Do rebreathing manoeuvres for non-invasive measurement of cardiac output during maximum exercise test alter the main cardiopulmonary parameters?

被引:10
|
作者
Vignati, Carlo [1 ,2 ]
Morosin, Marco [1 ,3 ]
Fusini, Laura [1 ]
Pezzuto, Beatrice [1 ]
Spadafora, Emanuele [1 ]
De Martino, Fabiana [1 ]
Salvioni, Elisabetta [1 ]
Rovai, Sara [1 ,4 ]
Filardi, Pasquale P. [5 ]
Sinagra, Gianfranco [3 ]
Agostoni, Piergiuseppe [1 ,2 ]
机构
[1] IRCCS, Ctr Cardiol Monzino, Via Parea 4, I-20138 Milan, Italy
[2] Univ Milan, Dept Clin Sci & Community Hlth, Milan, Italy
[3] Azienda Sanitaria Univ Integrata Trieste, Cardiovasc Dept, Trieste, Italy
[4] Univ Padua, Padua, Italy
[5] Federico II Univ Naples, Dept Adv Biomed Sci, Naples, Italy
关键词
Cardiac output; cardiopulmonary exercise test; inert gas rebreathing; HEART-FAILURE PATIENTS; VENTILATORY RESPONSE; PEAK EXERCISE; INCREASE; VOLUME; FLOW;
D O I
10.1177/2047487319845967
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Inert gas rebreathing has been recently described as an emergent reliable non-invasive method for cardiac output determination during exercise, allowing a relevant improvement of cardiopulmonary exercise test clinical relevance. For cardiac output measurements by inert gas rebreathing, specific respiratory manoeuvres are needed which might affect pivotal cardiopulmonary exercise test parameters, such as exercise tolerance, oxygen uptake and ventilation vs carbon dioxide output (VE/VCO2) relationship slope. Method We retrospectively analysed cardiopulmonary exercise testing of 181 heart failure patients who underwent both cardiopulmonary exercise testing and cardiopulmonary exercise test+cardiac output within two months (average 16 +/- 15 days). All patients were in stable clinical conditions (New York Heart Association I-III) and on optimal medical therapy. Results The majority of patients were in New York Heart Association Class I and II (78.8%), with a mean left ventricular ejection fraction of 31 +/- 10%. No difference was found between the two tests in oxygen uptake at peak exercise (1101 (interquartile range 870-1418) ml/min at cardiopulmonary exercise test vs 1103 (844-1389) at cardiopulmonary exercise test-cardiac output) and at anaerobic threshold. However, anaerobic threshold and peak heart rate, peak workload (75 (58-101) watts and 64 (42-90), p < 0.01) and carbon dioxide output were significantly higher at cardiopulmonary exercise testing than at cardiopulmonary exercise test+cardiac output, whereas VE/VCO2 slope was higher at cardiopulmonary exercise test+cardiac output (30 (27-35) vs 33 (28-37), p < 0.01). Conclusion The similar anaerobic threshold and peak oxygen uptake in the two tests with a lower peak workload and higher VE/VCO2 slope at cardiopulmonary exercise test+cardiac output suggest a higher respiratory work and consequent demand for respiratory muscle blood flow secondary to the ventilatory manoeuvres. Accordingly, VE/VCO2 slope and peak workload must be evaluated with caution during cardiopulmonary exercise test+cardiac output.
引用
收藏
页码:1616 / 1622
页数:7
相关论文
共 50 条
  • [1] Do Maximum Flow-Volume Loops Collected During Maximum Exercise Test Alter the Main Cardiopulmonary Parameters?
    Bussotti, Maurizio
    Agostoni, PierGiuseppe
    Durigato, Alberto
    Santoriello, Carlo
    Farina, Stefania
    Brusasco, Vito
    Pellegrino, Riccardo
    CHEST, 2009, 135 (02) : 425 - 433
  • [2] Non-Invasive Cardiac Output Measurement Using Inert Gas Rebreathing Method during Cardiopulmonary Exercise Testing-A Systematic Review
    Chwiedz, Agnieszka
    Minarowski, Lukasz
    Mroz, Robert M.
    Hady, Hady Razak
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (22)
  • [3] The impact of pulmonary parameters on non-invasive measurement of cardiac output by the inert gas rebreathing method
    Saur, J.
    Trinkmann, F.
    Doesch, C.
    Papavassiliu, T.
    Scherhag, A.
    Schoenberg, S. O.
    Borggrefe, M.
    Kaden, J. J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 595 - 596
  • [4] Non-invasive cardiac output evaluation during progressive exercise test
    Richard, R
    Lonsdorfer-Wolf, E
    Charloux, A
    Oswald-Mammoser, M
    Mettauer, B
    Lampert, E
    Lonsdorfer, J
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2000, 440 (06): : R268 - R268
  • [5] Functional evaluation of resynchronization therapy by means of non invasive cardiac output measurement during cardiopulmonary exercise test
    Vignati, C. Carlo
    Scoccia, A.
    Cattadori, G.
    Salvioni, E.
    Farina, S.
    Agostoni, P.
    EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 445 - 445
  • [6] NON-INVASIVE CARDIAC-OUTPUT MONITORING DURING EXERCISE STRESS TEST
    NANNA, M
    CHANDRARATNA, PAN
    NIMALASURIYA, A
    KAWANISHI, D
    MCKAY, C
    KOTLEWSKI, A
    RAHIMTOOLA, S
    CIRCULATION, 1983, 68 (04) : 10 - 10
  • [7] Non-invasive cardiac output assessment during moderate exercise:: pulse contour compared with CO2 rebreathing
    Houtman, S
    Oeseburg, B
    Hopman, MTE
    CLINICAL PHYSIOLOGY, 1999, 19 (03): : 230 - 237
  • [8] Non-invasive assessment of cardiac output during stress test
    Di Tante, V
    Romano, M
    Gensini, G
    Guerrisi, A
    Galanti, G
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05): : S27 - S27
  • [9] NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT DURING LAPAROSCOPY
    MCKENZIE, R
    WADHWA, RK
    BEDGER, RC
    JOURNAL OF REPRODUCTIVE MEDICINE, 1980, 24 (06) : 247 - 250
  • [10] Addressing Assumptions for the Use of Non-invasive Cardiac Output Measurement Techniques During Exercise in COPD
    Perrault, Helene
    Richard, Ruddy
    Kapchinsky, Sophia
    Baril, Jacinthe
    Bourbeau, Jean
    Taivassalo, Tanja
    COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2016, 13 (01) : 75 - 81