Addressing Assumptions for the Use of Non-invasive Cardiac Output Measurement Techniques During Exercise in COPD

被引:4
|
作者
Perrault, Helene [1 ,2 ]
Richard, Ruddy [2 ,3 ,4 ]
Kapchinsky, Sophia [2 ,5 ]
Baril, Jacinthe [2 ]
Bourbeau, Jean [2 ]
Taivassalo, Tanja [2 ,5 ]
机构
[1] Univ Ottawa, Fac Hlth Sci, Ottawa, ON, Canada
[2] McGill Univ, Ctr Hlth, Montreal Chest Inst, Resp & Epidemiol Clin Res Unit, Montreal, PQ H2W 1S4, Canada
[3] CHU, Dept Sport Med & Funct Explorat, Clermont Ferrand, France
[4] INRA, UMR 1019, Clermont Ferrand, France
[5] McGill Univ, Dept Kinesiol & Phys Educ, Montreal, PQ, Canada
关键词
bioimpedance; exercise testing; soluble gas; ventilation:perfusion; OBSTRUCTIVE PULMONARY-DISEASE; IMPEDANCE CARDIOGRAPH DEVICE; MAXIMAL AEROBIC EXERCISE; HEART-FAILURE PATIENTS; DIRECT FICK METHOD; REBREATHING METHOD; VALIDITY; REST; RELIABILITY;
D O I
10.3109/15412555.2015.1043985
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The multifactorial functional limitation of COPD increasingly demonstrates the need for an integrated circulatory assessment. In this study cardiac output (Qc) derived from non-inert (CO2-RB), inert (N2O-RB) gas rebreathing approaches and bioimpedance were compared to examine the limitations of currently available non-invasive techniques for exercise Qc determination in patients with chronic lung disease. Thirteen COPD patients (GOLD II-III) completed three constant cycling bouts at 20, 35, and 50% of peak work on two occasions to assess Qc with bioimpedance as well as using CO2-RB and N2O-RB for all exercise tests. Results showed significantly lower Qc using the N2O-RB or end-tidal CO2-derived Qc compared to the PaCO2-derived CO2-RB or the bioimpedance at rest and for all exercise intensities. End-tidal CO2-derived values are however not statistically different from those obtained using inert-gas rebreathing. This study show that in COPD patients, CO2-rebreathing Qc values obtained using PaCO2 contents which account for any gas exchange impairment or inadequate gas mixing are similar to those obtained using thoracic bioimpedance. Alternately, the lower values for N2O rebreathing derived Qc indicates the inability of this technique to account for gas exchange impairment in the computation of Qc. These findings indicate that the choice of a gas rebreathing technique to measure Qc in patients must be dictated by the ability to include in the derived computations a correction for either gas exchange inadequacies and/or a vascular shunt.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 50 条
  • [31] Test-Retest Reliability of Non-Invasive Cardiac Output Measurement during Exercise in Healthy Volunteers in Daily Clinical Routine
    Barroso, Michael Thomas Coll
    Hoppe, Matthias Wilhelm
    Boehme, Philip
    Krahn, Thomas
    Kiefer, Christian
    Kramer, Frank
    Mondritzki, Thomas
    Pirez, Phillipe
    Dinh, Wilfried
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2019, 113 (02) : 231 - 239
  • [32] Predicting Peak Cardiac Output Using A Non-invasive Measurement At Submaximal And Post-maximal Exercise
    Babcock, Carmen J.
    Ghizzoni, Shannon
    Kirby, Timothy E.
    Devor, Steven T.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S99 - S100
  • [33] Non-invasive cardiac output monitoring
    Huber, T
    Segiet, W
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1997, 38 (05): : 233 - 244
  • [34] Non-invasive cardiac output monitoring during sinus surgery
    Gollapudy, Suneeta
    Riess, Matthias L.
    JOURNAL OF ANESTHESIA, 2015, 29 (04) : 639 - 639
  • [35] Non-invasive cardiac output monitoring during sinus surgery
    Suneeta Gollapudy
    Matthias L. Riess
    Journal of Anesthesia, 2015, 29 : 639 - 639
  • [36] Non-invasive assessment of cardiac output during stress test
    Di Tante, V
    Romano, M
    Gensini, G
    Guerrisi, A
    Galanti, G
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05): : S27 - S27
  • [37] Non-invasive measurement of cardiac output and ventricular ejection fractions in chronic cardiac failure: Relationship to impaired exercise tolerance
    Steele, IC
    Moore, A
    Nugent, AM
    Riley, MS
    Campbell, NPS
    Nicholls, DP
    CLINICAL SCIENCE, 1997, 93 (03) : 195 - 203
  • [38] A non-invasive cardiac output measurement as an alternative to the test bolus technique during CT angiography
    Nijhof, W. H.
    Hilbink, M.
    Jager, G. J.
    Slump, C. H.
    Rutten, M. J. C. M.
    CLINICAL RADIOLOGY, 2016, 71 (09) : 940.e1 - 940.e5
  • [39] Measurement of cardiac output with non-invasive Aesculon® impedance versus thermodilution
    Petter, Hedelin
    Erik, Agger
    Bjorn, Ekmehag
    Goran, Radegran
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2011, 31 (01) : 39 - 47
  • [40] Non-invasive measurement of cardiac output in patients with chronic heart failure
    Leslie, SJ
    McKee, S
    Newby, DE
    Webb, DJ
    Denvir, MA
    BLOOD PRESSURE MONITORING, 2004, 9 (05) : 277 - 280