Biomechanical Effect of Hybrid Dynamic Stabilization Implant on the Segmental Motion and Intradiscal Pressure in Human Lumbar Spine

被引:5
|
作者
Hsiao, Chih-Kun [1 ]
Tsai, Yi-Jung [1 ]
Yen, Cheng-Yo [2 ]
Li, Yi-Chen [2 ]
Hsiao, Hao-Yuan [2 ]
Tu, Yuan-Kun [2 ]
机构
[1] E Da Hosp, Dept Med Res, Kaohsiung 82445, Taiwan
[2] E Da Hosp, Dept Orthopaed, Kaohsiung 82445, Taiwan
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 01期
关键词
dynamic stabilization systems; Dynesys-Transition-Optima; range of motion; intradiscal pressure;
D O I
10.3390/bioengineering10010031
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The hybrid dynamic stabilization system, Dynesys-Transition-Optima, represents a novel pedicle-based construct for the treatment of lumbar degenerative disease. The theoretical advantage of this system is to stabilize the treated segment and preserve the range of motion within the adjacent segment while potentially decreasing the risk of adjacent segment disease following lumbar arthrodesis. Satisfactory short-term outcomes were previously demonstrated in the Dynesys-Transition-Optima system. However, long-term follow-up reported accelerated degeneration of adjacent segments and segmental instability above the fusion level. This study investigated the biomechanical effects of the Dynesys-Transition-Optima system on segment motion and intradiscal pressure at adjacent and implanted levels. Segmental range of motion and intradiscal pressure were evaluated under the conditions of the intact spine, with a static fixator at L4-5, and implanted with DTO at L3-4 (Dynesys fixator) and L4-5 (static fixator) by applying the loading conditions of flexion/extension (+/- 7.5 Nm) and lateral bending (+/- 7.5 Nm), with/without a follower preload of 500 N. Our results showed that the hybrid Dynesys-Transition-Optima system can significantly reduce the ROM at the fusion level (L4-L5), whereas the range of motion at the adjacent level (L3-4) significantly increased. The increase in physiological loading could be an important factor in the increment of IDP at the intervertebral discs at the lumbar spine. The Dynesys-Transition-Optima system can preserve the mobility of the stabilized segments with a lesser range of motion on the transition segment; it may help to prevent the occurrence of adjacent segment degeneration. However, the current study cannot cover all the issues of adjacent segmental diseases. Future investigations of large-scale and long-term follow-ups are needed.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] The Influence of Distraction Force on the Intradiscal Pressure Gradient in the Bridged Lumbar Spine A Biomechanical Investigation Using a Calf Model
    Spiegl, Ulrich
    Paetzold, Robert
    Glasmacher, Stefan
    Stephan, Daniel
    Josten, Christoph
    Buehren, Volker
    Gonschorek, Oliver
    Augat, Peter
    SPINE, 2014, 39 (07) : E427 - E433
  • [22] Spinal motion and intradiscal pressure measurements before and after lumbar spine instrumentation with titanium or PEEK rods
    Abode-Iyamah, Kingsley
    Kim, Sam Byeong
    Grosland, Nicole
    Kumar, Rajinder
    Belirgen, Muhittin
    Lim, Tae Hong
    Torner, James
    Hitchon, Patrick W.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2014, 21 (04) : 651 - 655
  • [23] Biomechanical study of lumbar spine with dynamic stabilization device using finite element method
    Shin, Dong Suk
    Lee, Kunwoo
    Kim, Daniel
    COMPUTER-AIDED DESIGN, 2007, 39 (07) : 559 - 567
  • [24] The effect of non -fusion dynamic stabilization on biomechanical responses of the implanted lumbar spine during whole -body vibration
    Fan, Wei
    Guo, Li-Xin
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 192
  • [25] Segmental in vivo vertebral motion during functional human lumbar spine activities
    Li, Guoan
    Wang, Shaobai
    Passias, Peter
    Xia, Qun
    Li, Gang
    Wood, Kirkham
    EUROPEAN SPINE JOURNAL, 2009, 18 (07) : 1013 - 1021
  • [26] Segmental in vivo vertebral motion during functional human lumbar spine activities
    Guoan Li
    Shaobai Wang
    Peter Passias
    Qun Xia
    Gang Li
    Kirkham Wood
    European Spine Journal, 2009, 18 : 1013 - 1021
  • [27] In Vitro Biomechanical Study to Quantify Range of Motion, Intradiscal Pressure, and Facet Force of 3-Level Dynamic Stabilization Constructs With Decreased Stiffness
    Lee, Joseph K.
    Gomez, Jaime
    Michelsen, Christopher
    Kim, Yongjung
    Moldavsky, Mark
    Chinthakunta, Suresh Reddy
    Khalil, Saif
    SPINE, 2013, 38 (22) : 1913 - 1919
  • [28] Finite element modelling of hybrid stabilization systems for the human lumbar spine
    Demir, Eylul
    Eltes, Peter
    Castro, Andre P. G.
    Lacroix, Damien
    Toktas, Ihsan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2020, 234 (12) : 1409 - 1420
  • [29] The use of a hybrid dynamic stabilization and fusion system in the lumbar spine: preliminary experience
    Maserati, Matthew B.
    Tormenti, Matthew J.
    Panczykowski, David M.
    Bonfield, Christopher M.
    Gerszten, Peter C.
    NEUROSURGICAL FOCUS, 2010, 28 (06) : 1 - 4
  • [30] Biomechanical comparison of effects of the Dynesys and Coflex dynamic stabilization systems on range of motion and loading characteristics in the lumbar spine: a finite element study
    Kulduk, Ahmet
    Altun, Necdet S.
    Senkoylu, Alpaslan
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2015, 11 (04): : 400 - 405