Measurement of non-invasive cardiac output during cycling exercise in ischemic stroke inpatients: A pilot study

被引:1
|
作者
Yang, Ying [1 ]
Qian, Qiu-Yang [1 ]
Yang, Xiao-Yan [1 ]
Li, De-Sheng [1 ]
Chen, De-Sheng [1 ]
Shen, Mei [1 ]
机构
[1] Peoples Hosp Longhua, Dept Rehabil Med, Shenzhen, Guangdong, Peoples R China
关键词
Cycling training; exercise; ischemic stroke inpatients; non-invasive cardiac output; poststroke cardiac dysfunction; ATRIAL-FIBRILLATION; ABNORMALITIES; COMPLICATIONS; PREVALENCE; DEVICES; IMPACT; ECG;
D O I
10.3233/THC-220823
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Cardiac dysfunction accompanies acute ischemic stroke and affects the effective implementation of early rehabilitation interventions. There is a lack of reference hemodynamic data on cardiac function in the subacute phase of ischemic stroke. OBJECTIVE: In this study, we aimed to identify appropriate cardiac parameters for exercise training utilizing a pilot study. METHODS: We used a transthoracic electrical bioimpedance non-invasive cardiac output measurement (NICOM) device to monitor cardiac function in real time for two groups [i.e., subacute ischemic stroke inpatients group (n = 10) and healthy control group (n = 11)] using a cycling exercise experiment. The parameters of both groups were compared to highlight the cardiac dysfunction in the subacute phase in patients with ischemic stroke. RESULTS: We considered stroke volume index (SVI) and systemic vascular resistance index (SVRi) as the primary outcomes, and there was significant intragroup difference (stroke group: P < 0.001; control group: P < 0.001, using one-way ANOVA) and significant intergroup difference at each individual time segment (P < 0.01, using independent t-test). Among the secondary outcomes, i.e., cardiac index (CI), ejection fraction (EF), end-diastolic volume (EDV), and cardiac contraction index (CTI), we found significant intergroup differences in CI, EF, and CTI scores (P < 0.01, using independent t-test). Significant interaction with respect to time and group were seen only in the SVRi and CI scores (P < 0.01, using two-way ANOVA). There was no significant inter- or intra-group differences in EDV scores. CONCLUSION: SVRI, SVI, and CI values highlight cardiac dysfunction in stroke patients the most. At the same time, these parameters suggest that cardiac dysfunction in stroke patients may be closely related to the increased peripheral vascular resistance caused by infarction and the limitation of myocardial systolic function.
引用
收藏
页码:215 / 228
页数:14
相关论文
共 50 条
  • [31] Do rebreathing manoeuvres for non-invasive measurement of cardiac output during maximum exercise test alter the main cardiopulmonary parameters?
    Vignati, Carlo
    Morosin, Marco
    Fusini, Laura
    Pezzuto, Beatrice
    Spadafora, Emanuele
    De Martino, Fabiana
    Salvioni, Elisabetta
    Rovai, Sara
    Filardi, Pasquale P.
    Sinagra, Gianfranco
    Agostoni, Piergiuseppe
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2019, 26 (15) : 1616 - 1622
  • [32] Test-Retest Reliability of Non-Invasive Cardiac Output Measurement during Exercise in Healthy Volunteers in Daily Clinical Routine
    Barroso, Michael Thomas Coll
    Hoppe, Matthias Wilhelm
    Boehme, Philip
    Krahn, Thomas
    Kiefer, Christian
    Kramer, Frank
    Mondritzki, Thomas
    Pirez, Phillipe
    Dinh, Wilfried
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2019, 113 (02) : 231 - 239
  • [33] Predicting Peak Cardiac Output Using A Non-invasive Measurement At Submaximal And Post-maximal Exercise
    Babcock, Carmen J.
    Ghizzoni, Shannon
    Kirby, Timothy E.
    Devor, Steven T.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S99 - S100
  • [34] Non-invasive cardiac output monitoring
    Huber, T
    Segiet, W
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1997, 38 (05): : 233 - 244
  • [35] Non-invasive cardiac output monitoring during sinus surgery
    Gollapudy, Suneeta
    Riess, Matthias L.
    JOURNAL OF ANESTHESIA, 2015, 29 (04) : 639 - 639
  • [36] Non-invasive cardiac output monitoring during sinus surgery
    Suneeta Gollapudy
    Matthias L. Riess
    Journal of Anesthesia, 2015, 29 : 639 - 639
  • [37] Non-invasive assessment of cardiac output during stress test
    Di Tante, V
    Romano, M
    Gensini, G
    Guerrisi, A
    Galanti, G
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05): : S27 - S27
  • [38] Non-invasive measurement of cardiac output and ventricular ejection fractions in chronic cardiac failure: Relationship to impaired exercise tolerance
    Steele, IC
    Moore, A
    Nugent, AM
    Riley, MS
    Campbell, NPS
    Nicholls, DP
    CLINICAL SCIENCE, 1997, 93 (03) : 195 - 203
  • [39] A non-invasive cardiac output measurement as an alternative to the test bolus technique during CT angiography
    Nijhof, W. H.
    Hilbink, M.
    Jager, G. J.
    Slump, C. H.
    Rutten, M. J. C. M.
    CLINICAL RADIOLOGY, 2016, 71 (09) : 940.e1 - 940.e5
  • [40] Measurement of cardiac output with non-invasive Aesculon® impedance versus thermodilution
    Petter, Hedelin
    Erik, Agger
    Bjorn, Ekmehag
    Goran, Radegran
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2011, 31 (01) : 39 - 47