Comparing eDQE and eNEQ metrics - is there an alternative approach to assessing image quality in digital mammography?

被引:0
|
作者
Wysocka-Rabin, Anna [1 ]
Dobrzynska, Magdalena [1 ]
Pasicz, Katarzyna [2 ]
Skrzynski, Witold [2 ]
Fabiszewska, Ewa [2 ]
机构
[1] Natl Ctr Nucl Res NCNR, Particle Accelerat Phys & Technol Div, Otwock, Poland
[2] Mar Sklodowska Curie Natl Res Inst Oncol MSCNRIO, Med Phys Dept, Warsaw, Poland
来源
关键词
image quality; digital mammography; effective detective quantum efficiency; effective noise equivalent quanta; DQE; SYSTEMS; SCATTER; MTF;
D O I
10.2478/pjmpe-2023-0018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Early detection of breast cancer requires high-quality mammographic images that have been made possible by the introduction of new technologies, such as full-field digital mammography (FFDM). In this new study, we perform extended measurements to calculate effective detective quantum efficiency (eDQE) and introduce effective noise equivalent quanta (eNEQ). Our aim was to show how these two metrics relate to the image quality of two digital mammography systems.Material and methods: Measurements were performed for a Siemens Mammomat Inspiration and a GE Senographe Pristina system. Each was equipped with an automatic exposure control (AEC) for use in a clinical setting. We used a polymethyl methacrylate (PMMA) phantom at thicknesses of 20, 30, 40 and 70 mm to cover the range of scatter conditions expected in mammography, with and without an anti-scatter grid. The Siemens system had an a-Se detector, and the GE system had an indirect-conversion detector. Measurements of Kerma were performed with Piranha Black 657 meter (RTI Electronics AB). The majority of our calculations were automated, using a modified version of our software.Results: For the two mammographic systems evaluated, we characterized physical quality parameters, such as effective modulation transfer function (eMTF), effective normalized noise power spectrum (eNNPS), eDQE and eNEQ for a wide range of exposures, phantom thicknesses, with and without an anti-scatter grid. Results are presented as a function of spatial frequency. A contrast-detail analysis was performed with a CDMAM 3.4 phantom with dedicated software (CDMAM analysis 1.5.5, NCCPM) and a set of different PMMA phantoms.Conclusions: We successfully demonstrated that the eNEQ metric can be used as a new option to evaluate image quality for images taken with and without a grid and with phantoms of different thicknesses for the Siemens and GE systems. These results were consistent with the results obtained from CDMAM.
引用
收藏
页码:165 / 177
页数:13
相关论文
共 50 条
  • [31] Image and dosimetry quality control for digital mammography by using the Normi Mam Digital phantom
    Calderon-Mata, Angelica
    Arce-Corrales, Luis
    Mejias-Gamboa, Ricardo
    UNICIENCIA, 2018, 32 (02) : 70 - 81
  • [32] Decreased patient dose and improved image quality in digital mammography with Bayesian image estimation
    Baydush, AH
    Floyd, CE
    RADIOLOGY, 2000, 217 : 347 - 347
  • [33] Historical trends in image quality and mean glandular dose in digital mammography
    Mackenzie, Alistair
    Khan, Riyad
    Young, Kenneth C.
    15TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI2020), 2020, 11513
  • [34] Comprehensive assessment of image quality in synthetic and digital mammography: a quantitative comparison
    Barca, Patrizio
    Lamastra, Rocco
    Aringhieri, Giacomo
    Tucciariello, Raffaele Maria
    Traino, Antonio
    Fantacci, Maria Evelina
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (04) : 1141 - 1152
  • [35] Dose sensitivity of three methods of image quality assessment in digital mammography
    Hummel, Johann
    Kaar, Marcus
    Hoffmann, Rainer
    Kaldarar, Heinrich
    Semturs, Friedrich
    Homolka, Peter
    Figl, Michael
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [37] Whole-breast digital mammography: Evaluation of clinical image quality
    Feig, SA
    Yaffe, MJ
    Plewes, DB
    Piccaro, MF
    Jong, RA
    RADIOLOGY, 1996, 201 : 1300 - 1300
  • [38] Image quality and compression force: the forgotten link in optimisation of digital mammography?
    D O'Leary
    T Grant
    L Rainford
    Breast Cancer Research, 13
  • [39] Effect of filter on average glandular dose and image quality in digital mammography
    Songsaeng, C.
    Krisanachinda, A.
    Theerakul, K.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [40] Image quality and compression force: the forgotten link in optimisation of digital mammography?
    O'Leary, D.
    Grant, T.
    Rainford, L.
    BREAST CANCER RESEARCH, 2011, 13