Compact Micro-Coriolis Mass-Flow Meter with Optical Readout

被引:0
|
作者
Yariesbouei, Mahdieh [1 ]
Sanders, Remco G. P. [1 ]
Wiegerink, Remco J. [1 ]
Lotters, Joost C. [1 ,2 ]
机构
[1] Univ Twente, Integrated Devices & Syst, NL-7522 NB Enschede, Netherlands
[2] Bronkhorst High Tech BV, NL-7261 AK Ruurlo, Netherlands
关键词
compact micro-Coriolis mass-flow meter; nickel electroplated tube; optical readout; SENSOR STRUCTURE; DENSITY;
D O I
10.3390/mi15010114
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents the first nickel-plated micro-Coriolis mass-flow sensor with integrated optical readout. The sensor consists of a freely suspended tube made of electroplated nickel with a total length of 60 mm, an inner diameter of 580 mu m, and a wall thickness of approximately 8 mu m. The U-shaped tube is actuated by Lorentz forces. An optical readout consisting of two LEDs and two phototransistors is used to detect the tube motion. Mass-flow measurements were performed at room temperature with water and isopropyl alcohol for flows up to 200 g/h and 100 g/h, respectively. The measured resonance frequencies were 1.67 kHz and 738 Hz for water and 1.70 kHz and 752 Hz for isopropyl alcohol for the twist and swing modes, respectively. The measured phase shift between the two readout signals shows a linear response to mass flow with very similar sensitivities for water and isopropyl alcohol of 0.41mdegg/h and 0.43 mdegg/h, respectively.
引用
收藏
页数:12
相关论文
共 50 条
  • [11] Vibration Isolation by an Actively Compliantly Mounted Sensor Applied to a Coriolis Mass-Flow Meter
    van de Ridder, L.
    Hakvoort, Wouter B. J.
    van Dijk, Johannes
    Lotters, Joost C.
    de Boer, Andre
    [J]. JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2016, 138 (03):
  • [12] Coriolis mass-flow meter with integrated multi-DOF active vibration isolation
    van de Ridder, L.
    Hakvoort, W. B. J.
    Brouwer, D. M.
    van Dijk, J.
    Lotters, J. C.
    de Boer, A.
    [J]. MECHATRONICS, 2016, 36 : 167 - 179
  • [13] CORIOLIS-EFFECT IN MASS-FLOW METERING
    RASZILLIER, H
    DURST, F
    [J]. ARCHIVE OF APPLIED MECHANICS, 1991, 61 (03) : 192 - 214
  • [14] MASS-FLOW MEASUREMENT AIDED BY CORIOLIS METHODS
    BLICKLEY, GJ
    [J]. CONTROL ENGINEERING, 1991, 38 (06) : 53 - 56
  • [15] MEASURING MASS-FLOW AND DENSITY WITH CORIOLIS METERS
    HALL, R
    [J]. INTECH, 1990, 37 (04) : 45 - 46
  • [16] MICRO CORIOLIS MASS FLOW SENSOR WITH PIEZOELECTRIC TRANSDUCERS FOR BOTH ACTUATION AND READOUT
    Zeng, Yaxiang
    Wiegerink, Remco J.
    Lotters, Joost C.
    [J]. 2022 IEEE 35TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS CONFERENCE (MEMS), 2022, : 59 - 62
  • [17] CORIOLIS-FORCE MASS-FLOW METER COMPOSED OF A STRAIGHT PIPE AND AN ADDITIONAL RESONANCE-VIBRATOR
    TSUTSUI, H
    TOMIKAWA, Y
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (5B): : 2369 - 2371
  • [18] MASS-FLOW MEASUREMENT USING CORIOLIS-PRINCIPLE
    NORDENSSON, C
    [J]. KEMISK TIDSKRIFT, 1990, 102 (08): : 45 - 45
  • [19] μ-Coriolis Mass Flow Sensor with Resistive Readout
    Schut, Thomas
    Wiegerink, Remco
    Lotters, Joost
    [J]. MICROMACHINES, 2020, 11 (02)
  • [20] FLOW IN A ROTATING STRAIGHT PIPE, WITH A VIEW ON CORIOLIS MASS-FLOW METERS
    DURST, F
    RASZILLIER, H
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (02): : 149 - 154