High-pitch, high temporal resolution, multi-energy cardiac imaging on a dual-source photon-counting-detector CT

被引:9
|
作者
Ahmed, Zaki [1 ]
Campeau, David [2 ]
Gong, Hao [1 ]
Rajendran, Kishore [1 ]
Rajiah, Prabhakar [1 ]
McCollough, Cynthia
Leng, Shuai [3 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN USA
[2] Mayo Clin, Dept Physiol & Biomed Engn, Rochester, MN USA
[3] 200 First St SW, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
cardiac CT; computed tomography; dual energy CT; iodine quantification; material decomposition; motion artifact; photon counting detector; COMPUTED-TOMOGRAPHY; ENERGY CT; ANGIOGRAPHY; RECONSTRUCTION; QUALITY;
D O I
10.1002/mp.16124
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveTo measure the accuracy of material decomposition using a dual-source photon-counting-detector (DS-PCD) CT operated in the high-pitch helical scanning mode and compare the results against dual-source energy-integrating-detector (DS-EID) CT, which requires use of a low-pitch value in dual-energy mode. MethodsA DS-PCD CT and a DS-EID CT were used to scan a cardiac motion phantom consisting of a 3-mm diameter iodine cylinder. Iodine maps were reconstructed using DS-PCD in high-pitch mode and DS-EID in low-pitch mode. Image-based circularity, diameter, and iodine concentration of the iodine cylinder were calculated and compared between the two scanners. With institutional review board approval, in vivo exams were performed with the DS-PCD CT in high-pitch mode. Images were qualitatively compared against patients with similar heart rates that were scanned with DS-EID CT in low-pitch dual-energy mode. ResultsOn iodine maps, the mean circularity was 0.97 +/- 0.02 with DS-PCD in high-pitch mode and 0.95 +/- 0.06 with DS-EID in low-pitch mode. The mean diameter was 2.9 +/- 0.2 mm with DS-PCD and 3.1 +/- 0.2 mm with DS-EID, both of which are close to the 3 mm ground truth. For DS-PCD, the mean iodine concentration was 9.6 +/- 0.8 mg/ml and this was consistent with the 9.4 +/- 0.6 mg/ml value obtained with the cardiac motion disabled. For DS-EID, the concentration was 12.7 +/- 1.2 mg/ml with motion enabled and 11.7 +/- 0.5 mg/ml disabled. The background noise in the iodine maps was 15.1 HU with DS-PCD and 14.4 HU with DS-EID, whereas the volume CT dose index (CTDIvol) was 3 mGy with DS-PCD and 11 mGy with DS-EID. On comparison of six patients (three on PCD, three on EID) with similar heart rates, DS-PCD provided iodine maps with well-defined coronaries even at a high heart rate of 86 beats per minute. Meanwhile, there were substantial motion artifacts in iodine maps obtained with DS-EID for patients with similar heart rates. ConclusionIn a cardiac motion phantom, DS-PCD CT can perform accurate material decomposition in high-pitch mode, providing iodine maps with excellent geometric accuracy and robustness to motion at approximately 38% of the dose for similar noise as DS-EID CT.
引用
下载
收藏
页码:1428 / 1435
页数:8
相关论文
共 50 条
  • [21] Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning
    Bischoff, Bernhard
    Meinel, Felix G.
    Reiser, Maximilian
    Becker, Hans-Christoph
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05): : 1159 - 1165
  • [22] Preliminary Evaluation of High-Pitch, Dual-Source CT Enterography for Radiation Exposure Reduction
    Horst, N.
    Boulter, D.
    Mayes, N.
    Hardie, A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [23] High-pitch dual-source CT coronary angiography with low volumes of contrast medium
    Alexander Lembcke
    Carsten Schwenke
    Patrick A. Hein
    Gesine Knobloch
    Tahir Durmus
    Bernd Hamm
    Alexander Huppertz
    European Radiology, 2014, 24 : 120 - 127
  • [24] Classification of Urinary Stone Composition with a Photon-Counting-Detector CT System Used in a Simulated Dual-Source Acquisition Mode
    Michalak, G.
    Ren, L.
    Ferrero, A.
    Leng, S.
    McCollough, C.
    MEDICAL PHYSICS, 2019, 46 (06) : E409 - E410
  • [25] High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates
    Robert Goetti
    Gudrun Feuchtner
    Paul Stolzmann
    Lotus Desbiolles
    Michael Alexander Fischer
    Christoph Karlo
    Stephan Baumueller
    Hans Scheffel
    Hatem Alkadhi
    Sebastian Leschka
    European Radiology, 2010, 20 : 2565 - 2571
  • [26] Feasibility of high-pitch dual-source low-dose chest CT: Reduction of radiation and cardiac artifacts
    Lim, H. K.
    Ha, H. I.
    Hwang, H. J.
    Lee, K.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (04) : 443 - 449
  • [27] High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates
    Goetti, Robert
    Feuchtner, Gudrun
    Stolzmann, Paul
    Desbiolles, Lotus
    Fischer, Michael Alexander
    Karlo, Christoph
    Baumueller, Stephan
    Scheffel, Hans
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2010, 20 (11) : 2565 - 2571
  • [28] Cardiac spiral dual-source CT with high pitch: a feasibility study
    Ertel, Dirk
    Lell, Michael M.
    Harig, Frank
    Flohr, Thomas
    Schmidt, Bernhard
    Kalender, Willi A.
    EUROPEAN RADIOLOGY, 2009, 19 (10) : 2357 - 2362
  • [29] Cardiac spiral dual-source CT with high pitch: a feasibility study
    Dirk Ertel
    Michael M. Lell
    Frank Harig
    Thomas Flohr
    Bernhard Schmidt
    Willi A. Kalender
    European Radiology, 2009, 19 : 2357 - 2362
  • [30] Vascular imaging findings with high-pitch low-dose dual-source CT in atypical Kawasaki disease
    Kantarci, Mecit
    Guven, Elif
    Ceviz, Naci
    Ogul, Hayri
    Sade, Recep
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2019, 25 (01) : 50 - 54