Nuclear Overhauser enhancement imaging at-1.6 ppm in rat brain at 4.7T

被引:5
|
作者
Viswanathan, Malvika [1 ,2 ]
Kurmi, Yashwant [1 ,3 ]
Zu, Zhongliang [1 ,2 ,3 ]
机构
[1] Vanderbilt Univ, Med Ctr, Inst Imaging Sci, Nashville, TN USA
[2] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN USA
[3] Vanderbilt Univ, Med Ctr, Dept Radiol & Radiol Sci, Nashville, TN USA
基金
美国国家卫生研究院;
关键词
CEST; NOE; tumor; EXCHANGE SATURATION-TRANSFER; PROTON-TRANSFER APT; IN-VIVO; MAGNETIZATION-TRANSFER; TRANSFER CEST; MOUSE MODEL; AMIDE; NOE; RELAXATION; SIGNAL;
D O I
10.1002/mrm.29896
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A new nuclear Overhauser enhancement (NOE)-mediated saturation transfer signal at around -1.6 ppm, termed NOE(-1.6), has been reported at high fields of 7T and 9.4T previously. This study aims to validate the presence of this signal at a relatively low field of 4.7T and evaluate its variations in different brain regions and tumors.Methods: Rats were injected with monocrystalline iron oxide nanoparticles to reduce the NOE(-1.6) signal. CEST signals were measured using different saturation powers before and after injection to assess the presence of this signal. Multiple-pool Lorentzian fits, with/without inclusion of the NOE(-1.6) pool, were performed on CEST Z-spectra obtained from healthy rat brains and rats with 9L tumors. These fits aimed to further validate the presence of the NOE(-1.6) signal and quantify its amplitude.Results: The NOE(-1.6) signal exhibited a dramatic change following the injection of monocrystalline iron oxide nanoparticles, confirming its presence at 4.7T. The NOE(-1.6) signal reached its peak at a saturation power of similar to 0.75 mu T, indicating an optimized power level. The multiple-pool Lorentzian fit without the NOE(-1.6) pool showed higher residuals around -1.6 ppm compared to the fit with this pool, further supporting the presence of this signal. The NOE(-1.6) signal did not exhibit significant variation in the corpus callosum and caudate putamen regions, but it showed a significant decrease in tumors, which aligns with previous findings at 9.4T.Conclusion: This study successfully demonstrated the presence of the NOE(-1.6) signal at 4.7T, which provides valuable insights into its potential applications at lower field strengths.
引用
收藏
页码:615 / 629
页数:15
相关论文
共 50 条
  • [41] Linear microstrip surface coil for MR imaging of the rat spinal cord at 4.7 T
    M. Burian
    M. Hájek
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2004, 17 : 359 - 362
  • [42] Unsupervised learning for magnetization transfer contrast MR fingerprinting: Application to CEST and nuclear Overhauser enhancement imaging
    Kang, Beomgu
    Kim, Byungjai
    Schar, Michael
    Park, HyunWook
    Heo, Hye-Young
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) : 2040 - 2054
  • [43] Nuclear Overhauser Enhancement Mediated Chemical Exchange Saturation Transfer Imaging at 7 Tesla in Glioblastoma Patients
    Paech, Daniel
    Zaiss, Moritz
    Meissner, Jan-Eric
    Windschuh, Johannes
    Wiestler, Benedikt
    Bachert, Peter
    Neumann, Jan Oliver
    Kickingereder, Philipp
    Schlemmer, Heinz-Peter
    Wick, Wolfgang
    Nagel, Armin Michael
    Heiland, Sabine
    Ladd, Mark Edward
    Bendszus, Martin
    Radbruch, Alexander
    PLOS ONE, 2014, 9 (08):
  • [44] Imaging Amide Proton Transfer and Nuclear Overhauser Enhancement Using Chemical Exchange Rotation Transfer (CERT)
    Zu, Zhongliang
    Xu, Junzhong
    Li, Hua
    Chekmenev, Eduard Y.
    Quarles, C. Chad
    Does, Mark D.
    Gore, John C.
    Gochberg, Daniel F.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (02) : 471 - 476
  • [45] Estimation of Brain Iron Concentration In Vivo Using a Linear Relationship Between Regional Iron and Apparent Transverse Relaxation Rate of the Tissue Water at 4.7T
    Mitsumori, Fumiyuki
    Watanabe, Hidehiro
    Takaya, Nobuhiro
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (05) : 1326 - 1330
  • [46] Isolation of Amide Proton Transfer effect and relayed Nuclear Overhauser Enhancement effect at-3.5ppm Using CEST with Double Saturation Powers
    Zhao, Yu
    Sun, Casey
    Zu, Zhongliang
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (03) : 1025 - 1040
  • [47] HIGH-RESOLUTION NUCLEAR MAGNETIC-RESONANCE IMAGING OF PIG KNEES AT 4.7 T
    ROBINSON, EM
    MACKENZIE, IS
    FREEMONT, A
    JASANI, MK
    MAGNETIC RESONANCE IMAGING, 1988, 6 (05) : 591 - 594
  • [48] A new NOE-mediated MT signal at around-1.6 ppm for detecting ischemic stroke in rat brain
    Zhang, Xiao-Yong
    Wang, Feng
    Afzal, Aqeela
    Xu, Junzhong
    Gore, John C.
    Gochberg, Daniel F.
    Zu, Zhongliang
    MAGNETIC RESONANCE IMAGING, 2016, 34 (08) : 1100 - 1106
  • [49] CD-113 NMR T1 AND NUCLEAR OVERHAUSER ENHANCEMENT MEASUREMENTS ON CADMIUM CYCLOHEXANEDIAMINETETRAACETATE
    BRYDEN, CC
    REILLEY, CN
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1982, 104 (10) : 2697 - 2699
  • [50] Single-shot magnetic resonance imaging of a moving object based on the high-speed spiral-scan echo planner technique at 4.7T
    Lu, G
    Liu, ML
    Li, LY
    Ye, CH
    CHINESE PHYSICS LETTERS, 2002, 19 (09) : 1385 - 1388