Uncommon causes of hemoglobin E flags identified during measurement of hemoglobin A1c by ion-exchange high-performance liquid chromatography

被引:0
|
作者
Herb, Thomas [1 ]
Taylor, Alexander S. [1 ]
Li, Shih-Hon [1 ]
Manthei, David M. [1 ]
Gherasim, Carmen [1 ]
机构
[1] Univ Michigan, Dept Pathol, Ann Arbor, MI 48109 USA
关键词
hemoglobin Hoshida; hemoglobin E; hemoglobin A1c; interference; hemoglobin variant; HPLC; clinical chemistry; VARIANTS; MANAGEMENT; VALUES; ASSAYS;
D O I
10.1093/labmed/lmad113
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We present 3 cases of discordant results from screening hemoglobin A1c (HbA1c) measured by ion-exchange high-performance liquid chromatography (HPLC) all due to various forms of interference and flagged by the instrument as "suspected hemoglobin E (HbE)." The first case was due to a rare hemoglobin variant, later confirmed to be hemoglobin Hoshida, the second due to "true" heterozygous HbE, and the third a result of analytical artifact causing splitting of the HbA1c peak without an underlying variant hemoglobin. We examine the similarities in these cases along with the laboratory work-up to classify each cause of interference to demonstrate the wide array of potential causes for the suspected HbE flag and why it warrants proper work-up. Because there is no standardized method of reporting out hemoglobin variant interference in HbA1c measurement, we discuss our laboratory's process of investigating discordant HbA1c measurements and reporting results in cases with variant interference as 1 possible model to follow, along with discussing the associated laboratory, ethical, and clinical considerations. We also examine the structure of hemoglobin Hoshida, HbE, and conduct a brief literature review of previous reports.
引用
收藏
页码:528 / 533
页数:6
相关论文
共 50 条
  • [21] ACCURACY, PRECISION, AND STABILITY IN MEASUREMENT OF HEMOGLOBIN-A1C BY HIGH-PERFORMANCE CATION-EXCHANGE CHROMATOGRAPHY
    SCHIFREEN, RS
    HICKINGBOTHAM, JM
    BOWERS, GN
    CLINICAL CHEMISTRY, 1980, 26 (03) : 466 - 472
  • [22] COMPARISON OF THREE HEMOGLOBIN A1C POINT OF CARE ANALYSERS WITH A HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) REFERENCE METHODS
    Fatas, M.
    Gasalla, J. M.
    Garcia, B.
    Janez, R.
    Hernando, C.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S678 - S678
  • [23] Performance of the TOSOH A1c 2.2 plus ion exchange HPLC analyzer for measurement of hemoglobin A1c in diabetic patients.
    Faix, JD
    CLINICAL CHEMISTRY, 1998, 44 : A165 - A165
  • [24] Effect of hemoglobin variants (Hb J, Hb G, and Hb E) on hemoglobin A1c measured by cation exchange high performance liquid chromatograph.
    Tsai, L
    CLINICAL CHEMISTRY, 2000, 46 (06) : A33 - A33
  • [25] A CATION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR HEMOGLOBIN-A1C AND HEMOGLOBIN SCREENING
    OU, CN
    CARMONA, P
    CLINICAL CHEMISTRY, 1985, 31 (06) : 945 - 945
  • [26] A pitfall in hemoglobin A1c measurement with high performance liquid chromatography method in the diagnosis of onset of fulminant type 1 diabetes mellitus
    Oe, Yasuharu
    Anno, Takatoshi
    Katsuhara, Yukari
    Sugahara, Ryo
    Kobayashi, Miki
    Yakusue, Mieko
    Tamura, Masayo
    Kimura, Yukiko
    Kawasaki, Fumiko
    Kaku, Kohei
    Kaneto, Hideaki
    Kitanaka, Akira
    JOURNAL OF DIABETES INVESTIGATION, 2022, 13 (11) : 1943 - 1944
  • [27] HEMOGLOBIN-A2 MEASUREMENT USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DEACONSMITH, R
    LORD, I
    MEDICAL LABORATORY SCIENCES, 1992, 49 (02): : 138 - 140
  • [28] Peculiarities of gradient ion-exchange high-performance liquid chromatography of proteins
    Dubinina, NI
    Kurenbin, OI
    Tennikova, TB
    JOURNAL OF CHROMATOGRAPHY A, 1996, 753 (02) : 217 - 225
  • [29] ION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY IN THE BREWING INDUSTRY
    KLEIN, H
    LEUBOLT, R
    JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2): : 259 - 270
  • [30] PURIFICATION OF ANTIBODIES VIA HIGH-PERFORMANCE LIQUID ION-EXCHANGE CHROMATOGRAPHY
    STOYANOV, AV
    ZHURNAL FIZICHESKOI KHIMII, 1994, 68 (10): : 1893 - 1896