Biomechanical comparison of headless compression screws versus independent locking screw for intra-articular fractures

被引:0
|
作者
Mandala, Meghana [1 ]
Shaunak, Shalin [2 ]
Kreitmair, Paul [3 ]
Phadnis, Joideep [2 ]
Guryel, Enis [2 ]
机构
[1] Brighton & Sussex Med Sch, Brighton, England
[2] Univ Hosp Sussex NHS Fdn Trust, Brighton, England
[3] Univ Sussex, Brighton, England
关键词
Intra-articular fractures; Headless compression screws; Locking screws; Acutrak; Synthes; Smith and Nephew; Compression force; INTERFRAGMENTARY COMPRESSION; HERBERT SCREW; LAG SCREW; FIXATION;
D O I
10.1007/s00590-023-03792-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Headless compression screws (HCS) have a variable thread pitch and headless design enabling them to embed below the articular surface and generate compression force for fracture healing without restricting movement. Locking screws have greater variety of dimensions and a threaded pitch mirroring the design of the HCS. The objective of this study is to determine whether locking screws can generate compression force and compare the compressive forces generated by HCS versus locking screws.Method A comparison between 3.5-mm HCS versus 3.5-mm locking screws and 2.8-mm HCS versus 2.7-mm locking screws was performed using a synthetic foam bone model (Synbone) and FlexiForce sensors to record the compression forces (N). The mean peak compression force was calculated from a sample of 3 screws for each screw type. Statistical analysis was performed using the one-way ANOVA test and statistical significance was determined to be p = < 0.05.Results The 3.5-mm Synthes and Smith and Nephew locking screws generated similar peak compression forces to the 3.5-mm Acutrak 2 headless compression screws with no statistically significant difference between them. The smaller 2.7-mm Synthes and Smith and Nephew locking screws initially generated similar compressive forces up to 1.5 and 2 revolutions, respectively, but their peak compression force was less compared to the 2.8-mm Micro Acutrak 2 HCS.Conclusion Locking screws are able to generate compressive forces and may be a viable alternative to headless compressive screws supporting their use for intra-articular fractures.
引用
收藏
页码:1319 / 1325
页数:7
相关论文
共 50 条
  • [41] Percutaneous Reduction and Screw Fixation of Displaced Intra-articular Fractures of the Calcaneus
    Tantavisut, Saran
    Phisitkul, Phinit
    Westerlind, Brian O.
    Gao, Yubo
    Karam, Matthew D.
    Marsh, John L.
    FOOT & ANKLE INTERNATIONAL, 2017, 38 (04) : 367 - 374
  • [42] CLINICAL OUTCOME OF INTRA-ARTICULAR DISTAL RADIUS FRACTURES TREATED WITH PLATE AND SCREWS
    Girish, K. R.
    Hosangadi, A. A.
    Korlhalli, Suresh
    Suryakanth, K.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (18): : 3110 - 3123
  • [43] Comparison of Percutaneous Screw Fixation and Calcium Sulfate Cement Grafting Versus Open Treatment of Displaced Intra-Articular Calcaneal Fractures
    Chen, Linwei
    Zhang, Guoyou
    Hong, Jianjun
    Lu, Xiaolang
    Yuan, Wen
    FOOT & ANKLE INTERNATIONAL, 2011, 32 (10) : 979 - 985
  • [44] Shear fractures of the distal humerus: Is the use of intra-articular screws a safe treatment?
    Tarallo L.
    Mugnai R.
    Adani R.
    Zambianchi F.
    Costanzini C.A.
    Catani F.
    MUSCULOSKELETAL SURGERY, 2015, 99 (3) : 217 - 223
  • [45] Biomechanical Comparison of a Locking Plate with Intraplate Compression Screw Versus Locking Plate with Plantar Interfragmentary Screw for Lapidus Arthrodesis: A Cadaveric Study
    Cottom, James M.
    Rigby, Ryan B.
    JOURNAL OF FOOT & ANKLE SURGERY, 2013, 52 (03): : 339 - 342
  • [46] Computed Tomography Evaluation of Distal Screw Penetration in Volar Locking Plate Fixation for Intra-Articular Distal Radius Fractures
    Kaneshiro, Yasunori
    Hyun, Seungho
    Yano, Koichi
    Yokoi, Takuya
    Sakanaka, Hideki
    Hidaka, Noriaki
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (06): : 553 - 558
  • [47] Biomechanical Comparison of Tension Band Fixation of Patella Transverse Fracture: Headless Screws Versus Headed Screws
    Martin, Jill M.
    Applin, Dylan T.
    McGrady, Linda M.
    Wang, Mei
    Schmeling, Gregory J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (06) : E240 - E245
  • [48] Biomechanical Comparison of Hook Plate vs Headless Compression Screw Fixation of Large Fifth Metatarsal Base Avulsion Fractures
    Bean, Bryan A.
    Smyth, Niall A.
    Abbasi, Pooyan
    Parks, Brent G.
    Hembree, Walter C.
    FOOT & ANKLE INTERNATIONAL, 2021, 42 (01) : 89 - 95
  • [49] Biomechanical comparison of headless antegrade screw versus retrograde cortical screw for coronoid fracture fixation
    Hapa, Onur
    Karakasli, Ahmet
    Dincer, Cemal
    Zhamilov, Vadym
    Guvencer, Mustafa
    Havitcioglu, Hasan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2015, 49 (03) : 307 - 310
  • [50] Mechanical Comparison of Headless Screw Fixation and Locking Plate Fixation for Talar Neck Fractures
    Karakasli, Ahmet
    Hapa, Onur
    Erduran, Mehmet
    Dincer, Cemal
    Cecen, Berivan
    Havitcioglu, Hasan
    JOURNAL OF FOOT & ANKLE SURGERY, 2015, 54 (05): : 905 - 909