Variable steps least mean square in wind-based standalone distributed generation system for power quality features

被引:1
|
作者
Jagadeesh, Ch. [1 ]
Arya, Sabha Raj [1 ]
机构
[1] Sardar Vallabhbhi Natl Inst Technol, Dept Elect Engn, Dumas Rd, Surat 395007, India
关键词
Distributed generation (DG); DSTATCOM; PMSG; Variable step-size least mean square error (VSSLMS); SIZE; ENERGY; MICROGRIDS; ALGORITHM; DSTATCOM; TRENDS;
D O I
10.1007/s00202-023-02107-8
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Distribution power generation system provides necessary electricity to the emergency services as well as remote located power consumers. The wind energy standalone distributed generator system has benefits of cost effective, quality power generated is introduced in this article to generate a controlled and quality electrical power to the directly connected standalone nonlinear load. The Permanent Magnet Synchronous machine is considered as generator because of its high-speed operation with smooth running characteristics and maintains low noise. DSTATCOM is used to maintain the voltage in all the normal and abnormal conditions and compensate power quality problems such as harmonics, reactive power and load unbalancing. The BESS is included at the DC bus of the DSTATCOM to maintain DC supply power and the load leveling. Type-A, B and C variable step-size least mean square error (VSS-LMS) control algorithms are used to operate the DSTATCOM in all operating conditions. The type-A control is excellent at monitoring the parameters changes of the system in normal and abnormal conditions. Type-B VSS-LMS control has included the another previous value of the error signal to the step signal of Type-A VSSLMS to improve the performance in the signal ripples and obtain a steady-state value. Type-C is introduced to lower the transient time to make the system to reach its steady state very quickly. All these three controls are designed to control the DSTATCOM in standalone DG system using MATLAB and compared these three type of control performance to decide a best control for the system. Type-C VSSLMS control had maintained the terminal voltage at 196 V and it took time of 0.15 s to reach the reference value when it changed from balance system to unbalance system.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Power quality improvement of grid interfaced solar PV system using an improved least mean square-based unified control technique
    Mohapatra, Prerana
    Panda, Anup Kumar
    Venkata Ramana Naik, N.
    Senapati, Laxmidhar
    Behera, Sameer Kumar
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2024, 52 (06) : 2868 - 2888
  • [22] Modified fractional least mean square-based control scheme for dynamic voltage restorer to improve power quality
    Deshpande, Chinmay V.
    Chilipi, Rajasekharareddy
    Arya, Sabha Raj
    ELECTRICAL ENGINEERING, 2024, 106 (04) : 5069 - 5087
  • [23] Adaptive neuro-fuzzy inference system to improve the power quality of variable-speed wind power generation system
    Oguz, Yuksel
    Guney, Irfan
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2010, 18 (04) : 625 - 645
  • [24] Variable step Learning Based Control Algorithm for Power Quality in PMSG Based Power Generation System
    Patel, Ashish
    Arya, Sabha Raj
    Jain, Anjana
    2016 IEEE 7TH POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2016,
  • [25] Feature Extraction Approach for Distributed Wind Power Generation Based on Power System Flexibility Planning Analysis
    Hu, Sile
    Yang, Jiaqiang
    Wang, Yuan
    Chen, Chao
    Nan, Jianan
    Zhao, Yucan
    Bi, Yue
    ELECTRONICS, 2024, 13 (05)
  • [26] Power Dispatching of Distributed Wind-Solar Power Generation Hybrid System Based on Genetic Algorithm
    Li, Min
    Wu, Jie
    Zeng, Jun
    Gao, LaMei
    2009 3RD INTERNATIONAL CONFERENCE ON POWER ELECTRONICS SYSTEMS AND APPLICATIONS: ELECTRIC VEHICLE AND GREEN ENERGY, 2009, : 93 - 93
  • [27] Enhanced power quality based single phase photovoltaic distributed generation system
    Panda, Aurobinda
    Pathak, M. K.
    Srivastava, S. P.
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2016, 103 (08) : 1262 - 1278
  • [28] A distributed fuel cell based generation and compensation system to improve power quality
    Tao, Haimin
    Duarte, Jorge L.
    Hendrix, Marcel A. M.
    IPEMC 2006: CES/IEEE 5TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2006, : 785 - +
  • [29] Variable fractional power-least mean square based control algorithm with optimized PI gains for the operation of dynamic voltage restorer
    Naidu, Talada Appala
    Arya, Sabha Raj
    Maurya, Rakesh
    Sanjeevikumar, P.
    IET POWER ELECTRONICS, 2021, 14 (04) : 821 - 833
  • [30] Broadband Active Sound Quality Control Based on Variable Step Size Filtered-x Normalized Least Mean Square Algorithm
    Liu, Feng
    Mills, James K.
    Dong, Mingming
    Gu, Liang
    2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 1892 - 1896