Comparison of the Sensor-Augmented Pump System with the Advanced Hybrid Closed-Loop Delivery System: Quality of Life, Diabetes Distress, and Glycaemic Outcomes in a Real-Life Context

被引:2
|
作者
Benioudakis, Emmanouil S. [1 ]
Karlafti, Eleni [1 ]
Kalaitzaki, Argyroula [2 ]
Kalpou, Maria-Alexandra [3 ]
Georgiou, Evangelos D. [4 ]
Savopoulos, Christos [1 ]
Didangelos, Triantafyllos [1 ]
机构
[1] Aristotle Univ Thessaloniki, Diabet Ctr, Propaedeut Dept Internal Med 1, Med Sch ,AHEPA Gen Univ Hosp, Thessaloniki, Greece
[2] Hellen Mediterranean Univ, Hlth Sci Fac, Lab Interdisciplinary Approaches Enhancement Qual, Dept Social Work, Iraklion, Greece
[3] Natl & Kapodistrian Univ Athens, Dept Psychol, Athens, Greece
[4] Univ Cyprus, Univ Ctr Field Studies, Dept Psychol, Nicosia, Cyprus
关键词
Type 1 diabetes mellitus; Advanced hybrid closed-loop; Sensor-augmented pump; Quality of life; Glycaemic outcomes; Diabetes distress; SUBCUTANEOUS INSULIN INFUSION; TYPE-1; TARGETS; ADULTS;
D O I
10.2174/1573399820666230531161858
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Type 1 diabetes mellitus (T1D) is a chronic disease that requires exogenous insulin administration and intensive management to prevent any complications. Recent innovations in T1D management technologies include the Advanced Hybrid Closed-Loop delivery system (AHCL). The pioneer AHCL system provides automated basal and automated bolus corrections when neededObjectives This study aimed to compare the Advanced Hybrid Closed-Loop (AHCL) system and the Sensor-Augmented Pump (SAP) with Predictive Low Glucose Management (PLGM) system, in relation to glycaemic outcomes, general and diabetes-related Quality of Life (QoL), and diabetes distress.Methods General and diabetes-related QoL were assessed with the Diabetes Quality of Life Brief Clinical Inventory (DQOL-BCI) and the World Health Organization Quality of Life-BREF (WHOQOL-BREF), respectively. Diabetes distress was assessed with the Diabetes Distress Scale for Type 1 diabetes (T1-DDS).Results Eighty-nine T1D adults participated in the study, mostly females (65.2%), with a mean age of 39.8 (& PLUSMN; 11.5 years). They had on average 23 years of diabetes (& PLUSMN; 10.7) and they were on continuous subcutaneous insulin infusion therapy. Significant differences favoring the AHCL over the SAP + PLGM system were demonstrated by lower mean glucose levels, less time above range, lower scores on DQOL-BCI, T1-DDS, and higher scores on WHOQOL-BREF. Finally, the linear regression models revealed the association of time in range in most of the above aspects.Conclusion This study highlighted the advantages of the AHCL system over the SAP + PLGM system in the real-world setting in relation to general and diabetes-related QoL, diabetes distress, and glycaemic outcomes.
引用
收藏
页码:49 / 58
页数:10
相关论文
共 50 条
  • [1] Long-term real-life glycaemic outcomes with a hybrid closed-loop system compared with sensor-augmented pump therapy in patients with type 1 diabetes
    Akturk, Halis Kaan
    Giordano, Dominique
    Champakanath, Anagha
    Brackett, Scott
    Garg, Satish
    Snell-Bergeon, Janet
    [J]. DIABETES OBESITY & METABOLISM, 2020, 22 (04): : 583 - 589
  • [2] Faster insulin action is associated with improved glycaemic outcomes during closed-loop insulin delivery and sensor-augmented pump therapy in adults with type 1 diabetes
    Ruan, Yue
    Thabit, Hood
    Leelarathna, Lalantha
    Hartnell, Sara
    Wilinska, Malgorzata E.
    Tauschmann, Martin
    Dellweg, Sibylle
    Benesch, Carsten
    Mader, Julia K.
    Holzer, Manuel
    Kojzar, Harald
    Evans, Mark L.
    Pieber, Thomas R.
    Arnolds, Sabine
    Hovorka, Roman
    [J]. DIABETES OBESITY & METABOLISM, 2017, 19 (10): : 1485 - 1489
  • [3] A randomised clinical trial comparing the efficacy of a hybrid closed-loop automated insulin delivery system with a sensor-augmented disposable patch pump in type 1 diabetes
    Kim, J.
    Jin, S. -M.
    Kang, E.
    Kwak, S.
    Yang, Y.
    Yoo, J.
    Bae, J.
    Moon, J.
    Jung, C.
    Bae, J.
    Suh, S.
    Moon, S.
    Song, S.
    Chon, S.
    Kim, J.
    [J]. DIABETOLOGIA, 2023, 66 (SUPPL 1) : S388 - S388
  • [4] Sleep Quality and Quantity in Caregivers of Children with Type 1 Diabetes Using Closed-Loop Insulin Delivery or a Sensor-Augmented Pump
    Madrid-Valero, Juan J.
    Ware, Julia
    Allen, Janet M.
    Boughton, Charlotte K.
    Hartnell, Sara
    Wilinska, Malgorzata E.
    Thankamony, Ajay
    de Beaufort, Carine
    Schierloh, Ulrike
    Campbell, Fiona M.
    Sibayan, Judy
    Bocchino, Laura E.
    Kollman, Craig
    Hovorka, Roman
    Gregory, Alice M.
    Consortium, KidsAP
    [J]. PEDIATRIC DIABETES, 2023, 2023
  • [5] LONG-TERM GLYCAEMIC OUTCOMES OF AN ADVANCED HYBRID CLOSED-LOOP SYSTEM
    Beato-Vibora, P. I.
    Lopez, A. Ambrojo
    Fernandez-Bueso, M. M.
    Gil-Poch, E.
    Arroyo-Diez, F. J.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A106 - A107
  • [6] Comparison Between Closed-Loop Insulin Delivery System (the Artificial Pancreas) and Sensor-Augmented Pump Therapy: A Randomized-Controlled Crossover Trial
    Haidar, Ahmad
    Legault, Laurent
    Raffray, Marie
    Gouchie-Provencher, Nikita
    Jacobs, Peter G.
    El-Fathi, Anas
    Rutkowski, Joanna
    Messier, Virginie
    Rabasa-Lhoret, Remi
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (03) : 168 - 174
  • [7] Hybrid closed Loop improved glucose control compared to sensor-augmented pumps in outpatients with type 1 diabetes in real-life conditions with telehealth monitoring
    C. Thivolet
    M. Gaudilliere
    S. Villar Fimbel
    N. Bendelac
    B. Mestre
    N. Protsenko
    S. Brunot
    M. Nicolino
    [J]. Acta Diabetologica, 2022, 59 : 395 - 401
  • [8] Hybrid closed Loop improved glucose control compared to sensor-augmented pumps in outpatients with type 1 diabetes in real-life conditions with telehealth monitoring
    Thivolet, C.
    Gaudilliere, M.
    Villar Fimbel, S.
    Bendelac, N.
    Mestre, B.
    Protsenko, N.
    Brunot, S.
    Nicolino, M.
    [J]. ACTA DIABETOLOGICA, 2022, 59 (03) : 395 - 401
  • [9] Sensor-augmented pump therapy in real-life: patients reported outcomes results of the INTERPRET observational study
    Norgaard, K.
    Scaramuzza, A.
    Bratina, N.
    Lalic, N.
    Jarosz-Chobot, P.
    Kocsis, G.
    Verkauskiene, R.
    De Block, C.
    Carrette, O.
    de Portu, S.
    Castaneda, J.
    Cohen, O.
    [J]. DIABETOLOGIA, 2012, 55 : S434 - S435
  • [10] Glycemic Control and Change in Insulin Dose with Real-Life Use of Hybrid Closed-Loop System
    Giordano, Dominique A.
    Snell-Bergeon, Janet K.
    Joseph, Hal
    Garg, Satish K.
    Akturk, Halis K.
    [J]. DIABETES, 2019, 68