Automated contouring and statistical process control for plan quality in a breast clinical trial

被引:1
|
作者
Baroudi, Hana [1 ,2 ,5 ]
Nguyen, Callistus I. Huy Minh [2 ]
Maroongroge, Sean [3 ]
Smith, Benjamin D. [4 ]
Niedzielski, Joshua S. [2 ]
Shaitelman, Simona F. [4 ]
Melancon, Adam [2 ]
Shete, Sanjay [1 ]
Whitaker, Thomas J. [2 ]
Mitchell, Melissa P. [4 ]
Arzu, Isidora Yvonne [4 ]
Duryea, Jack [2 ]
Hernandez, Soleil [1 ,2 ]
El Basha, Daniel [1 ,2 ]
Mumme, Raymond [2 ]
Netherton, Tucker [2 ]
Hoffman, Karen [4 ]
Court, Laurence [1 ,2 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, UTHlth Houston Grad Sch Biomed Sci, Houston, TX USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Div Radiat Oncol, Houston, TX USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Breast Radiat Oncol, Div Radiat Oncol, Houston, TX USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, 1400 Pressler St,FCT8-6014, Houston, TX 77030 USA
基金
美国国家科学基金会;
关键词
Automated segmentation; Radiotherapy clinical trial; Breast cancer; Plan quality assurance; RADIOTHERAPY; TARGET; QA; SEGMENTATION;
D O I
10.1016/j.phro.2023.100486
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Automatic review of breast plan quality for clinical trials is time-consuming and has some unique challenges due to the lack of target contours for some planning techniques. We propose using an auto-contouring model and statistical process control to independently assess planning consistency in retrospective data from a breast radiotherapy clinical trial. Materials and methods: A deep learning auto-contouring model was created and tested quantitatively and qualitatively on 104 post-lumpectomy patients' computed tomography images (nnUNet; train/test: 80/20). The autocontouring model was then applied to 127 patients enrolled in a clinical trial. Statistical process control was used to assess the consistency of the mean dose to auto-contours between plans and treatment modalities by setting control limits within three standard deviations of the data's mean. Two physicians reviewed plans outside the limits for possible planning inconsistencies. Results: Mean Dice similarity coefficients comparing manual and auto-contours was above 0.7 for breast clinical target volume, supraclavicular and internal mammary nodes. Two radiation oncologists scored 95% of contours as clinically acceptable. The mean dose in the clinical trial plans was more variable for lymph node auto-contours than for breast, with a narrower distribution for volumetric modulated arc therapy than for 3D conformal treatment, requiring distinct control limits. Five plans (5%) were flagged and reviewed by physicians: one required editing, two had clinically acceptable variations in planning, and two had poor auto-contouring. Conclusions: An automated contouring model in a statistical process control framework was appropriate for assessing planning consistency in a breast radiotherapy clinical trial.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] The Application of Statistical Process Control on Quality Management
    Ma, Jing
    2018 INTERNATIONAL WORKSHOP ON ADVANCES IN SOCIAL SCIENCES (IWASS 2018), 2019, : 6 - 9
  • [32] IMPROVE QUALITY WITH STATISTICAL PROCESS-CONTROL
    BLOCK, SR
    CHEMICAL ENGINEERING PROGRESS, 1990, 86 (11) : 38 - 43
  • [33] Application of Statistical Software in the Process of Quality Control
    Wang Huiliang
    Yang Xiaoying
    RECENT ADVANCE IN STATISTICS APPLICATION AND RELATED AREAS, VOLS I AND II, 2009, : 358 - 362
  • [34] Clinical trial variability: Quality control in a randomized clinical trial
    McGregor, Marion
    Cambron, Jerrilyn A.
    Jedlicka, James
    Gudavalli, M. Ram
    Contemporary Clinical Trials, 2009, 30 (01) : 20 - 23
  • [35] A definition of software process quality based on statistical process control
    Li, Z
    Gong, B
    He, XG
    Yu, ZY
    Proceedings of the 11th Joint International Computer Conference, 2005, : 814 - 817
  • [36] QUALITY-CONTROL IN THE AUTOMATED CLINICAL LABORATORY
    PLAUT, D
    SILBERMAN, J
    AMERICAN JOURNAL OF MEDICAL TECHNOLOGY, 1983, 49 (04): : 213 - 218
  • [37] QUALITY CONTROL IN AUTOMATED CLINICAL CHEMICAL LABORATORY
    BUTTNER, H
    ZEITSCHRIFT FUR KLINISCHE CHEMIE UND KLINISCHE BIOCHEMIE, 1969, 7 (01): : 89 - &
  • [38] A 10-STEP PLAN FOR STATISTICAL PROCESS-CONTROL STUDIES
    PYZDEK, T
    QUALITY PROGRESS, 1985, 18 (07) : 18 - 20
  • [39] Statistical Process Control: Linear Accelerator Mechanical Quality Control
    Able, C. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S600 - S600
  • [40] A new statistical approach to automated quality control in manufacturing processes
    Milo, Michael W.
    Roan, Michael
    Harris, Bradley
    JOURNAL OF MANUFACTURING SYSTEMS, 2015, 36 : 159 - 167