Hybrid closed Loop improved glucose control compared to sensor-augmented pumps in outpatients with type 1 diabetes in real-life conditions with telehealth monitoring

被引:6
|
作者
Thivolet, C. [1 ]
Gaudilliere, M. [1 ]
Villar Fimbel, S. [1 ]
Bendelac, N. [1 ]
Mestre, B. [1 ]
Protsenko, N. [1 ]
Brunot, S. [1 ]
Nicolino, M. [1 ]
机构
[1] Hosp Civils Lyon, DIAB eCARE Diabet Ctr, Lyon, France
关键词
Insulin pump; Outpatient; Type; 1; diabetes; Telemedicine; SUBCUTANEOUS INSULIN INFUSION; GLYCEMIC CONTROL; INJECTIONS; HYPOGLYCEMIA; METAANALYSIS; EFFICACY;
D O I
10.1007/s00592-021-01820-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The study aims at evaluating glucose metrics and HbA1C values after pump initiation in outpatient settings. Research design and methods This single center observational study enrolled 121 subjects with type 1 diabetes between September 2020 and May 2021 initiating sensor-augmented pump therapy with stand-alone CGM (n = 26) or pump users who only changed their device (n = 51), with predictive low glucose management (n = 8) or with Hybrid Closed Loop using Medtronic 780G (n = 36) systems. Changes in HbA1C levels and glucose metrics were analyzed after 3 months. All subjects received diabetes and carbohydrate-counting education if needed at time of initiation and were proposed a telehealth monitoring by a diabetic nurse educator. Results There was no episodes of severe hypoglycemia or diabetic ketoacidosis nor serious pump-related adverse events despite outpatient model of care. While only 18/121 (14.8%) participants reached initially the recommended HbA1C levels, 23/85 (27%) in the conventional group and 33/36 (91%) subjects in the Hybrid Closed Loop group reached target levels after 3 months of follow-up. Time in target range 3.9-10 mmol/L (70-180 mg/dl) also improved and was optimal with closed loop with 30/36 (83%) subjects with time in range above 70%. Conclusions Initiation of insulin pump therapy for outpatients is safe with a dedicated facility. Telehealth monitoring after outpatient initiation provides tools for improvement in glucose control with an insulin pump. Outpatient pump initiation is compatible with Hybrid Closed Loop systems which provide the largest improvements in glucose control.
引用
收藏
页码:395 / 401
页数:7
相关论文
共 50 条
  • [1] Hybrid closed Loop improved glucose control compared to sensor-augmented pumps in outpatients with type 1 diabetes in real-life conditions with telehealth monitoring
    C. Thivolet
    M. Gaudilliere
    S. Villar Fimbel
    N. Bendelac
    B. Mestre
    N. Protsenko
    S. Brunot
    M. Nicolino
    [J]. Acta Diabetologica, 2022, 59 : 395 - 401
  • [2] Long-term real-life glycaemic outcomes with a hybrid closed-loop system compared with sensor-augmented pump therapy in patients with type 1 diabetes
    Akturk, Halis Kaan
    Giordano, Dominique
    Champakanath, Anagha
    Brackett, Scott
    Garg, Satish
    Snell-Bergeon, Janet
    [J]. DIABETES OBESITY & METABOLISM, 2020, 22 (04): : 583 - 589
  • [3] Hybrid Closed Loop Overcomes the Impact of Missed or Suboptimal Meal Boluses on Glucose Control in Children with Type 1 Diabetes Compared to Sensor-Augmented Pump Therapy
    Coutant, Regis
    Bismuth, Elise
    Bonnemaison, Elisabeth
    Dalla-Vale, Fabienne
    Morinais, Paul
    Perrard, Maelys
    Trely, Jeanne
    Faure, Nathalie
    Bouhours-Nouet, Natacha
    Levaillant, Lucie
    Farret, Anne
    Storey, Caroline
    Donzeau, Aurelie
    Poidvin, Amelie
    Amsellem-Jager, Jessica
    Place, Jerome
    Quemener, Emmanuel D.
    Hamel, Jean Francois
    Breton, Marc
    Tubiana-Rufi, Nadia
    Renard, Eric
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 (06) : 395 - 403
  • [4] Comparison of the Sensor-Augmented Pump System with the Advanced Hybrid Closed-Loop Delivery System: Quality of Life, Diabetes Distress, and Glycaemic Outcomes in a Real-Life Context
    Benioudakis, Emmanouil S.
    Karlafti, Eleni
    Kalaitzaki, Argyroula
    Kalpou, Maria-Alexandra
    Georgiou, Evangelos D.
    Savopoulos, Christos
    Didangelos, Triantafyllos
    [J]. CURRENT DIABETES REVIEWS, 2024, 20 (03) : 49 - 58
  • [5] HYBRID CLOSED-LOOP GLUCOSE CONTROL COMPARED WITH SENSOR AUGMENTED PUMP THERAPY IN OLDER ADULTS WITH TYPE 1 DIABETES: A MULTICENTRE, MULTINATIONAL, RANDOMISED, CROSSOVER STUDY
    Boughton, C.
    Hartnell, S.
    Thabit, H.
    Mubita, W.
    Draxlbauer, K.
    Poettler, T.
    Wilinska, M.
    Hood, K.
    Mader, J.
    Narendran, P.
    Leelarathna, L.
    Evans, M.
    Hovorka, R.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A54 - A55
  • [6] Continuous home monitoring of glucose - Improved glycemic control with real-life use of continuous glucose sensors in adult subjects with type 1 diabetes
    Garg, Satish K.
    Kelly, William C.
    Voelmle, Mary K.
    Ritchie, Peter J.
    Gottlieb, Peter A.
    McFann, Kim K.
    Ellis, Samuel L.
    [J]. DIABETES CARE, 2007, 30 (12) : 3023 - 3025
  • [7] Real-world outcomes of two different sensor-augmented insulin pumps with predictive low glucose suspend function in type 1 diabetes patients
    Moreno-Fernandez, J.
    Beato-Vibora, P.
    Olvera, P.
    Garcia-Seco, J. A.
    Gallego-Gamero, F.
    Herrera, M. T.
    Munoz-Rodriguez, J. R.
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2021, 181
  • [8] EVALUATION OF HYBRID CLOSED-LOOP INSULIN DELIVERY IN PATIENTS WITH TYPE 1 DIABETES IN REAL-LIFE CONDITIONS: PREVIOUSLY USED THERAPY MATTERS ?
    Carnero, R.
    Rubin, G.
    Dain, A.
    Lequi, L.
    Saleme, A.
    Moretti, C.
    Vettore, M.
    Reynoso, N.
    Roldan, M.
    Charelli, C.
    Lopez Avila Carolina, C.
    Demarchi, M.
    Bringas, L.
    Vianco, A.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A168 - A169
  • [9] Comparison of two advanced hybrid closed loop in a pediatric population with type 1 diabetes: a real-life observational study
    R. Schiaffini
    A. Deodati
    M. C. Nicoletti
    C. Carducci
    P. Ciampalini
    A. Lorubbio
    M. C. Matteoli
    V. Pampanini
    I. P. Patera
    N. Rapini
    S. Cianfarani
    [J]. Acta Diabetologica, 2022, 59 : 959 - 964
  • [10] Comparison of two advanced hybrid closed loop in a pediatric population with type 1 diabetes: a real-life observational study
    Schiaffini, R.
    Deodati, A.
    Nicoletti, M. C.
    Carducci, C.
    Ciampalini, P.
    Lorubbio, A.
    Matteoli, M. C.
    Pampanini, V
    Patera, I. P.
    Rapini, N.
    Cianfarani, S.
    [J]. ACTA DIABETOLOGICA, 2022, 59 (07) : 959 - 964