Biomechanical comparison of headless compression screws versus independent locking screw for intra-articular fractures

被引:0
|
作者
Mandala, Meghana [1 ]
Shaunak, Shalin [2 ]
Kreitmair, Paul [3 ]
Phadnis, Joideep [2 ]
Guryel, Enis [2 ]
机构
[1] Brighton & Sussex Med Sch, Brighton, England
[2] Univ Hosp Sussex NHS Fdn Trust, Brighton, England
[3] Univ Sussex, Brighton, England
关键词
Intra-articular fractures; Headless compression screws; Locking screws; Acutrak; Synthes; Smith and Nephew; Compression force; INTERFRAGMENTARY COMPRESSION; HERBERT SCREW; LAG SCREW; FIXATION;
D O I
10.1007/s00590-023-03792-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Headless compression screws (HCS) have a variable thread pitch and headless design enabling them to embed below the articular surface and generate compression force for fracture healing without restricting movement. Locking screws have greater variety of dimensions and a threaded pitch mirroring the design of the HCS. The objective of this study is to determine whether locking screws can generate compression force and compare the compressive forces generated by HCS versus locking screws.Method A comparison between 3.5-mm HCS versus 3.5-mm locking screws and 2.8-mm HCS versus 2.7-mm locking screws was performed using a synthetic foam bone model (Synbone) and FlexiForce sensors to record the compression forces (N). The mean peak compression force was calculated from a sample of 3 screws for each screw type. Statistical analysis was performed using the one-way ANOVA test and statistical significance was determined to be p = < 0.05.Results The 3.5-mm Synthes and Smith and Nephew locking screws generated similar peak compression forces to the 3.5-mm Acutrak 2 headless compression screws with no statistically significant difference between them. The smaller 2.7-mm Synthes and Smith and Nephew locking screws initially generated similar compressive forces up to 1.5 and 2 revolutions, respectively, but their peak compression force was less compared to the 2.8-mm Micro Acutrak 2 HCS.Conclusion Locking screws are able to generate compressive forces and may be a viable alternative to headless compressive screws supporting their use for intra-articular fractures.
引用
收藏
页码:1319 / 1325
页数:7
相关论文
共 50 条
  • [31] A biomechanical comparison of the Delta screw and RetroScrew tibial fixation on initial intra-articular graft tension
    Rhee, Peter C.
    Levy, Bruce A.
    Stuart, Michael J.
    Thoreson, Andrew
    An, Kai-Nan
    Dahm, Diane L.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (05) : 781 - 786
  • [32] Screw fixation of radial head fractures: Compression screw versus lag screw-A biomechanical comparison
    Burkhart, Klaus J.
    Nowak, Tobias E.
    Appelmann, Philipp
    Sternstein, Werner
    Rommens, Pol M.
    Mueller, Lars P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (10): : 1015 - 1019
  • [33] Biomechanical comparison of plate, intramedullary screw, and headless compression screw fixation in Danis–Weber type B lateral malleolar fractures
    Chen-Yuan Yang
    Wei-Chun Hong
    Ming-Tzu Tsai
    Jui-Ting Hsu
    Journal of Orthopaedic Surgery and Research, 20 (1)
  • [34] Biomechanical Comparison of Parallel Versus 90-90 Plating of Bicolumn Distal Humerus Fractures With Intra-Articular Comminution
    Got, Christopher
    Shuck, John
    Biercevicz, Alison
    Paller, Dave
    Mulcahey, Mary
    Zimmermann, Matthew
    Blaine, Theodore
    Green, Andrew
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (12): : 2512 - 2518
  • [35] Treatment of Capitellum and Trochlea Fractures Using Headless Compression Screws and a Combination of Dorsolateral Locking Plates
    Yoshida, Shiro
    Sakai, Kensuke
    Nakama, Kenjiro
    Matsuura, Mitsuhiro
    Okazaki, Shingo
    Jimbo, Kotaro
    Shirahama, Masahiro
    Shiba, Naoto
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (03)
  • [36] Biomechanical evaluation of parallel versus orthogonal plate fixation of intra-articular distal humerus fractures
    Zalavras, Charalampos G.
    Vercillo, Michael T.
    Jun, Bong-Jae
    Otarodifard, Karimdad
    Itamura, John M.
    Lee, Thay Q.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (01) : 12 - 20
  • [37] Fixation of intra-articular calcaneal fractures: A comparative study of the postoperative outcome between HA/PPLA screws and locking plates
    Usami, Takuya
    Takada, Naoya
    Nishida, Kazuki
    Sakai, Hiroaki
    Iwata, Hidetoshi
    Yonezu, Hiroki
    Sekiya, Isato
    Nagaya, Yuko
    Ueki, Yoshino
    Murakami, Hideki
    Kuroyanagi, Gen
    HELIYON, 2023, 9 (03)
  • [38] OPERATIVE MANAGEMENT OF INTRA-ARTICULAR DISTAL HUMERAL FRACTURES WITH LOCKING PLATES
    Mishra, Abhilekh
    Singh, Vidya Bhushan
    Chaurasia, Amit
    Lakhtakia, P. K.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (94): : 15923 - 15926
  • [39] Biomechanical comparison of three different compression screws for treatment of odontoid fractures evaluation of a new screw design
    Mueller, Jan-Uwe
    Mueller, Jonas
    Marx, Sascha
    Matthes, Marc
    Nowak, Stephan
    Schroeder, Henry Werner Siegfried
    Pillich, Dirk Thomas
    CLINICAL BIOMECHANICS, 2020, 77
  • [40] INTRA-ARTICULAR TALAR FRACTURES - REPAIR USING THE HERBERT BONE SCREW
    MALLON, WJ
    WOMBWELL, JH
    NUNLEY, JA
    FOOT & ANKLE, 1989, 10 (02): : 88 - 92