Evaluation of calculation algorithms implemented in different commercial planning systems on an anthropomorphic breast phantom using film dosimetry

被引:22
|
作者
Polednik, Martin
Madyan, Yasser Abo
Schneider, Frank
Wolff, Dirk
Bannach, Burkhardt
Lambrecht, Ulrike
Wallin, Andre
Cwiekala, Marian
Maurer, Klaus
Reif, Florian
Lohr, Frank
Wenz, Frederik
机构
[1] Heidelberg Univ, Univ Mannheim Hosp, Ctr Med Mannheim, Dept Radiat Oncol, Mannheim, Germany
[2] Cairo Univ Hosp, Dept Oncol, NEMROCK, Cairo, Egypt
[3] Univ Dusseldorf Hosp, Dept Radiat Oncol, D-4000 Dusseldorf, Germany
[4] Univ Erlangen Nurnberg Hosp, Dept Radiotherapy, D-8520 Erlangen, Germany
[5] Radioncol Vivantes Hosp, Dept Radiotherapy, Berlin, Germany
[6] Gen Hosp Hagen, Dept Radiotherapy & Radio Oncol, Hagen, Germany
[7] St Vicentius Hosp AG, Dept Radiotherapy & Radiooncol, Heidelberg, Germany
关键词
dose calculation; collapsed cone; CC; pencil beam; PB; film dosimetry;
D O I
10.1007/s00066-007-1775-1
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the accuracy of dose calculation algorithms of different planning systems for postoperative tangential radiotherapy in breast cancer. Material and Methods: On a CT dataset of an anthropomorphic phantom, a structure set of the left lung, clinical target volume (CTV), planning target volume, heart, and external contour were delineated. The dataset was processed by six radiation oncology centers participating in this multicenter dosimetry project. Conventional plans with two tangential wedged fields were generated in MasterPlan (R), Pinnacle (R), Eclipse (R), TMS (R), and PrecisePLAN (R). Plan calculations were done using the beam data of local linacs. The dose distributions were verified under local conditions with Gafchromic (R)-EBT films. Results: In all planning systems, deviations between calculation and measurement were around +/- 3% in the CTV in the measured plane. Only small areas with deviations of +/- 5% were detected. Pencil-beam (PB) calculations overestimated the dose inside the lung by up to 23%. Collapsed cone (CC) underestimated the lung dose by up to 6%. Conclusion: CC calculates the dose distribution more accurately than PB. Inside regions with electron disequilibrium, however, the dose is slightly underestimated.
引用
收藏
页码:667 / 672
页数:6
相关论文
共 50 条
  • [1] Evaluation of calculation algorithms implemented in different commercial planning systems on an anthropomorphic breast phantom using film dosimetry
    Polednik, M.
    Abo, Madyan Y.
    Schneider, F.
    Wolff, D.
    Bannach, B.
    Lambrecht, U.
    Wallin, A.
    Haedinger, U.
    Cwiekala, M.
    Lohr, F.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 104 - 104
  • [2] Evaluation of Calculation Algorithms Implemented in Different Commercial Planning Systems on an Anthropomorphic Breast Phantom Using Film DosimetryFilmdosimetrische Evaluation verschiedener Dosisberechnungsalgorithmen für die konventionelle Bestrahlungstechnik des Mammakarzinoms
    Martin Polednik
    Yasser Abo Madyan
    Frank Schneider
    Dirk Wolff
    Burkhardt Bannach
    Ulrike Lambrecht
    André Wallin
    Marian Cwiekala
    Klaus Maurer
    Florian Reif
    Frank Lohr
    Frederik Wenz
    [J]. Strahlentherapie und Onkologie, 2007, 183 : 667 - 672
  • [3] The evaluation of several commercial IMRT treatment planning systems heterogeneity dose calculation algorithms using an anthropomorphic thorax phantom
    Davidson, S
    Followill, D
    Ibbott, G
    Prado, K
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1988 - 1988
  • [4] Evaluation of different calculation algorithms for breast radiotherapy using film dosimetry
    Taira, A. V.
    Swedler, D.
    Young, L.
    Arbuckle, T.
    Wang, W.
    Kim, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S230 - S230
  • [5] Evaluation and analytical comparison of different 2D and 3D Treatment Planning Systems using dosimetry in anthropomorphic phantom
    Khosravi, H. R.
    Nodehi, M. R. Golrokh
    Asnaashari, Kh
    Mandavi, S. R.
    Shirazi, A. R.
    Gholami, S.
    [J]. MEDICAL PHYSICS, 2012, 39 (07) : 4637 - 4638
  • [6] Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems
    Xing, Aitang
    Arumugam, Sankar
    Deshpande, Shrikant
    George, Armia
    Vial, Philip
    Holloway, Lois
    Goozee, Gary
    [J]. 8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [7] Technical note: Heterogeneity dose calculation accuracy in IMRT: Study of five commercial treatment planning systems using an anthropomorphic thorax phantom
    Davidson, Scott E.
    Popple, Richard A.
    Ibbott, Geoffrey S.
    Followill, David S.
    [J]. MEDICAL PHYSICS, 2008, 35 (12) : 5434 - 5439
  • [8] A Novel Organ Dosimetry in an Anthropomorphic Phantom Using XRQA-2 Radiochromic Film
    Brady, S.
    Yoshizumi, T.
    Toncheva, G.
    Anderson-Evans, C.
    Fredrickson, M.
    Frush, D.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [9] Evaluation of Quantitative Potential of Breast Tomosynthesis Using a Voxelized Anthropomorphic Breast Phantom
    Mehtaji, D.
    Shafer, C.
    Chen, B.
    Lo, J.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3137 - +
  • [10] Evaluation of the detectability of breast cancer lesions using a modified anthropomorphic phantom
    Doshi, NK
    Basic, M
    Cherry, SR
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (11) : 1951 - 1957