Friction Tuned Mass Dampers in Seismic-Excited High-Rise Buildings with SSI Effects: A Reliability Assessment

被引:7
|
作者
Etedali, Sadegh [1 ]
Akbari, Morteza [1 ]
Seifi, Mohammad [1 ]
机构
[1] Birjand Univ Technol, Dept Civil Engn, POB 97175-569, Birjand, Iran
关键词
Reliability analysis; high-rise buildings; friction tuned mass damper; near-field earthquakes; soil-structure interaction effect; SMALL FAILURE PROBABILITIES; BASE-ISOLATED STRUCTURES; GROUND MOTIONS; OPTIMUM DESIGN; CUCKOO SEARCH; OPTIMIZATION; FTMD;
D O I
10.1142/S1793431122500221
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The probabilistic performance of the seismic-excited structures supplemented with passive control devices has recently received attention. Friction tuned mass damper (FTMD) devise as a novel passive control device is inspired by the idea of the combination of the friction mechanism with the traditional tuned mass damper (TMD) device. Although the application of the FTMD device has recently been considered for seismic control of structures, to the best of the authors' knowledge, a probabilistic reliability evaluation of the high-rise building equipped with FTMD under near-field earthquakes considering soil-structure interaction (SSI) effects has not yet been addressed in the literature. In the presence of uncertainties considered for the structural model, FTMD model, foundation and soil model, and stochastic near-fault ground motion model, the reliability analyses are carried out on a benchmark 40-story building equipped with FTMD considering SSI effects to estimate the failure probabilities of both structures with and without FTMD. Three soil types, three earthquake magnitudes, three fault distances, and three seismic performance levels which include 162 reliability analyses are considered for the extension of the study. Considering different near-fault earthquake model parameters, a total average reduction of 51.13%, 49.42%, and 17.50% is given for the maximum inter-story drift ratio response of the structure equipped with FTMD than the uncontrolled ones. It is found that ignoring the uncertainties may result in an inaccurate estimation of the seismic responses of the tall buildings especially those built on soft soil near faults. The results show that the FTMD passive device is not able to satisfy the requirements of the seismic codes at the performance level of immediate occupancy, especially in high earthquake magnitudes and structures built near the fault. However, for the seismic performance levels of life safety and collapse prevention, the FTMD reduces failure probabilities of the structures for most conditions of the earthquake magnitudes and fault distances. The efficiency of the FTMD in the reduction of failure probability is often declined by increasing the softness of soils, especially for severe earthquakes closer to the fault.
引用
收藏
页数:23
相关论文
共 50 条
  • [41] Analytical and experimental research on wind-induced vibration in high-rise buildings with tuned liquid column dampers
    Liu, MY
    Chiang, WL
    Chu, CR
    Lin, SS
    WIND AND STRUCTURES, 2003, 6 (01) : 71 - 90
  • [42] Optimal design and seismic performance of Multi-Tuned Mass Damper Inerter (MTMDI) applied to adjacent high-rise buildings
    De Domenico, Dario
    Qiao, Haoshuai
    Wang, Qinhua
    Zhu, Zhiwen
    Marano, Giuseppe
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2020, 29 (14):
  • [43] ASSESSMENT OF ENERGY POTENTIAL AND VIBRATION MITIGATION OF REGENERATIVE TUNED MASS DAMPERS ON WIND EXCITED TALL BUILDINGS
    Ni, Tao
    Zuo, Lei
    Kareem, Ahsan
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE 2011, VOL 1, PTS A AND B: 23RD BIENNIAL CONFERENCE ON MECHANICAL VIBRATION AND NOISE, 2012, : 333 - 342
  • [44] Efficiency and Robustness of Optimally Designed Tuned Mass Dampers for Mid- and High-Rise Buildings Under Far and Near-Field Earthquakes
    Farzam, Maziar Fahimi
    Basim, Mohammad Charkhtab
    Maroofiazar, Rasool
    JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2023, 11 (02) : 699 - 719
  • [45] A New Static Nonlinear Procedure for Assessment of Seismic Performance of High-rise Buildings
    Zhang, Q. W.
    Megawati, K.
    Huang, L. P.
    Pan, T. C.
    FRACTURE AND STRENGTH OF SOLIDS VII, PTS 1 AND 2, 2011, 462-463 : 478 - 483
  • [46] Experimental and numerical studies on the optimal design of tuned mass dampers for vibration control of high-rise structures
    Liu, Yanhui
    Wang, Kan
    Mercan, Oya
    Chen, Huating
    Tan, Ping
    ENGINEERING STRUCTURES, 2020, 211
  • [47] Closure to "Effect of Multiple Tuned Mass Dampers for Vibration Control in High-Rise Buildings" by Lekshmi Suresh and K. M. Mini
    Suresh, Lekshmi
    Mini, K. M.
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2021, 26 (01)
  • [48] Efficiency and Robustness of Optimally Designed Tuned Mass Dampers for Mid- and High-Rise Buildings Under Far and Near-Field Earthquakes
    Maziar Fahimi Farzam
    Mohammad Charkhtab Basim
    Rasool Maroofiazar
    Journal of Vibration Engineering & Technologies, 2023, 11 : 699 - 719
  • [49] Discussion of "Effect of Multiple Tuned Mass Dampers for Vibration Control in High-Rise Buildings" by Lekshmi Suresh and K. M. Mini
    Elias, Said
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2021, 26 (01)
  • [50] Mitigation of seismic pounding between RC twin high-rise buildings with piled raft foundation considering SSI
    Farghaly, Ahmed Abdelraheem
    Kontoni, Denise-Penelope N.
    EARTHQUAKES AND STRUCTURES, 2022, 22 (06) : 625 - 635