Recently, as the clinically positive biological effects of ultra-high dose rate (UHDR) radiation beams have been revealed, interest in flash radiation therapy has increased. Generally, FLASH preclinical experiments are performed using UHDR electron beams generated by linear accelerators. Real-time monitoring of UHDR beams is required to deliver the correct dose to a sample. However, it is difficult to use typical transmission-type ionization chambers for primary beam monitoring because there is no suitable electrometer capable of reading high pulsed currents, and collection efficiency is drastically reduced in pulsed radiation beams with ultra-high doses. In this study, a monitoring method using bremsstrahlung photons generated by irradiation devices and a water phantom was proposed. Charges collected in an ionization chamber located at the back of a water phantom were analyzed using the bremsstrahlung tail on electron depth dose curves obtained using radiochromic films. The dose conversion factor for converting a monitored charge into a delivered dose was determined analytically for the Advanced Markus & REG; chamber and compared with experimentally determined values. It is anticipated that the method proposed in this study can be useful for monitoring sample doses in UHDR electron beam irradiation. & COPY; 2023 Korean Nuclear Society, Published by Elsevier Korea LLC. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:3417 / 3422
页数:6
相关论文
共 50 条
  • [31] Characterization of Ultra-High-Dose Rate Electron Beams with ElectronFlash Linac
    Giuliano, Lucia
    Franciosini, Gaia
    Palumbo, Luigi
    Aggar, Lilia
    Dutreix, Marie
    Faillace, Luigi
    Favaudon, Vincent
    Felici, Giuseppe
    Galante, Federica
    Mostacci, Andrea
    Migliorati, Mauro
    Pacitti, Matteo
    Patriarca, Annalisa
    Heinrich, Sophie
    APPLIED SCIENCES-BASEL, 2023, 13 (01):
  • [32] Metrology for advanced radiotherapy using particle beams with ultra-high dose rates
    Subiel, Anna
    Bourgouin, Alexandra
    Kranzer, Rafael
    Peier, Peter
    Frei, Franziska
    Gomez, Faustino
    Knyziak, Adrian
    Fleta, Celeste
    Bailat, Claude
    Schueller, Andreas
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (14):
  • [33] Time-Resolved Ultra-High Resolution Optical Coherence Tomography for Real-Time Monitoring of Selective Retina Therapy
    Steiner, Patrick
    Ebneter, Andreas
    Berger, Lieselotte Erika
    Zinkernagel, Martin
    Povazay, Boris
    Meier, Christoph
    Kowal, Jens H.
    Framme, Carsten
    Brinkmann, Ralf
    Wolf, Sebastian
    Sznitman, Raphael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (11) : 6654 - 6662
  • [34] A Novel Collimator for High-Throughput Murine Hemi- and Whole-Thoracic Lung Irradiation Using Ultra-High Dose Rate Electron Beams
    Huang, K.
    Byrne, K. E.
    Bazyar, S.
    Tran, P.
    Sawant, A.
    Jiang, K.
    MEDICAL PHYSICS, 2024, 51 (10) : 7771 - 7771
  • [35] Absorbed-dose-to-water measurement using alanine in ultra-high-pulse-dose-rate electron beams
    Bourgouin, Alexandra
    Hackel, Thomas
    Marinelli, Marco
    Kranzer, Rafael
    Schueller, Andreas
    Kapsch, Ralf-Peter
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (20):
  • [36] Diamond detectors for dose and instantaneous dose-rate measurements for ultra-high dose-rate scanned helium ion beams
    Tessonnier, Thomas
    Verona-Rinati, Gianluca
    Rank, Luisa
    Kranzer, Rafael
    Mairani, Andrea
    Marinelli, Marco
    MEDICAL PHYSICS, 2024, 51 (02) : 1450 - 1459
  • [37] Implementation and validation of beam current transformer for Mobetron ultra-high dose rate electron beam monitoring using multi-detector approach
    Famulari, Gabriel
    Zerouali, Karim
    Renaud, James
    Muir, Bryan
    Aubry, Jean-Francois
    DeBlois, Francois
    Carrier, Jean-Francois
    MEDICAL PHYSICS, 2022, 49 (08) : 5707 - 5707
  • [38] Real-time corrosion monitoring of an ultra-high performance fibre-reinforced concrete offshore raft by using an autonomous sensor system
    Ramon, Jose E.
    Gandia-Romero, Jose M.
    Bataller, Roman
    Lopez, Juan A.
    Valcuende, Manuel
    Soto, Juan
    STRUCTURAL CONTROL & HEALTH MONITORING, 2022, 29 (11):
  • [39] Modification of Commercial Radiotherapy System for Ultra-High Dose Rate Electron Beam Irradiation
    Kim, E.
    Yang, K.
    Kim, M. S.
    Jang, W. I.
    Lee, D. H.
    Kim, K. T.
    Cho, G. S.
    Kim, J. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E566 - E566
  • [40] Modeling ultra-high dose rate electron and proton FLASH effect with the physicochemical approach
    Tan, Hai Siong
    Teo, Kevin Boon Keng
    Dong, Lei
    Friberg, Andrew
    Koumenis, Constantinos
    Diffenderfer, Eric
    Zou, Jennifer Wei
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (14):