Comparison of the Sensor-Augmented Pump System with the Advanced Hybrid Closed-Loop Delivery System: Quality of Life, Diabetes Distress, and Glycaemic Outcomes in a Real-Life Context

被引:4
|
作者
Benioudakis, Emmanouil S. [1 ]
Karlafti, Eleni [1 ]
Kalaitzaki, Argyroula [2 ]
Kalpou, Maria-Alexandra [3 ]
Georgiou, Evangelos D. [4 ]
Savopoulos, Christos [1 ]
Didangelos, Triantafyllos [1 ]
机构
[1] Aristotle Univ Thessaloniki, Diabet Ctr, Propaedeut Dept Internal Med 1, Med Sch ,AHEPA Gen Univ Hosp, Thessaloniki, Greece
[2] Hellen Mediterranean Univ, Hlth Sci Fac, Lab Interdisciplinary Approaches Enhancement Qual, Dept Social Work, Iraklion, Greece
[3] Natl & Kapodistrian Univ Athens, Dept Psychol, Athens, Greece
[4] Univ Cyprus, Univ Ctr Field Studies, Dept Psychol, Nicosia, Cyprus
关键词
Type 1 diabetes mellitus; Advanced hybrid closed-loop; Sensor-augmented pump; Quality of life; Glycaemic outcomes; Diabetes distress; SUBCUTANEOUS INSULIN INFUSION; TYPE-1; TARGETS; ADULTS;
D O I
10.2174/1573399820666230531161858
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Type 1 diabetes mellitus (T1D) is a chronic disease that requires exogenous insulin administration and intensive management to prevent any complications. Recent innovations in T1D management technologies include the Advanced Hybrid Closed-Loop delivery system (AHCL). The pioneer AHCL system provides automated basal and automated bolus corrections when neededObjectives This study aimed to compare the Advanced Hybrid Closed-Loop (AHCL) system and the Sensor-Augmented Pump (SAP) with Predictive Low Glucose Management (PLGM) system, in relation to glycaemic outcomes, general and diabetes-related Quality of Life (QoL), and diabetes distress.Methods General and diabetes-related QoL were assessed with the Diabetes Quality of Life Brief Clinical Inventory (DQOL-BCI) and the World Health Organization Quality of Life-BREF (WHOQOL-BREF), respectively. Diabetes distress was assessed with the Diabetes Distress Scale for Type 1 diabetes (T1-DDS).Results Eighty-nine T1D adults participated in the study, mostly females (65.2%), with a mean age of 39.8 (& PLUSMN; 11.5 years). They had on average 23 years of diabetes (& PLUSMN; 10.7) and they were on continuous subcutaneous insulin infusion therapy. Significant differences favoring the AHCL over the SAP + PLGM system were demonstrated by lower mean glucose levels, less time above range, lower scores on DQOL-BCI, T1-DDS, and higher scores on WHOQOL-BREF. Finally, the linear regression models revealed the association of time in range in most of the above aspects.Conclusion This study highlighted the advantages of the AHCL system over the SAP + PLGM system in the real-world setting in relation to general and diabetes-related QoL, diabetes distress, and glycaemic outcomes.
引用
收藏
页码:49 / 58
页数:10
相关论文
共 50 条
  • [21] HYPOGLYCAEMIA OCCURENCE AND RECOVERY DURING HOME USE OF CLOSED-LOOP INSULIN DELIVERY AND SENSOR-AUGMENTED PUMP THERAPY IN ADULTS WITH TYPE 1 DIABETES
    Ruan, Y.
    Bally, L.
    Thabit, H.
    Mader, J.
    Kojzar, H.
    Dellweg, S.
    Benesch, C.
    Hartnell, S.
    Leelarathna, L.
    Wilinska, M.
    Evans, M.
    Arnolds, S.
    Pieber, T.
    Hovorka, R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : A59 - A60
  • [22] Insulin pump therapy and glucose control during Ramadan fasting in an adolescent with type 1 diabetes: from an open-loop sensor-augmented pump therapy with predictive low-glucose management to an advanced hybrid closed-loop system
    Selmen Wannes
    Dhai Al Qusayer
    Sameh El Abed
    Manel Ben Fredj
    Acta Diabetologica, 2023, 60 : 851 - 855
  • [24] Insulin pump therapy and glucose control during Ramadan fasting in an adolescent with type 1 diabetes: from an open-loop sensor-augmented pump therapy with predictive low-glucose management to an advanced hybrid closed-loop system
    Wannes, Selmen
    Al Qusayer, Dhai
    El Abed, Sameh
    Ben Fredj, Manel
    ACTA DIABETOLOGICA, 2023, 60 (06) : 851 - 855
  • [25] EVALUATION OF HYBRID CLOSED-LOOP INSULIN DELIVERY IN PATIENTS WITH TYPE 1 DIABETES IN REAL-LIFE CONDITIONS: PREVIOUSLY USED THERAPY MATTERS ?
    Carnero, R.
    Rubin, G.
    Dain, A.
    Lequi, L.
    Saleme, A.
    Moretti, C.
    Vettore, M.
    Reynoso, N.
    Roldan, M.
    Charelli, C.
    Lopez Avila Carolina, C.
    Demarchi, M.
    Bringas, L.
    Vianco, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A168 - A169
  • [26] THE EFFECTS OF THE HYBRID CLOSED-LOOP SYSTEM ON SLEEP AND QUALITY OF LIFE MEASURES IN ADOLESCENTS WITH TYPE 1 DIABETES AND PARENTS
    Cobry, Erin
    Hamburger, Emily
    Jaser, Sarah S.
    ANNALS OF BEHAVIORAL MEDICINE, 2019, 53 : S510 - S510
  • [27] GLYCAEMIC CONTROL AFTER STARTING ADVANCED HYBRID CLOSED-LOOP SYSTEM IN CHILDREN WITH TYPE 1 DIABETES MELLITUS
    Saez Gallego, B.
    Ovejero Garcia, T.
    Garcia De Pablo, I.
    Diaz Martinez, C.
    Diaz Marrero, S.
    Ontoria Betencort, C.
    Espino Sanchez, J. R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A2 - A2
  • [28] INTEGRATED INSULIN PUMP AND CONTINUOUS GLUCOSE MONITORING TECHNOLOGY IN DIABETES CARE TODAY: A PERSPECTIVE OF REAL-LIFE EXPERIENCE WITH THE MINIMED™ 670G HYBRID CLOSED-LOOP SYSTEM
    Aleppo, Grazia
    Webb, Kimberly M.
    ENDOCRINE PRACTICE, 2018, 24 (07) : 684 - 692
  • [29] Improvements in Parental Sleep, Fear of Hypoglycemia, and Diabetes Distress With Use of an Advanced Hybrid Closed-Loop System
    Cobry, Erin C.
    Bisio, Alessandro
    Wadwa, R. Paul
    Breton, Marc D.
    DIABETES CARE, 2022, 45 (05) : 1292 - 1295
  • [30] Glycaemic outcomes and patient satisfaction after 3 months of use of an advanced hybrid closed-loop system use
    Beato-Vibora, P. I.
    Gallego-Gamero, F.
    Ambrojo-Lopez, A.
    Gil-Poch, E.
    Martin-Romo, I.
    Arroyo-Diez, F. J.
    DIABETOLOGIA, 2021, 64 (SUPPL 1) : 289 - 289