Automated contouring and statistical process control for plan quality in a breast clinical trial

被引:1
|
作者
Baroudi, Hana [1 ,2 ,5 ]
Nguyen, Callistus I. Huy Minh [2 ]
Maroongroge, Sean [3 ]
Smith, Benjamin D. [4 ]
Niedzielski, Joshua S. [2 ]
Shaitelman, Simona F. [4 ]
Melancon, Adam [2 ]
Shete, Sanjay [1 ]
Whitaker, Thomas J. [2 ]
Mitchell, Melissa P. [4 ]
Arzu, Isidora Yvonne [4 ]
Duryea, Jack [2 ]
Hernandez, Soleil [1 ,2 ]
El Basha, Daniel [1 ,2 ]
Mumme, Raymond [2 ]
Netherton, Tucker [2 ]
Hoffman, Karen [4 ]
Court, Laurence [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, UTHlth Houston Grad Sch Biomed Sci, Houston, TX USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Div Radiat Oncol, Houston, TX USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Breast Radiat Oncol, Div Radiat Oncol, Houston, TX USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, 1400 Pressler St,FCT8-6014, Houston, TX 77030 USA
基金
美国国家科学基金会;
关键词
Automated segmentation; Radiotherapy clinical trial; Breast cancer; Plan quality assurance; RADIOTHERAPY; TARGET; QA; SEGMENTATION;
D O I
10.1016/j.phro.2023.100486
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Automatic review of breast plan quality for clinical trials is time-consuming and has some unique challenges due to the lack of target contours for some planning techniques. We propose using an auto-contouring model and statistical process control to independently assess planning consistency in retrospective data from a breast radiotherapy clinical trial. Materials and methods: A deep learning auto-contouring model was created and tested quantitatively and qualitatively on 104 post-lumpectomy patients' computed tomography images (nnUNet; train/test: 80/20). The autocontouring model was then applied to 127 patients enrolled in a clinical trial. Statistical process control was used to assess the consistency of the mean dose to auto-contours between plans and treatment modalities by setting control limits within three standard deviations of the data's mean. Two physicians reviewed plans outside the limits for possible planning inconsistencies. Results: Mean Dice similarity coefficients comparing manual and auto-contours was above 0.7 for breast clinical target volume, supraclavicular and internal mammary nodes. Two radiation oncologists scored 95% of contours as clinically acceptable. The mean dose in the clinical trial plans was more variable for lymph node auto-contours than for breast, with a narrower distribution for volumetric modulated arc therapy than for 3D conformal treatment, requiring distinct control limits. Five plans (5%) were flagged and reviewed by physicians: one required editing, two had clinically acceptable variations in planning, and two had poor auto-contouring. Conclusions: An automated contouring model in a statistical process control framework was appropriate for assessing planning consistency in a breast radiotherapy clinical trial.
引用
下载
收藏
页数:7
相关论文
共 50 条
  • [21] Statistical process control for quality management in anaesthesiology
    Konrad, C
    Schmeck, J
    Schüpfer, G
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 2001, 42 (12): : 946 - 950
  • [22] Statistical process control in total quality management
    Yang, BC
    Liu, L
    Li, ZM
    NEW TRENDS OF INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT IN NEW CENTURY, 2001, : 413 - 418
  • [23] The Application of Statistical Process Control in Quality Management
    Li, Weiping
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON ECONOMY, MANAGEMENT AND EDUCATION TECHNOLOGY, 2016, 62 : 391 - 395
  • [24] Continuous Quality Improvement by Statistical Process Control
    Gejdos, Pavol
    INTERNATIONAL SCIENTIFIC CONFERENCE: BUSINESS ECONOMICS AND MANAGEMENT (BEM2015), 2015, 34 : 565 - 572
  • [25] Statistical process control for IMRT quality assurance
    Pawlicki, T
    Whitaker, M
    Price, RA
    Boyer, AL
    MEDICAL PHYSICS, 2003, 30 (06) : 1351 - 1351
  • [26] The Application of Statistical Process Control in Quality Management
    Liu, Yanqiu
    PROCEEDINGS OF THE 2016 2ND WORKSHOP ON ADVANCED RESEARCH AND TECHNOLOGY IN INDUSTRY APPLICATIONS, 2016, 81 : 118 - 121
  • [27] Statistical process control for radiotherapy quality assurance
    Pawlicki, T
    Whitaker, M
    Boyer, AL
    MEDICAL PHYSICS, 2005, 32 (09) : 2777 - 2786
  • [28] STATISTICAL PROCESS-CONTROL FOR TOTAL QUALITY
    ALI, SW
    JOHNS HOPKINS APL TECHNICAL DIGEST, 1992, 13 (02): : 317 - 325
  • [29] STATISTICAL PROCESS-CONTROL AND QUALITY PARTNERSHIPS
    HESS, JL
    BRIGHT, LR
    ISA TRANSACTIONS, 1991, 30 (01) : 69 - 78
  • [30] DISCOVERING THE PROCESS OF STATISTICAL QUALITY-CONTROL
    REYNOLDS, MJ
    ELASTOMERICS, 1986, 118 (03): : 28 - 31