Addressing Assumptions for the Use of Non-invasive Cardiac Output Measurement Techniques During Exercise in COPD

被引:4
|
作者
Perrault, Helene [1 ,2 ]
Richard, Ruddy [2 ,3 ,4 ]
Kapchinsky, Sophia [2 ,5 ]
Baril, Jacinthe [2 ]
Bourbeau, Jean [2 ]
Taivassalo, Tanja [2 ,5 ]
机构
[1] Univ Ottawa, Fac Hlth Sci, Ottawa, ON, Canada
[2] McGill Univ, Ctr Hlth, Montreal Chest Inst, Resp & Epidemiol Clin Res Unit, Montreal, PQ H2W 1S4, Canada
[3] CHU, Dept Sport Med & Funct Explorat, Clermont Ferrand, France
[4] INRA, UMR 1019, Clermont Ferrand, France
[5] McGill Univ, Dept Kinesiol & Phys Educ, Montreal, PQ, Canada
关键词
bioimpedance; exercise testing; soluble gas; ventilation:perfusion; OBSTRUCTIVE PULMONARY-DISEASE; IMPEDANCE CARDIOGRAPH DEVICE; MAXIMAL AEROBIC EXERCISE; HEART-FAILURE PATIENTS; DIRECT FICK METHOD; REBREATHING METHOD; VALIDITY; REST; RELIABILITY;
D O I
10.3109/15412555.2015.1043985
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The multifactorial functional limitation of COPD increasingly demonstrates the need for an integrated circulatory assessment. In this study cardiac output (Qc) derived from non-inert (CO2-RB), inert (N2O-RB) gas rebreathing approaches and bioimpedance were compared to examine the limitations of currently available non-invasive techniques for exercise Qc determination in patients with chronic lung disease. Thirteen COPD patients (GOLD II-III) completed three constant cycling bouts at 20, 35, and 50% of peak work on two occasions to assess Qc with bioimpedance as well as using CO2-RB and N2O-RB for all exercise tests. Results showed significantly lower Qc using the N2O-RB or end-tidal CO2-derived Qc compared to the PaCO2-derived CO2-RB or the bioimpedance at rest and for all exercise intensities. End-tidal CO2-derived values are however not statistically different from those obtained using inert-gas rebreathing. This study show that in COPD patients, CO2-rebreathing Qc values obtained using PaCO2 contents which account for any gas exchange impairment or inadequate gas mixing are similar to those obtained using thoracic bioimpedance. Alternately, the lower values for N2O rebreathing derived Qc indicates the inability of this technique to account for gas exchange impairment in the computation of Qc. These findings indicate that the choice of a gas rebreathing technique to measure Qc in patients must be dictated by the ability to include in the derived computations a correction for either gas exchange inadequacies and/or a vascular shunt.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 50 条
  • [1] NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT DURING LAPAROSCOPY
    MCKENZIE, R
    WADHWA, RK
    BEDGER, RC
    JOURNAL OF REPRODUCTIVE MEDICINE, 1980, 24 (06) : 247 - 250
  • [2] Non-invasive cardiac output evaluation during progressive exercise test
    Richard, R
    Lonsdorfer-Wolf, E
    Charloux, A
    Oswald-Mammoser, M
    Mettauer, B
    Lampert, E
    Lonsdorfer, J
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2000, 440 (06): : R268 - R268
  • [3] Model for non-invasive cardiac output measurement
    Wassertheurer, Siegfried
    Mayer, Christopher
    Breitenecker, Felix
    AMS 2007: FIRST ASIA INTERNATIONAL CONFERENCE ON MODELLING & SIMULATION ASIA MODELLING SYMPOSIUM, PROCEEDINGS, 2007, : 580 - +
  • [4] NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT
    LASZLO, G
    BOONZAIER, D
    WELLS, PNT
    BIOMEDICAL ENGINEERING, 1974, 9 (08): : 362 - 364
  • [5] NON-INVASIVE CARDIAC-OUTPUT MEASUREMENT
    MACKAY, RS
    MICROVASCULAR RESEARCH, 1972, 4 (04) : 438 - &
  • [6] THE USE OF DOPPLER ULTRASOUND IN THE NON-INVASIVE MEASUREMENT OF CARDIAC-OUTPUT
    EVANS, JM
    SKIDMORE, R
    BAKER, JD
    WELLS, PNT
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (726): : 542 - 542
  • [7] The Use of Non-invasive Ventilation during Exercise Training in COPD Patients
    Ambrosino, Nicolino
    Xie, Lixin
    COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2017, 14 (04) : 396 - 400
  • [8] Measurement of non-invasive cardiac output during cycling exercise in ischemic stroke inpatients: A pilot study
    Yang, Ying
    Qian, Qiu-Yang
    Yang, Xiao-Yan
    Li, De-Sheng
    Chen, De-Sheng
    Shen, Mei
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (01) : 215 - 228
  • [9] Non-invasive cardiac output monitoring techniques in the ICU
    Kerstens, M. K.
    Wijnberge, M.
    Geerts, B. F.
    Vlaar, A. P.
    Veelo, D. P.
    NETHERLANDS JOURNAL OF CRITICAL CARE, 2018, 26 (03): : 104 - 110
  • [10] Non-invasive assessment of cardiac output at rest and during exercise by finger plethysmography
    Critoph, Christopher H.
    Patel, Vimal
    Mist, Bryan
    Thomas, Martin D.
    Elliott, Perry M.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2013, 33 (05) : 338 - 343