Measurement of non-invasive cardiac output during cycling exercise in ischemic stroke inpatients: A pilot study

被引:1
|
作者
Yang, Ying [1 ]
Qian, Qiu-Yang [1 ]
Yang, Xiao-Yan [1 ]
Li, De-Sheng [1 ]
Chen, De-Sheng [1 ]
Shen, Mei [1 ]
机构
[1] Peoples Hosp Longhua, Dept Rehabil Med, Shenzhen, Guangdong, Peoples R China
关键词
Cycling training; exercise; ischemic stroke inpatients; non-invasive cardiac output; poststroke cardiac dysfunction; ATRIAL-FIBRILLATION; ABNORMALITIES; COMPLICATIONS; PREVALENCE; DEVICES; IMPACT; ECG;
D O I
10.3233/THC-220823
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Cardiac dysfunction accompanies acute ischemic stroke and affects the effective implementation of early rehabilitation interventions. There is a lack of reference hemodynamic data on cardiac function in the subacute phase of ischemic stroke. OBJECTIVE: In this study, we aimed to identify appropriate cardiac parameters for exercise training utilizing a pilot study. METHODS: We used a transthoracic electrical bioimpedance non-invasive cardiac output measurement (NICOM) device to monitor cardiac function in real time for two groups [i.e., subacute ischemic stroke inpatients group (n = 10) and healthy control group (n = 11)] using a cycling exercise experiment. The parameters of both groups were compared to highlight the cardiac dysfunction in the subacute phase in patients with ischemic stroke. RESULTS: We considered stroke volume index (SVI) and systemic vascular resistance index (SVRi) as the primary outcomes, and there was significant intragroup difference (stroke group: P < 0.001; control group: P < 0.001, using one-way ANOVA) and significant intergroup difference at each individual time segment (P < 0.01, using independent t-test). Among the secondary outcomes, i.e., cardiac index (CI), ejection fraction (EF), end-diastolic volume (EDV), and cardiac contraction index (CTI), we found significant intergroup differences in CI, EF, and CTI scores (P < 0.01, using independent t-test). Significant interaction with respect to time and group were seen only in the SVRi and CI scores (P < 0.01, using two-way ANOVA). There was no significant inter- or intra-group differences in EDV scores. CONCLUSION: SVRI, SVI, and CI values highlight cardiac dysfunction in stroke patients the most. At the same time, these parameters suggest that cardiac dysfunction in stroke patients may be closely related to the increased peripheral vascular resistance caused by infarction and the limitation of myocardial systolic function.
引用
收藏
页码:215 / 228
页数:14
相关论文
共 50 条
  • [21] NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT BY ULTRASONIC METHODS
    TERUYA, H
    IWAHASHI, K
    KUREHA, M
    NAKAYAMA, N
    KUNO, A
    NAKATSUKA, T
    YOSHIMURA, S
    FURUHATA, H
    HORISAKA, R
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1981, 45 (08): : 942 - 942
  • [22] End Tidal Oxygen: A Non-Invasive Measurement of Cardiac Output
    Singer, D. J.
    Russell, J.
    Caputo, N.
    ANNALS OF EMERGENCY MEDICINE, 2019, 74 (04) : S138 - S138
  • [23] NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT USING ULTRASOUND
    SKIDMORE, R
    WILKINSON, PR
    REES, JR
    WELLS, PNT
    ULTRASONIC IMAGING, 1982, 4 (02) : 195 - 195
  • [24] NON-INVASIVE CARDIAC-OUTPUT MEASUREMENT BY BIOIMPEDANCE - IS IT RELIABLE
    JEWKES, C
    VERHOEFF, F
    SEAR, JW
    FOEX, P
    BRITISH JOURNAL OF ANAESTHESIA, 1989, 63 (05) : P619 - P619
  • [25] Reliability of non-invasive cardiac output measurement in individuals with tetraplegia
    Hostettler, S.
    Brechbuehl, J.
    Leuthold, L.
    Mueller, G.
    Illi, S. K.
    Spengler, C. M.
    SPINAL CORD, 2011, 49 (05) : 665 - 671
  • [26] Non-invasive measurement of cardiac output by Finometer in patients with cirrhosis
    Kaltoft, N.
    Hobolth, L.
    Moller, S.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2010, 30 (04) : 230 - 233
  • [27] Study to investigate the correlation between non-invasive cardiac output monitoring and oxygen consumption during exercise testing
    Wood, J.
    Bryan, A.
    Moore, J. A.
    Benington, S.
    Parker, M.
    Gall, I.
    Jepegnanam, C.
    Foster, P. N.
    Atkinson, D.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (05) : 875 - 876
  • [28] The non-invasive and continuous estimation of cardiac output using a photoplethysmogram and electrocardiogram during incremental exercise
    Wang, L.
    Poon, C. C. Y.
    Zhang, Y. T.
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (05) : 715 - 726
  • [29] STUDY OF NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT BY DOPPLER ULTRASONIC FLOWMETER (2) - WITH SPECIAL REFERENCE TO CARDIAC FUNCTION TEST BY EXERCISE
    KOIKE, M
    TAKAHASH.T
    YOSHIMUR.S
    YOSHIDA, A
    NAKATSUK.T
    HAYASHI, T
    MURAOKA, K
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1973, 37 (06): : 605 - 605
  • [30] Monitoring non-invasive cardiac output and stroke volume during experimental human hypovolaemia and resuscitation
    Reisner, A. T.
    Xu, D.
    Ryan, K. L.
    Convertino, V. A.
    Rickards, C. A.
    Mukkamala, R.
    BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (01) : 23 - 30