Real-time monitoring of ultra-high dose rate electron beams using bremsstrahlung photons

被引:0
|
作者
Kim, Hyun [1 ]
Jeong, Dong Hyeok [1 ]
Kang, Sang Koo [1 ]
Lee, Manwoo [1 ]
Lim, Heuijin [1 ]
Lee, Sang Jin [1 ]
Jang, Kyoung Won [1 ]
机构
[1] Dongnam Inst Radiol & Med Sci, Res Ctr, Busan 46033, South Korea
关键词
UHDR electron Beams; Real-time monitoring; Ionization chamber; FLASH radiotherapy; RECOMBINATION; IRRADIATION; COLLECTION; DOSIMETRY;
D O I
10.1016/j.net.2023.05.033
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Recently, as the clinically positive biological effects of ultra-high dose rate (UHDR) radiation beams have been revealed, interest in flash radiation therapy has increased. Generally, FLASH preclinical experiments are performed using UHDR electron beams generated by linear accelerators. Real-time monitoring of UHDR beams is required to deliver the correct dose to a sample. However, it is difficult to use typical transmission-type ionization chambers for primary beam monitoring because there is no suitable electrometer capable of reading high pulsed currents, and collection efficiency is drastically reduced in pulsed radiation beams with ultra-high doses. In this study, a monitoring method using bremsstrahlung photons generated by irradiation devices and a water phantom was proposed. Charges collected in an ionization chamber located at the back of a water phantom were analyzed using the bremsstrahlung tail on electron depth dose curves obtained using radiochromic films. The dose conversion factor for converting a monitored charge into a delivered dose was determined analytically for the Advanced Markus & REG; chamber and compared with experimentally determined values. It is anticipated that the method proposed in this study can be useful for monitoring sample doses in UHDR electron beam irradiation. & COPY; 2023 Korean Nuclear Society, Published by Elsevier Korea LLC. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:3417 / 3422
页数:6
相关论文
共 50 条
  • [1] Calorimeter for Real-Time Dosimetry of Pulsed Ultra-High Dose Rate Electron Beams
    Bourgouin, Alexandra
    Schueller, Andreas
    Hackel, Thomas
    Kranzer, Rafael
    Poppinga, Daniela
    Kapsch, Ralf-Peter
    McEwen, Malcolm
    FRONTIERS IN PHYSICS, 2020, 8
  • [2] Verification of real-time dosimetry of ultra-high dose rate beams at AQURE FLASH RT on the sample surface
    Lenartowicz-Gasik, Aleksandra
    Misiarz, Agnieszka
    Markopolski, Vasyl
    Walo, Marta
    Gryczka, Urszula
    Bulka, Sylwester
    Pawalowski, Bartosz
    Kruszyna-Mochalska, Marta
    Rzadkiewicz, Jacek
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2024, 30 (04):
  • [3] A prototype scintillator real-time beam monitor for ultra-high dose rate radiotherapy
    Levin, Daniel S.
    Friedman, Peter S.
    Ferretti, Claudio
    Ristow, Nicholas
    Tecchio, Monica
    Litzenberg, Dale W.
    Bashkirov, Vladimir
    Schulte, Reinhard
    MEDICAL PHYSICS, 2024, 51 (04) : 2905 - 2923
  • [4] Real-time measurement and monitoring of absorbed dose for electron beams
    Korenev, S
    Korenev, I
    Rumega, S
    Grossman, L
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (1-2) : 317 - 322
  • [5] Silicon carbide detectors for dosimetry and monitoring of ultra-high dose rate beams
    Okpuwe, C.
    Amato, A.
    D'Amico, I.
    De Liso, V.
    De Napoli, M.
    Di Martino, F.
    Felici, G.
    Galluzzo, L.
    Medina, E.
    Vignati, A.
    Camarda, M.
    Romano, F.
    Milluzzo, G.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (03)
  • [6] Investigation of TL and OSL detectors in ultra-high dose rate electron beams
    Motta, S.
    Christensen, J. B.
    Frei, F.
    Peier, P.
    Yukihara, E. G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (14):
  • [7] First experimental validation of silicon-based sensors for monitoring ultra-high dose rate electron beams
    Medina, Elisabetta
    Ferro, Arianna
    Abujami, Mohammad
    Camperi, Aurora
    Centis Vignali, Matteo
    Data, Emanuele
    Del Sarto, Damiano
    Deut, Umberto
    Di Martino, Fabio
    Fadavi Mazinani, Mohammad
    Ferrero, Marco
    Ferrero, Veronica
    Giordanengo, Simona
    Marti Villarreal, Oscar A.
    Hosseini, Mohammad Amin
    Mas Milian, Felix
    Masturzo, Luigi
    Montalvan Olivares, Diango M.
    Montefiori, Marco
    Paternoster, Giovanni
    Pensavalle, Jake Harold
    Sola, Valentina
    Cirio, Roberto
    Sacchi, Roberto
    Vignati, Anna
    FRONTIERS IN PHYSICS, 2024, 12
  • [8] Dosimetry of ultra-high dose rate electron beams using thermoluminescence and optically stimulated luminescence detectors
    Motta, S.
    Dal Bello, R.
    Christensen, J. B.
    Bossin, L.
    Yukihara, E. G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (03):
  • [9] Absolute Dosimetry of Ultra-High Dose Rate Pulsed Electron Beams Using a Graphite Probe Calorimeter
    Keszti, F.
    Bourgouin, A.
    Schueller, A.
    Simon, W.
    Schoenfeld, A.
    Seuntjens, J.
    Renaud, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [10] Dose and dose rate dependence of the tissue sparing effect at ultra-high dose rate studied for proton and electron beams using the zebrafish embryo model
    Horst, Felix
    Bodenstein, Elisabeth
    Brand, Michael
    Hans, Stefan
    Karsch, Leonhard
    Lessmann, Elisabeth
    Loeck, Steffen
    Schuerer, Michael
    Pawelke, Joerg
    Beyreuther, Elke
    RADIOTHERAPY AND ONCOLOGY, 2024, 194