Comparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench

被引:145
|
作者
Gatinel, Damien [1 ,2 ]
Houbrechts, Yvette [3 ]
机构
[1] Fdn Ophtalmol Adolphe de Rothschild, F-75940 Paris 19, France
[2] Ctr Expertise & Res Opt Clinicians, Paris, France
[3] Univ Liege, Ctr Spatial Liege, Liege, Belgium
来源
关键词
EYE MODEL; PERFORMANCE; QUALITY; IMAGE; DISTANCE;
D O I
10.1016/j.jcrs.2013.01.048
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the differences in optical performance of 9 multifocal IOLs using the same optical bench and to propose a possible comparison for surgeons. SETTING: Rothschild Foundation, Paris, France. DESIGN: Experimental study. METHODS: Nine IOLs (Acrysof Restor +3.0 diopter [D] SN6AD1, Acrysof Restor +4.0 D SN60D3, Acrysof aspheric monofocal SN60WF, Acri.Lisa 366D, Finevision Micro F, Tecnis ZM900, and Rezoom, Diffractiva Diff-s, and Lentis Mplus +3.0 D) were tested using the same optical bench that complies with International Organization for Standardization standard 11979 requirements. The through-focus modulation transfer functions (MTFs) were compared, and the image of the United States Air Force (USAF) target was taken while each IOL was at far, intermediate, and near focal points. RESULTS: The through-focus MTF of the trifocal IOL showed a peak in the intermediate range that was not present with monofocal and bifocal IOLs. The USAF target images showed similar resolution with all IOLs for far focal points. Diffractive IOLs showed better resolution for near focal points, and the only sharp image in the intermediate range was obtained using the trifocal IOL. CONCLUSION: There was a significant difference in the degree of near, intermediate, and distance quality of the image with the various types of multifocal IOLs in vitro. Intermediate vision was more prominent with the trifocal IOL. (C) 2013 ASCRS and ESCRS
引用
收藏
页码:1093 / 1099
页数:7
相关论文
共 50 条
  • [1] Comparison of visual performance between diffractive bifocal and diffractive trifocal intraocular lenses
    Junya Kawamura
    Hirotaka Tanabe
    Tomohiro Shojo
    Tomofusa Yamauchi
    Kosuke Takase
    Hitoshi Tabuchi
    [J]. Scientific Reports, 14
  • [2] Comparison of visual performance between diffractive bifocal and diffractive trifocal intraocular lenses
    Kawamura, Junya
    Tanabe, Hirotaka
    Shojo, Tomohiro
    Yamauchi, Tomofusa
    Takase, Kosuke
    Tabuchi, Hitoshi
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01)
  • [3] Psychophysical Vision Simulation of Diffractive Bifocal and Trifocal Intraocular Lenses
    Brezna, Wolfgang
    Lux, Kirsten
    Dragostinoff, Nikolaus
    Krutzler, Christian
    Plank, Nicole
    Tobisch, Rainer
    Boltz, Agnes
    Garhoefer, Gerhard
    Told, Reinhard
    Witkowska, Katarzyna
    Schmetterer, Leopold
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2016, 5 (05):
  • [4] Clinical Outcomes of Patients Fitted with Bifocal and Trifocal Diffractive Intraocular Lenses
    Seo, Jeong Gi
    Choi, Moon Jung
    Seo, Kyoung Yul
    Kim, Eung Kweon
    Kim, Tae Im
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2018, 59 (04): : 325 - 331
  • [5] Methods for investigating optical characteristics of bifocal diffractive-refractive intraocular lenses
    G. A. Lenkova
    [J]. Optoelectronics, Instrumentation and Data Processing, 2007, 43 (3) : 262 - 273
  • [6] Methods for Investigating Optical Characteristics of Bifocal Diffractive-Refractive Intraocular Lenses
    Lenkova, G. A.
    [J]. OPTOELECTRONICS INSTRUMENTATION AND DATA PROCESSING, 2007, 43 (03) : 262 - 273
  • [7] OPTICAL-PROPERTIES OF DIFFRACTIVE, BIFOCAL, INTRAOCULAR LENSES
    LARSSON, M
    BECKMAN, C
    NYSTROM, A
    HARD, S
    SJOSTRAND, J
    [J]. APPLIED OPTICS, 1992, 31 (13) : 2377 - 2384
  • [8] Optical bench performance of 3 trifocal intraocular lenses
    Carson, Daniel
    Xu, Zaiwei
    Alexander, Elsinore
    Choi, Myoung
    Zhao, Zeyu
    Hong, Xin
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (09): : 1361 - 1367
  • [9] Depth of focus in eyes with diffractive bifocal and refractive multifocal intraocular lenses
    Schmidinger, Gerald
    Geitzenauer, Wolfgang
    Hahsle, Bernhard
    Klemen, Ulrich-Michael
    Skorpik, Christian
    Pieh, Stefan
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (10): : 1650 - 1656
  • [10] Optical testing of bifocal diffractive-refractive intraocular lenses using Shack-Hartmann wavefront sensor
    Gutman, A. S.
    Shchesyuk, I. V.
    Korolkov, V. P.
    [J]. OPTICAL MICRO- AND NANOMETROLOGY III, 2010, 7718