Comparison of four commercial dose calculation algorithms in different evaluation tests

被引:3
|
作者
Rostami, Aram [1 ]
De Castro Neto, Aluisio Jose [1 ]
Paloor, Satheesh Prasad [1 ]
Khalid, Abdul Sattar [1 ]
Hammoud, Rabih [1 ]
机构
[1] Natl Ctr Canc Care & Res, Dept Radiat Oncol, Doha, Qatar
关键词
Treatment Planning System (TPS); Anisotropic Analytical Algorithm (AAA); Acuros (AXB); collapsed cone; convolution (CCC); Monte Carlo (MC); TREATMENT PLANNING SYSTEM; MONTE-CARLO; CLINICAL IMPLEMENTATION; DOSIMETRIC ACCURACY; ACUROS XB; PHOTON; VALIDATION; ENERGY; VERIFICATION; RADIOTHERAPY;
D O I
10.3233/XST-230079
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Accurate and fast dose calculation is crucial in modern radiation therapy. Four dose calculation algorithms (AAA, AXB, CCC, and MC) are available in Varian Eclipse and RaySearch Laboratories RayStation Treatment Planning Systems (TPSs). OBJECTIVES: This study aims to evaluate and compare dosimetric accuracy of the four dose calculation algorithms applying to homogeneous and heterogeneous media, VMAT plans (based on AAPM TG-119 test cases), and the surface and buildup regions. METHODS: The four algorithms are assessed in homogeneous (IAEA-TECDOCE 1540) and heterogeneous (IAEATECDOC 1583) media. Dosimetric evaluation accuracy for VMAT plans is then analyzed, along with the evaluation of the accuracy of algorithms applying to the surface and buildup regions. RESULTS: Tests conducted in homogeneous media revealed that all algorithms exhibit dose deviations within 5% for various conditions, with pass rates exceeding 95% based on recommended tolerances. Additionally, the tests conducted in heterogeneous media demonstrate high pass rates for all algorithms, with a 100% pass rate observed for 6MV and mostly 100% pass rate for 15MV, except for CCC, which achieves a pass rate of 94%. The results of gamma index pass rate (GIPR) for dose calculation algorithms in IMRT fields show that GIPR (3%/3 mm) for all four algorithms in all evaluated tests based on TG119, are greater than 97%. The results of the algorithm testing for the accuracy of superficial dose reveal variations in dose differences, ranging from -11.9% to 7.03% for 15MV and -9.5% to 3.3% for 6MV, respectively. It is noteworthy that the AXB and MC algorithms demonstrate relatively lower discrepancies compared to the other algorithms. CONCLUSIONS: This study shows that generally, two dose calculation algorithms (AXB and MC) that calculate dose in medium have better accuracy than other two dose calculation algorithms (CCC and AAA) that calculate dose to water.
引用
收藏
页码:1013 / 1033
页数:21
相关论文
共 50 条
  • [21] A COMPARISON OF DIFFERENT ALGORITHMS FOR CYLINDRICITY EVALUATION
    MURTHY, TSR
    [J]. INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 1982, 22 (04): : 283 - 292
  • [22] A COMPARISON OF DIFFERENT ALGORITHMS FOR CIRCULARITY EVALUATION
    MURTHY, TSR
    [J]. PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1986, 8 (01): : 19 - 23
  • [23] Evaluation and comparison of different segmentation algorithms
    Zhang, YJ
    [J]. PATTERN RECOGNITION LETTERS, 1997, 18 (10) : 963 - 974
  • [24] Comparison of AAA and Acuros XB Dose Calculation Algorithms for SRS
    Yeh, F.
    Adamson, J.
    Wang, Z.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E725 - E725
  • [25] Dosimetric evaluation of the dose calculation accuracy of different algorithms for two different treatment techniques during whole breast irradiation
    Acar, Hilal
    Altinok, Ayse Yildirim
    Cebe, Mehmet Siddik
    [J]. JOURNAL OF RADIATION ONCOLOGY, 2019, 8 (03) : 337 - 347
  • [26] Dosimetric Evaluation of the Dose Calculation Accuracy of Different Algorithms for Two Different Treatment Techniques During Whole Breast Irradiation
    Pacaci, P.
    Cebe, M.
    Mabhouti, H.
    Codel, G.
    Serin, E.
    Sanli, E.
    Kucukmorkoc, E.
    Doyuran, M.
    Kucuk, N.
    Canoglu, D.
    Altinok, A.
    Acar, H.
    Ozkok, H. Caglar
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3351 - 3351
  • [27] Evaluation of calculation algorithms implemented in different commercial planning systems on an anthropomorphic breast phantom using film dosimetry
    Polednik, M.
    Abo, Madyan Y.
    Schneider, F.
    Wolff, D.
    Bannach, B.
    Lambrecht, U.
    Wallin, A.
    Haedinger, U.
    Cwiekala, M.
    Lohr, F.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 104 - 104
  • [28] Evaluation of two generic algorithms for CBCT based dose calculation
    Thing, R.
    Nilsson, R.
    Andersson, S.
    Berg, M.
    Lund, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1252 - S1253
  • [29] New evaluation methodology of dose distributions for advanced calculation algorithms
    Jurado-Bruggeman, D.
    Onses-Segarra, A.
    Munoz-Montplet, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S975 - S976
  • [30] Evaluation of calculation algorithms implemented in different commercial planning systems on an anthropomorphic breast phantom using film dosimetry
    Polednik, Martin
    Madyan, Yasser Abo
    Schneider, Frank
    Wolff, Dirk
    Bannach, Burkhardt
    Lambrecht, Ulrike
    Wallin, Andre
    Cwiekala, Marian
    Maurer, Klaus
    Reif, Florian
    Lohr, Frank
    Wenz, Frederik
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 (12) : 667 - 672