Nuclear Overhauser enhancement imaging at-1.6 ppm in rat brain at 4.7T

被引:5
|
作者
Viswanathan, Malvika [1 ,2 ]
Kurmi, Yashwant [1 ,3 ]
Zu, Zhongliang [1 ,2 ,3 ]
机构
[1] Vanderbilt Univ, Med Ctr, Inst Imaging Sci, Nashville, TN USA
[2] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN USA
[3] Vanderbilt Univ, Med Ctr, Dept Radiol & Radiol Sci, Nashville, TN USA
基金
美国国家卫生研究院;
关键词
CEST; NOE; tumor; EXCHANGE SATURATION-TRANSFER; PROTON-TRANSFER APT; IN-VIVO; MAGNETIZATION-TRANSFER; TRANSFER CEST; MOUSE MODEL; AMIDE; NOE; RELAXATION; SIGNAL;
D O I
10.1002/mrm.29896
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A new nuclear Overhauser enhancement (NOE)-mediated saturation transfer signal at around -1.6 ppm, termed NOE(-1.6), has been reported at high fields of 7T and 9.4T previously. This study aims to validate the presence of this signal at a relatively low field of 4.7T and evaluate its variations in different brain regions and tumors.Methods: Rats were injected with monocrystalline iron oxide nanoparticles to reduce the NOE(-1.6) signal. CEST signals were measured using different saturation powers before and after injection to assess the presence of this signal. Multiple-pool Lorentzian fits, with/without inclusion of the NOE(-1.6) pool, were performed on CEST Z-spectra obtained from healthy rat brains and rats with 9L tumors. These fits aimed to further validate the presence of the NOE(-1.6) signal and quantify its amplitude.Results: The NOE(-1.6) signal exhibited a dramatic change following the injection of monocrystalline iron oxide nanoparticles, confirming its presence at 4.7T. The NOE(-1.6) signal reached its peak at a saturation power of similar to 0.75 mu T, indicating an optimized power level. The multiple-pool Lorentzian fit without the NOE(-1.6) pool showed higher residuals around -1.6 ppm compared to the fit with this pool, further supporting the presence of this signal. The NOE(-1.6) signal did not exhibit significant variation in the corpus callosum and caudate putamen regions, but it showed a significant decrease in tumors, which aligns with previous findings at 9.4T.Conclusion: This study successfully demonstrated the presence of the NOE(-1.6) signal at 4.7T, which provides valuable insights into its potential applications at lower field strengths.
引用
收藏
页码:615 / 629
页数:15
相关论文
共 50 条
  • [21] High-Throughput Total Body Dynamic Imaging in a Preclinical PET/MRI 4.7T System
    Zhou, Iris
    Farrar, Christian
    Rotile, Nicholas
    Esfahani, Shadi
    Solsona, Cesar Molinos
    Sasser, Todd
    Heidenreich, Michael
    Caravan, Peter
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [22] 13C MR Imaging of Methionine-rich Gliomas at 4.7T: A Pilot Study
    Sasao, Akira
    Hirai, Toshinori
    Iriguchi, Norio
    Nakamura, Hideo
    Kudo, Mareina
    Sasao, Ako
    Yamashita, Yasuyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2011, 10 (02) : 139 - 142
  • [23] High field strength (4.7T) magnetic resonance imaging of hydrocephalus in an African Grey parrot (Psittacus erithacus)
    Fleming, GJ
    Lester, NV
    Stevenson, R
    Silver, XS
    VETERINARY RADIOLOGY & ULTRASOUND, 2003, 44 (05) : 542 - 545
  • [24] Nuclear Overhauser Enhancement-Mediated Magnetization Transfer Imaging in Glioma with Different Progression at 7 T
    Tang, Xiangyong
    Dai, Zhuozhi
    Xiao, Gang
    Yan, Gen
    Shen, Zhiwei
    Zhang, Tao
    Zhang, Guishan
    Zhuang, Zerui
    Shen, Yuanyu
    Zhang, Zhiyan
    Hu, Wei
    Wu, Renhua
    ACS CHEMICAL NEUROSCIENCE, 2017, 8 (01): : 60 - 66
  • [25] Imaging human teeth by phosphorus magnetic resonance with nuclear Overhauser enhancement
    Yi Sun
    Ole Brauckmann
    Donald R. Nixdorf
    Arno Kentgens
    Michael Garwood
    Djaudat Idiyatullin
    Arend Heerschap
    Scientific Reports, 6
  • [26] T1-weighted cine FLASH is superior to IR imaging of post-infarction myocardial viability at 4.7T
    Thomas, D
    Dumont, C
    Pickup, S
    Misselwitz, B
    Zhou, R
    Horowitz, J
    Ferrari, VA
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2006, 8 (02) : 345 - 352
  • [27] Imaging human teeth by phosphorus magnetic resonance with nuclear Overhauser enhancement
    Sun, Yi
    Brauckmann, Ole
    Nixdorf, Donald R.
    Kentgens, Arno
    Garwood, Michael
    Idiyatullin, Djaudat
    Heerschap, Arend
    SCIENTIFIC REPORTS, 2016, 6
  • [28] Double Band-Pass Birdcage RF Coil for Dual Elements NMR Imaging at 4.7T MRI system
    Ahn, Chang Min
    Sheikh, Faisal Ahmad
    Kim, Yeong Cheol
    Kim, Hyun Deok
    2018 IEEE INTERNATIONAL RF AND MICROWAVE CONFERENCE (RFM 2018), 2018, : 189 - 192
  • [29] Polymer gel dosimetry by nuclear Overhauser enhancement (NOE) magnetic resonance imaging
    Quevedo, Ana
    Luo, Guozhen
    Galhardo, Edvaldo
    Price, Michael
    Nicolucci, Patricia
    Gore, John C.
    Zu, Zhongliang
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15):
  • [30] Nuclear Overhauser Enhancement (NOE) Magnetic Resonance Imaging for Polymer Gel Dosimetry
    Quevedo, A.
    Lu, G.
    Price, M.
    Zu, Z.
    Nicolucci, P.
    Gore, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E613 - E613