Do rebreathing manoeuvres for non-invasive measurement of cardiac output during maximum exercise test alter the main cardiopulmonary parameters?

被引:10
|
作者
Vignati, Carlo [1 ,2 ]
Morosin, Marco [1 ,3 ]
Fusini, Laura [1 ]
Pezzuto, Beatrice [1 ]
Spadafora, Emanuele [1 ]
De Martino, Fabiana [1 ]
Salvioni, Elisabetta [1 ]
Rovai, Sara [1 ,4 ]
Filardi, Pasquale P. [5 ]
Sinagra, Gianfranco [3 ]
Agostoni, Piergiuseppe [1 ,2 ]
机构
[1] IRCCS, Ctr Cardiol Monzino, Via Parea 4, I-20138 Milan, Italy
[2] Univ Milan, Dept Clin Sci & Community Hlth, Milan, Italy
[3] Azienda Sanitaria Univ Integrata Trieste, Cardiovasc Dept, Trieste, Italy
[4] Univ Padua, Padua, Italy
[5] Federico II Univ Naples, Dept Adv Biomed Sci, Naples, Italy
关键词
Cardiac output; cardiopulmonary exercise test; inert gas rebreathing; HEART-FAILURE PATIENTS; VENTILATORY RESPONSE; PEAK EXERCISE; INCREASE; VOLUME; FLOW;
D O I
10.1177/2047487319845967
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Inert gas rebreathing has been recently described as an emergent reliable non-invasive method for cardiac output determination during exercise, allowing a relevant improvement of cardiopulmonary exercise test clinical relevance. For cardiac output measurements by inert gas rebreathing, specific respiratory manoeuvres are needed which might affect pivotal cardiopulmonary exercise test parameters, such as exercise tolerance, oxygen uptake and ventilation vs carbon dioxide output (VE/VCO2) relationship slope. Method We retrospectively analysed cardiopulmonary exercise testing of 181 heart failure patients who underwent both cardiopulmonary exercise testing and cardiopulmonary exercise test+cardiac output within two months (average 16 +/- 15 days). All patients were in stable clinical conditions (New York Heart Association I-III) and on optimal medical therapy. Results The majority of patients were in New York Heart Association Class I and II (78.8%), with a mean left ventricular ejection fraction of 31 +/- 10%. No difference was found between the two tests in oxygen uptake at peak exercise (1101 (interquartile range 870-1418) ml/min at cardiopulmonary exercise test vs 1103 (844-1389) at cardiopulmonary exercise test-cardiac output) and at anaerobic threshold. However, anaerobic threshold and peak heart rate, peak workload (75 (58-101) watts and 64 (42-90), p < 0.01) and carbon dioxide output were significantly higher at cardiopulmonary exercise testing than at cardiopulmonary exercise test+cardiac output, whereas VE/VCO2 slope was higher at cardiopulmonary exercise test+cardiac output (30 (27-35) vs 33 (28-37), p < 0.01). Conclusion The similar anaerobic threshold and peak oxygen uptake in the two tests with a lower peak workload and higher VE/VCO2 slope at cardiopulmonary exercise test+cardiac output suggest a higher respiratory work and consequent demand for respiratory muscle blood flow secondary to the ventilatory manoeuvres. Accordingly, VE/VCO2 slope and peak workload must be evaluated with caution during cardiopulmonary exercise test+cardiac output.
引用
收藏
页码:1616 / 1622
页数:7
相关论文
共 50 条
  • [21] Partial CO2 rebreathing indirect fick technique for non-invasive measurement of cardiac output
    Haryadi, DG
    Orr, JA
    Kuck, K
    McJames, S
    Westenskow, DR
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2000, 16 (5-6) : 361 - 374
  • [22] Measurement of non-invasive cardiac output during cycling exercise in ischemic stroke inpatients: A pilot study
    Yang, Ying
    Qian, Qiu-Yang
    Yang, Xiao-Yan
    Li, De-Sheng
    Chen, De-Sheng
    Shen, Mei
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (01) : 215 - 228
  • [23] Non-invasive cardiac output monitoring after cardiopulmonary exercise testing in patients with heart failure
    Sawicka, E. Emilia
    Marcinkiewicz-Siemion, M.
    Ptaszynska-Kopczynska, K.
    Lapinska, M.
    Szpakowicz, M.
    Skawronska, J.
    Musial, W. J.
    Kaminski, K. A.
    EUROPEAN JOURNAL OF HEART FAILURE, 2017, 19 : 72 - 72
  • [24] Non-invasive assessment of cardiac output at rest and during exercise by finger plethysmography
    Critoph, Christopher H.
    Patel, Vimal
    Mist, Bryan
    Thomas, Martin D.
    Elliott, Perry M.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2013, 33 (05) : 338 - 343
  • [25] EVALUATION OF THE CO2 REBREATHING METHOD FOR THE NON-INVASIVE MEASUREMENT OF RESTING CARDIAC-OUTPUT IN MAN
    HARGREAVES, M
    JENNINGS, G
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1983, 10 (05) : 609 - 614
  • [26] Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique
    Gabrielsen, A
    Videbæk, R
    Schou, M
    Damgaard, M
    Kastrup, J
    Norsk, P
    CLINICAL SCIENCE, 2002, 102 (02) : 247 - 252
  • [27] A novel approach to non-invasive measurement of cardiac output
    Klein, Michael
    Machina, Matt
    Battisti, Anne
    Pucci, Olivia
    Minkovich, Leonid
    Duffin, James
    Fisher, Joseph
    FASEB JOURNAL, 2011, 25
  • [28] NON-INVASIVE DOPPLER MEASUREMENT OF CARDIAC-OUTPUT
    TOUCHE, T
    NITENBERG, A
    LAFFAY, N
    DAHAN, M
    PRASQUIER, R
    PRESSE MEDICALE, 1984, 13 (27): : 1687 - 1692
  • [29] NON-INVASIVE METHOD FOR THE MEASUREMENT OF CARDIAC-OUTPUT
    NARUMI, J
    SUMA, K
    OHE, Y
    IWABUCHI, K
    UCHIYAMA, A
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1982, 46 (08): : 801 - 802
  • [30] Non-invasive measurement of intrapulmonary shunt during inert gas rebreathing
    Peyton, PJ
    Poustie, SJ
    Robinson, GJB
    Penny, DJ
    Thompson, B
    PHYSIOLOGICAL MEASUREMENT, 2005, 26 (03) : 309 - 316