This paper deals with a new construction for a mass-flow meter using Coriolis force, and its basic experimental results. Some Coriolis force mass-flow meters', proposed up to now, are of a twin construction of, for example, a U-type pipe or a straight-type pipe, where the mass-flow is determined by measuring the relative displacement between the pipes. Therefore, their structure is too complex. To improve this situation, the authors propose a new mass-flow meter using one straight pipe, together with an additional flexural resonance-vibrator. The experimental results prove that a mass-flow meter can be realized by such a simple construction as dealt with here.
引用
收藏
页码:2369 / 2371
页数:3
相关论文
共 9 条
  • [1] FLOW IN A ROTATING STRAIGHT PIPE, WITH A VIEW ON CORIOLIS MASS-FLOW METERS
    DURST, F
    RASZILLIER, H
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (02): : 149 - 154
  • [2] Compact Micro-Coriolis Mass-Flow Meter with Optical Readout
    Yariesbouei, Mahdieh
    Sanders, Remco G. P.
    Wiegerink, Remco J.
    Lotters, Joost C.
    [J]. MICROMACHINES, 2024, 15 (01)
  • [3] A self-validating digital Coriolis mass-flow meter: an overview
    Henry, MP
    Clarke, DW
    Archer, N
    Bowles, J
    Leahy, MJ
    Liu, RP
    Vignos, J
    Zhou, FB
    [J]. CONTROL ENGINEERING PRACTICE, 2000, 8 (05) : 487 - 506
  • [4] Non-linear Control of the Oscillation Amplitude of a Coriolis Mass-Flow Meter
    Clarke, D. W.
    [J]. EUROPEAN JOURNAL OF CONTROL, 1998, 4 (03) : 196 - 207
  • [5] Quantification of the influence of external vibrations on the measurement error of a Coriolis mass-flow meter
    van de Ridder, L.
    Hakvoort, W. B. J.
    van Dijk, J.
    Lotters, J. C.
    de Boer, A.
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2014, 40 : 39 - 49
  • [6] VIBRATION ISOLATION BY COMPLIANT SENSOR MOUNTING APPLIED TO A CORIOLIS MASS-FLOW METER
    van de Ridder, L.
    Hakvoort, Wouter B. J.
    van Dijk, Johannes
    [J]. PROCEEDINGS OF THE ASME 12TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS - 2014, VOL 2, 2014,
  • [7] Coriolis mass-flow meter with integrated multi-DOF active vibration isolation
    van de Ridder, L.
    Hakvoort, W. B. J.
    Brouwer, D. M.
    van Dijk, J.
    Lotters, J. C.
    de Boer, A.
    [J]. MECHATRONICS, 2016, 36 : 167 - 179
  • [8] Vibration Isolation by an Actively Compliantly Mounted Sensor Applied to a Coriolis Mass-Flow Meter
    van de Ridder, L.
    Hakvoort, Wouter B. J.
    van Dijk, Johannes
    Lotters, Joost C.
    de Boer, Andre
    [J]. JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2016, 138 (03):
  • [9] Modeling of Coriolis mass flow meter of a general plane-shape pipe
    Guirguis, Samer
    Fan ShangChun
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2010, 21 (01) : 40 - 47