Optical performance of multifocal intraocular lenses

被引:0
|
作者
Jacobi, F. K.
Kessler, W.
Held, S.
机构
[1] Ambulantes Zentrum Augenoperat, D-35394 Giessen, Germany
[2] Zentrum Augenheilkunde, Giessen, Germany
来源
OPHTHALMOLOGE | 2007年 / 104卷 / 03期
关键词
multifocal intraocular lenses; contrast sensitivity; optical performance; optical bench; simulation study;
D O I
10.1007/s00347-006-1452-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Reduced contrast sensitivity, glare disability and insufficient bifocality are the main drawbacks of multifocal intraocular lenses (IOL). The bilateral implantation of diffractive IOL with an asymmetrical light distribution for distance and near focus is an alternative concept that aims to improve the contrast sensitivity and bifocality of conventional multifocal IOL. The optical performance of monofocal (PhacoFlexII SI40) and multifocal IOL (Array SA40N; Acri.Twin 737D/733D) was quantitatively assessed in 18 healthy probands and qualitatively determined by digital photographic recording using an optical apparatus, the "physical eye", according to Reiner and Jacobi. Vision examination included standard tests of distance and near visual acuity, contrast sensitivity and low contrast visual acuity testing under varying pupil size using a video acuity tester. Distance visual acuity was significantly superior with the SI40 and distant-dominant 737D compared to the SA40N and near-dominant 733D. At near, the 733D had the best performance. Contrast sensitivity was better with the 737D than the SA40N when both were compared with the SI40. No normal contrast sensitivity could be determined with the 733D because of the optical phenomenon of 'spurious resolution'. Variation in pupil size had less impact on contrast acuity with the Acri.Twin IOL compared to the SI40 and SA40N. Photographic testing revealed better edge contrast with the Acri.Twin than the SA40N. The optical performance of multifocal IOL correlates with the properties of physical light distribution. Differences in edge contrast may be discerned using photographic recording.
引用
收藏
页码:236 / 242
页数:7
相关论文
共 50 条
  • [1] OPTICAL-PERFORMANCE OF MULTIFOCAL INTRAOCULAR LENSES
    HOLLADAY, JT
    VANDIJK, H
    LANG, A
    PORTNEY, V
    WILLIS, TR
    SUN, R
    OKSMAN, HC
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (04): : 413 - 422
  • [2] Visual and optical performance with hybrid multifocal intraocular lenses
    Madrid-Costa, David
    Cervino, Alejandro
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Montes-Mico, Robert
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2010, 93 (06) : 426 - 440
  • [3] Assessing the optical performance of multifocal (diffractive) intraocular lenses
    Simpson, Michael J.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (02) : 207 - 207
  • [4] Optical performance of monofocal versus multifocal intraocular lenses
    Gatinel, Damien
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11): : 1817 - 1818
  • [5] Effect of Decentration on the Optical Performance in Multifocal Intraocular Lenses
    Soda, Mitsutaka
    Yaguchi, Shigeo
    OPHTHALMOLOGICA, 2012, 227 (04) : 197 - 204
  • [6] Assessing the optical performance of multifocal (diffractive) intraocular lenses
    Eppig, Timo
    Scholz, Katja
    Langenbucher, Achim
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2008, 28 (05) : 467 - 474
  • [7] Optical performance of monofocal and multifocal intraocular lenses in the human eye
    Ortiz, Dolores
    Alio, Jorge L.
    Bernabeu, Gonzalo
    Pongo, Vanessa
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (05): : 755 - 762
  • [8] Optical Performance in ReZoom and Array Multifocal Intraocular Lenses In Vitro
    Kawamorita, Takushi
    Uozato, Hiroshi
    Aizawa, Daisuke
    Kamiya, Kazutaka
    Shimizu, Kimiya
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (05) : 467 - 469
  • [9] Optical performance of monofocal versus multifocal intraocular lenses REPLY
    Ortiz, Dolores
    Alio, Jorge L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (11): : 1818 - 1818
  • [10] Clinical outcomes and optical performance of four different multifocal intraocular lenses
    Bostanci Ceran, Basak
    Takmaz, Tamer
    Can, Izzet
    Demirok, Gulizar
    Uysal, Betul Seher
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2016, 46 (03) : 597 - 603