Variable steps least mean square in wind-based standalone distributed generation system for power quality features

被引:1
|
作者
Jagadeesh, Ch. [1 ]
Arya, Sabha Raj [1 ]
机构
[1] Sardar Vallabhbhi Natl Inst Technol, Dept Elect Engn, Dumas Rd, Surat 395007, India
关键词
Distributed generation (DG); DSTATCOM; PMSG; Variable step-size least mean square error (VSSLMS); SIZE; ENERGY; MICROGRIDS; ALGORITHM; DSTATCOM; TRENDS;
D O I
10.1007/s00202-023-02107-8
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Distribution power generation system provides necessary electricity to the emergency services as well as remote located power consumers. The wind energy standalone distributed generator system has benefits of cost effective, quality power generated is introduced in this article to generate a controlled and quality electrical power to the directly connected standalone nonlinear load. The Permanent Magnet Synchronous machine is considered as generator because of its high-speed operation with smooth running characteristics and maintains low noise. DSTATCOM is used to maintain the voltage in all the normal and abnormal conditions and compensate power quality problems such as harmonics, reactive power and load unbalancing. The BESS is included at the DC bus of the DSTATCOM to maintain DC supply power and the load leveling. Type-A, B and C variable step-size least mean square error (VSS-LMS) control algorithms are used to operate the DSTATCOM in all operating conditions. The type-A control is excellent at monitoring the parameters changes of the system in normal and abnormal conditions. Type-B VSS-LMS control has included the another previous value of the error signal to the step signal of Type-A VSSLMS to improve the performance in the signal ripples and obtain a steady-state value. Type-C is introduced to lower the transient time to make the system to reach its steady state very quickly. All these three controls are designed to control the DSTATCOM in standalone DG system using MATLAB and compared these three type of control performance to decide a best control for the system. Type-C VSSLMS control had maintained the terminal voltage at 196 V and it took time of 0.15 s to reach the reference value when it changed from balance system to unbalance system.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Thermodynamic analyses of a standalone diesel-fueled distributed power generation system based on solid oxide fuel cells
    Pan, Zehua
    Shen, Jian
    Wang, Jingyi
    Xu, Xinhai
    Chan, Wei Ping
    Liu, Siyu
    Zhou, Yexin
    Yan, Zilin
    Jiao, Zhenjun
    Lim, Teik-Thye
    Zhong, Zheng
    APPLIED ENERGY, 2022, 308
  • [32] Power quality enhancement of standalone hydropower generation system through modified integrator based observer controlled UPQC
    Sanjenbam, Chandrakala Devi
    Singh, Bhim
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 226
  • [33] Power quality enhancement of standalone hydropower generation system through modified integrator based observer controlled UPQC
    Sanjenbam, Chandrakala Devi
    Singh, Bhim
    Electric Power Systems Research, 2024, 226
  • [34] Low Power Wind Generation System based on Variable Speed Permanent Magnet Synchronous Generators
    Carranza, O.
    Figueres, E.
    Garcera, G.
    Ortega, R.
    Velasco, D.
    2011 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2011,
  • [35] Improved control of wind power generation based on variable structure slide mode and inverse system
    Zhang, Jiyong
    Liu, Guohai
    Li, Jinjie
    International Journal of Control and Automation, 2013, 6 (05): : 277 - 296
  • [36] Generation Scheduling Optimization of Wind-Energy Storage System Based on Wind Power Output Fluctuation Features
    Shi, Jie
    Lee, Wei-Jen
    Liu, Xiaofei
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (01) : 10 - 17
  • [37] Bias-compensated normalised least mean square with variable step size algorithm for three-phase power system frequency estimation
    Ma, Wentao
    Qiu, Jinzhe
    Zhang, Zhiyu
    Zheng, Dongqiao
    Chen, Badong
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (07) : 1040 - 1047
  • [38] Generation Scheduling Optimization of Wind-Energy Storage System Based on Wind Power Output Fluctuation Features
    Shi, Jie
    Lee, Wei-jen
    Liu, Xiaofei
    2017 IEEE/IAS 53RD INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE (I&CPS), 2017,
  • [39] Study of the Optimal Power Output in Variable Speed Wind Power Generation System Based on Switched Reluctance Motor
    Wang, G.
    Zhang, J. W.
    Hu, X. W.
    Zhuo, Z. M.
    2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 1073 - 1077
  • [40] Variable speed wind power generation system based on fuzzy logic control for maximum output power tracking
    Abo-Khalil, AG
    Lee, DC
    Seok, JK
    PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 2039 - 2043