]
Deculescu, Rares Stefan [1 ]
Brinduse, Lacramioara Aurelia [1 ]
Gheorghiu, Nicolae [1 ]
机构
[1] Carol Davila Univ Med & Pharm, Fac Med, Bucharest 050474, Romania
[2] Univ Lucian Blaga Sibiu, Fac Med, Sibiu 550024, Romania
关键词
constrained; dislocation; failure; survival; total hip arthroplasty; FEMORAL-HEAD SIZE; RETROSPECTIVE ANALYSIS; DISLOCATION; REVISION; SURVIVORSHIP; COMPONENTS; LINER; RISK;
D O I
10.3390/jcm12247506
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To reduce the incidence of total hip revisions, there have been continuous efforts to enhance prosthetic materials and designs to optimize implant survival. A primary implant with a constrained acetabular component is often used to minimize the risk of dislocations even though this approach has some drawbacks as reported in the literature. To address these concerns, this study aimed to assess the survivorship and dislocation rate of a semi-retentive cemented acetabular cup when used as a primary implant. The specific cemented cup that we studied was not present in any study that we consulted, so to fill this gap, we conducted a retrospective examination of 527 cemented hip prostheses that utilized the semi-retentive cup between the years 2005 and 2012. We employed Cox multiple regression models for our statistical analysis. The revision due to dislocation occurred in 12.8% of all cases, with a lower incidence of 5% (14 cases) in age groups >70 years than in age groups <70 years (14%-32 cases) (p < 0.001). The survival rates of the semi-retentive cemented acetabular cup were 98.6% (520 cases) at 5 years and 92.2% (487 cases) at 10 years. The survival rates were significantly lower in women than men, with 1.9% (7 cases) toward 0% at 5 years and 8.1% (30 cases) toward 5% (7 cases) at 10 years (p = 0.002). The difference in failure rates between age groups over 70 years (2.3%-10 cases) and age groups under 70 years (11.5%-34 cases) was also statistically significant (p < 0.001). Our study indicates that the semi-constrained design may cause frequent damage to the polyethylene liner due to impingement and wear, which are the primary factors for failure. Also, this implant has a similar risk of revision due to dislocation as reported in studies and may be beneficial as a primary implant in elderly patients with low-demanding lifestyles, muscular insufficiency, and low compliance regarding hip prosthetic behavior, without a major effect on survivorship.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Acetabular cup positioning in revision total hip arthroplasty with Paprosky type III acetabular defects: Martell radiographic analysis
    Choi, Ho-Rim
    Anderson, David
    Foster, Scott
    Beal, Matthew
    Lee, Jo Ann
    Barr, Christopher
    Malchau, Henrik
    McCarthy, Joseph
    Kwon, Young-Min
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (10) : 1905 - 1910
  • [42] A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty
    Aydogan M.
    Burç H.
    Saka G.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (6) : 897 - 903
  • [43] Novel Measure of Acetabular Cup Inclination and Anteversion During Total Hip Arthroplasty
    Walter, William L.
    Baker, Neri A.
    Marsden-Jones, Daniel
    Sadeghpour, Ameneh
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2022, 15 : 1 - 14
  • [44] Constrained Acetabular Liners Cemented Into Cages During Total Hip Revision Arthroplasty
    Khoury, John I.
    Malkani, Arthur L.
    Adler, Edward M.
    Markel, David C.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (06): : 901 - 905
  • [45] Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup
    Hasegawa, M
    Sudo, A
    Hirata, H
    Uchida, A
    JOURNAL OF ARTHROPLASTY, 2003, 18 (05): : 658 - 661
  • [46] Influence of acetabular cup thickness on seating and primary stability in total hip arthroplasty
    Ruhr, Miriam
    Baetz, Johanna
    Pueschel, Klaus
    Morlock, Michael M.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2022, 40 (09) : 2139 - 2146
  • [47] MDCT Image Based Assessment of Acetabular Cup Orientation in Total Hip Arthroplasty
    Kobashi, Syoji
    Iwasa, Kenjiro
    Fujishiro, Takaaki
    Hayashi, Shiya
    Hashimoto, Shingo
    Kuroda, Ryosuke
    Kurosaka, Masahiro
    Kamiura, Naotake
    2014 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS (SMC), 2014, : 2557 - 2562
  • [48] Cemented dual mobility cup for primary total hip arthroplasty: survival and quality of life. A multicenter study
    Rincon, Jairo Alonso
    de la Pava, Camilo
    Velandia, Ruben
    Munoz-Medina, Sofia
    Ferreira, Andre
    SICOT-J, 2025, 11
  • [49] Catastrophic failure and metallosis of the acetabular component in total hip arthroplasty
    Ozan, Firat
    Kahraman, Murat
    Baktir, Ali
    Gencer, Kursat
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [50] Catastrophic failure and metallosis of the acetabular component in total hip arthroplasty
    Fırat Ozan
    Murat Kahraman
    Ali Baktır
    Kürşat Gençer
    Journal of Orthopaedic Surgery and Research, 16