Uncommon causes of hemoglobin E flags identified during measurement of hemoglobin A1c by ion-exchange high-performance liquid chromatography

被引:0
|
作者
Herb, Thomas [1 ]
Taylor, Alexander S. [1 ]
Li, Shih-Hon [1 ]
Manthei, David M. [1 ]
Gherasim, Carmen [1 ]
机构
[1] Univ Michigan, Dept Pathol, Ann Arbor, MI 48109 USA
关键词
hemoglobin Hoshida; hemoglobin E; hemoglobin A1c; interference; hemoglobin variant; HPLC; clinical chemistry; VARIANTS; MANAGEMENT; VALUES; ASSAYS;
D O I
10.1093/labmed/lmad113
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We present 3 cases of discordant results from screening hemoglobin A1c (HbA1c) measured by ion-exchange high-performance liquid chromatography (HPLC) all due to various forms of interference and flagged by the instrument as "suspected hemoglobin E (HbE)." The first case was due to a rare hemoglobin variant, later confirmed to be hemoglobin Hoshida, the second due to "true" heterozygous HbE, and the third a result of analytical artifact causing splitting of the HbA1c peak without an underlying variant hemoglobin. We examine the similarities in these cases along with the laboratory work-up to classify each cause of interference to demonstrate the wide array of potential causes for the suspected HbE flag and why it warrants proper work-up. Because there is no standardized method of reporting out hemoglobin variant interference in HbA1c measurement, we discuss our laboratory's process of investigating discordant HbA1c measurements and reporting results in cases with variant interference as 1 possible model to follow, along with discussing the associated laboratory, ethical, and clinical considerations. We also examine the structure of hemoglobin Hoshida, HbE, and conduct a brief literature review of previous reports.
引用
收藏
页码:528 / 533
页数:6
相关论文
共 50 条
  • [1] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR HEMOGLOBIN A1C
    DAVIS, JE
    MCDONALD, JM
    JARETT, L
    DIABETES, 1978, 27 (02) : 102 - 107
  • [2] Effect of hemoglobin F and A2 on hemoglobin A1c determined by cation exchange high-performance liquid chromatography
    Can, Murat
    Guven, Berrak
    Akca, Ayse Semra Demir
    JOURNAL OF LABORATORY MEDICINE, 2019, 43 (05) : 265 - 268
  • [3] Interference of Thalassemias on Hemoglobin A1c Measurement by Ion-Exchange High-Performance Liquid Chromatography Method Tosoh HLC-723 G8
    Chao, Yan
    Wan, Zemin
    Wu, Xiaobin
    Qiu, Feng
    Wang, Yunxiu
    Ke, Peifeng
    Wu, Xinzhong
    Xu, Jianhua
    Zhuang, Junhua
    Huang, Xianzhang
    CLINICAL LABORATORY, 2018, 64 (7-8) : 1171 - 1175
  • [4] Evaluation of a fully automated high-performance liquid chromatography assay for hemoglobin A1c
    Khuu, HM
    Robinson, CA
    Goolsby, K
    Hardy, RW
    Konrad, RJ
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1999, 123 (09) : 763 - 767
  • [5] Common Hemoglobin Variants in Southern Taiwan and Their Effect on the Determination of HbA1c by Ion-exchange High-performance Liquid Chromatography
    Chu, Chih-Hsun
    Lam, Hing-Chung
    Lee, Jenn-Kuen
    Wang, Mei-Chun
    Lu, Chih-Chen
    Sun, Chun-Chin
    Chuang, Ming-Ju
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2009, 72 (07) : 362 - 367
  • [6] Evaluation of hemoglobin A1c measurement from filter paper using high-performance liquid chromatography and immunoturbidimetric assay
    Wu, Yonghua
    Yang, Xu
    Wang, Haining
    Li, Zhenrong
    Wang, Tiancheng
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2017, 77 (02): : 104 - 108
  • [7] HIGH-PERFORMANCE LIQUID ION-EXCHANGE CHROMATOGRAPHY
    SCHMUCKLER, G
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (8-9): : 1887 - 1901
  • [8] Hemoglobin Raleigh as the cause of a falsely increased hemoglobin A1C in an automated ion-exchange HPLC method
    Chen, D
    Crimmins, DL
    Hsu, FF
    Lindberg, FP
    Scott, MG
    CLINICAL CHEMISTRY, 1998, 44 (06) : 1296 - 1301
  • [9] Comparison of hemoglobin A1c and total glycated hemoglobin using high performance liquid chromatography (BioRad variant).
    Duffy, CA
    Duncan, MR
    Schellhorn, S
    Downing, RM
    Plapp, FV
    Miles, J
    CLINICAL CHEMISTRY, 1997, 43 : 218 - 218
  • [10] Standardization of method for determining glycosylated hemoglobin (Hb A1c) by cation exchange high performance liquid chromatography
    Antunes, Marina Venzon
    Wagner, Sandrine Comparsi
    Camargo, Joiza Lins
    Linden, Rafael
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2009, 45 (04) : 651 - 657