A comparison of the visual performance of refractive rotationally asymmetric multifocal intraocular lenses and trifocal intraocular lenses

被引:0
|
作者
Qiu, Jing-Jing [1 ]
Zhang, Qian [1 ]
Fu, Shu-Hua [1 ]
Huang, Jun-Qi [2 ]
Wang, Zhi-Hong [3 ]
You, Zhi-Peng [1 ]
Liu, Fei [1 ]
Sun, Tao [2 ]
机构
[1] Nanchang Univ, Dept Ophthalmol, Affiliated Hosp 2, Nanchang 330006, Peoples R China
[2] Nanchang Univ, Dept Ophthalmol, Affiliated Eye Hosp, Nanchang 330006, Peoples R China
[3] Dept Jiujiang 1 Peoples Hosp, Ophthalmol, Jiujiang 332000, Peoples R China
关键词
Cataract; Phacoemulsification; Multifocal Lens; Trifocal Lens; Intraocular Lens; BILATERAL IMPLANTATION; OUTCOMES; EXPERIENCE; CATARACT;
D O I
10.1166/mex.2023.2445
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Objective: The aim of this study is to compare the short term visual outcomes and subjective visual quality of the monocular implantation of a refractive rotationally asymmetric multifocal intraocular lens (IOL) (SBL-3, Lenstec, Inc., USA) with those of a trifocalIOL (AT LISA tri 839 MP, Carl Zeiss Meditec, Jena, Germany). IP: 2038 109 20 On: Tue 08 Aug 2023 05:04:48 Methods: This study involved a totalCopyright:of46 Americapatients (46Sc ntificeyes) Pubwith shrsage-related cataracts, who underwent uncomplicated cataract surgery. Twenty-two patients (22 eys) had SBL-3 multifocal IOLs implanted (group Delivered by ngenta A) and 24 patients (24 eyes) had AT LISA tri 839 MPs implanted (group B). The patients were all evaluated three months after surgery. Results: Group B had a significantly better performance (0.127 & PLUSMN; 0.070) logMAR (20/40 Snellen equivalent) than group A (0.25 & PLUSMN; 0.093) LogMAR for monocular UIVA at 80 cm (p < 0.05). There was no statistically significant difference at other distances. The monocular defocus curves showed that group B had a better performance than group A at a vergence of -1.5 D (p < 0.05). Higher-order aberrations (HOAs) were significantly higher in group A (p < 0.05). The SBL-3 IOLs resulted in much lower MTF cut-off (23.68 & PLUSMN; 9.892) cpd and Strehl ratio (0.13 & PLUSMN; 0.052) than trifocal IOLs (MTF cut-off 26.25 & PLUSMN; 8.751 cpd, Strehl ratio 0.15 & PLUSMN; 0.063). But there was no significant difference between the two IOLs (P > 0.05). Complaints of halos at night were made by 37.5% (9/24) of group A and 9.1% (2/22) of group B, but they did not interfere with their vision. All the patients reported a high level of satisfaction and said they no longer needed to use spectacle correction at either far, intermediate or near distances. Conclusions: Both SBL-3 IOLs and AT LISA tri 839 MP trifocal IOLs provided good short-term visual outcomes at all distances postoperatively with a high level of spectacle independence and patient satisfaction. The AT LISA tri 839 MP lens provided better intermediate vision at 80 cm, while similar visual acuity (VA) was reported at other distances.
引用
收藏
页码:1110 / 1115
页数:6
相关论文
共 50 条
  • [31] In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens
    Dominguez-Vicent, Alberto
    Juan Esteve-Taboada, Jose
    Del Aguila-Carrasco, Antonio J.
    Monsalvez-Romin, Daniel
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 138 - 147
  • [32] Comparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench
    Gatinel, Damien
    Houbrechts, Yvette
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (07): : 1093 - 1099
  • [33] Visual Performance of Two Diffractive Trifocal Intraocular Lenses: A Randomized Trial
    Hienert, Julius
    Stjepanek, Kristina
    Hirnschall, Nino
    Ruiss, Manuel
    Zwickl, Hannah
    Findl, Oliver
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (07) : 460 - +
  • [34] Optical performance of multifocal intraocular lenses
    Jacobi, F. K.
    Kessler, W.
    Held, S.
    OPHTHALMOLOGE, 2007, 104 (03): : 236 - 242
  • [35] Visual performance: Comparison of foldable intraocular lenses
    Bhattacharjee, H
    Bhattacharjee, K
    Medhi, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (03): : 451 - 455
  • [36] MULTIFOCAL INTRAOCULAR LENSES
    DUFFEY, RJ
    ZABEL, RW
    LINDSTROM, RL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (04): : 423 - 429
  • [37] Multifocal intraocular lenses
    Shajari, Mehdi
    Mayer, Wolfgang J.
    Priglinger, Siegfried
    Kreutzer, Thomas
    SPEKTRUM DER AUGENHEILKUNDE, 2019, 33 (06) : 165 - 168
  • [38] Intraocular multifocal lenses
    Pieh S.
    Spektrum der Augenheilkunde, 2016, 30 (6) : 213 - 216
  • [39] Multifocal intraocular lenses
    Auffarth, G. U.
    OPHTHALMOLOGE, 2008, 105 (06): : 521 - 521
  • [40] Visual function comparison of 2 aspheric multifocal intraocular lenses
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Blazquez, Jose I.
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02): : 242 - 248