FLOW IN A ROTATING STRAIGHT PIPE, WITH A VIEW ON CORIOLIS MASS-FLOW METERS

被引:3
|
作者
DURST, F
RASZILLIER, H
机构
[1] Universität Erlangen-Niürnberg, Erlangen
关键词
D O I
10.1115/1.2909378
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The fully developed flow through a straight pipe, which rotates about an axis perpendicular to its own, is considered. The perturbation of the Hagen-Poiseuille flow, produced by the pipe rotation, is computed to second order and its features are described. The force of the fluid on the rotating pipe is correlated with other parameters of the flow, among them the mass flow rate Q. Possible relevance of the flow field and of the fluid forces in the rotating pipe for Coriolis flow meters are discussed. © 1990 by ASME.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 50 条
  • [1] MEASURING MASS-FLOW AND DENSITY WITH CORIOLIS METERS
    HALL, R
    [J]. INTECH, 1990, 37 (04) : 45 - 46
  • [2] Active vibration isolation feedback control for Coriolis Mass-Flow Meters
    van de Ridder, L.
    Beijen, M. A.
    Hakvoort, W. B. J.
    van Dijk, J.
    Lotters, J. C.
    de Boer, A.
    [J]. CONTROL ENGINEERING PRACTICE, 2014, 33 : 76 - 83
  • [3] CORIOLIS-FORCE MASS-FLOW METER COMPOSED OF A STRAIGHT PIPE AND AN ADDITIONAL RESONANCE-VIBRATOR
    TSUTSUI, H
    TOMIKAWA, Y
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (5B): : 2369 - 2371
  • [4] CORIOLIS MASS-FLOW ON THE HIGH ROAD
    TINHAM, B
    [J]. CONTROL AND INSTRUMENTATION, 1993, 25 (02): : 29 - &
  • [5] The effect of flow pulsations on coriolis mass flow meters
    Cheesewright, R
    Clark, C
    [J]. JOURNAL OF FLUIDS AND STRUCTURES, 1998, 12 (08) : 1025 - 1039
  • [6] CORIOLIS-EFFECT IN MASS-FLOW METERING
    RASZILLIER, H
    DURST, F
    [J]. ARCHIVE OF APPLIED MECHANICS, 1991, 61 (03) : 192 - 214
  • [7] MASS-FLOW MEASUREMENT AIDED BY CORIOLIS METHODS
    BLICKLEY, GJ
    [J]. CONTROL ENGINEERING, 1991, 38 (06) : 53 - 56
  • [8] Gas mass-flow meters: Measurement and uncertainties
    Amador de Matos, Manuel Arlindo
    Fernandes Rodrigues, Nuno Jose
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2013, 33 : 45 - 54
  • [9] The dynamic response of Coriolis mass flow meters
    Cheesewright, R
    Clark, C
    Belhadj, A
    Hou, YY
    [J]. JOURNAL OF FLUIDS AND STRUCTURES, 2003, 18 (02) : 165 - 178
  • [10] MASS-FLOW MEASUREMENT BY MEANS OF FLOW MODULATION IN A PIPE
    GAST, T