ASSESSMENT OF ENERGY POTENTIAL AND VIBRATION MITIGATION OF REGENERATIVE TUNED MASS DAMPERS ON WIND EXCITED TALL BUILDINGS

被引:0
|
作者
Ni, Tao [1 ]
Zuo, Lei [1 ]
Kareem, Ahsan
机构
[1] SUNY Stony Brook, Dept Mech Engn, Stony Brook, NY 11794 USA
关键词
Structural control; energy harvesting; wind force modeling; multiple tuned mass dampers; decentralized control; robustness; stroke; ACROSS-WIND; MODEL;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Significant amount of inherent vibration energy present in tall buildings as they oscillate under the action of wind is traditionally dissipated into heat by the building damping or damping devices like Tuned Mass Dampers (TMDs) introduced to ensure the structural safety and occupants' comfort. A portion of this large amount of vibration energy can be harvested if we replace the damping devices with appropriate energy harvesters and power electronics. Accordingly, this paper assesses the potential of harvestable energy from various TMD configurations and evaluates their effectiveness in mitigating building motion. The wind is modeled and simulated using an autoregressive model and the responses of the building to the across- and along-wind load are calculated via spectral approach. The classic TMD, parallel multiple TMDs, and series multiple TMDs are designed based on the decentralized H-2 control for optimal stiffness constants and damping coefficients. The performances, namely, the building acceleration, energy potential, and strokes of the TMDs, are studied and compared for different wind speeds and an actual recorded wind event. During high wind events, over 85 K W of power can be harvested from a building used in a benchmark study. TMDs in series configuration with significantly smaller mass than the classic single TMD can achieve similar performance level and energy harvesting with enhanced robustness, but they require larger strokes.
引用
收藏
页码:333 / 342
页数:10
相关论文
共 50 条
  • [1] EFFECT OF TUNED MASS DAMPERS ON WIND INDUCED RESPONSE OF TALL BUILDINGS
    TANAKA, H
    MAK, CY
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1983, 14 (1-3) : 357 - 368
  • [2] Suppression of vortex-excited vibration of tall buildings using tuned liquid dampers
    Chang, CC
    Gu, M
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1999, 83 : 225 - 237
  • [3] Energy regenerative tuned mass dampers in high-rise buildings
    Shen, Wenai
    Zhu, Songye
    Xu, You-Lin
    Zhu, Hong-Ping
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (02):
  • [4] Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter
    Giaralis, Agathoklis
    Petrini, Francesco
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (09)
  • [5] CONTROL OF WIND-INDUCED TALL BUILDING VIBRATION BY TUNED MASS DAMPERS
    XU, YL
    KWOK, KCS
    SAMALI, B
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1992, 40 (01) : 1 - 32
  • [6] INTEGRATED MULTIPLE TUNED MASS DAMPERS FOR TALL BUILDINGS
    Moon, Kyoung Sun
    [J]. SUSTAINABLE SOLUTIONS IN STRUCTURAL ENGINEERING AND CONSTRUCTION, 2014, : 271 - 276
  • [7] Parametric study of active mass dampers for wind-excited tall buildings
    Xu, YL
    [J]. ENGINEERING STRUCTURES, 1996, 18 (01) : 64 - 76
  • [8] Wind Response Control of Tall Buildings with Flexible Foundation using Tuned Mass Dampers
    Elias, Said
    Matsagar, Vasant
    [J]. WIND ENGINEERING FOR NATURAL HAZARDS: MODELING, SIMULATION, AND MITIGATION OF WINDSTORM IMPACT ON CRITICAL INFRASTRUCTURE, 2018, (03): : 55 - 78
  • [9] Tunable Tuned Liquid Column Dampers with Multi Cells for Wind Vibration Control of Tall Buildings
    Kim, Dong-Ik
    Min, Kyung-Won
    Park, Ji-Hun
    Lee, Hye-Ri
    Kim, Jae-Keon
    Hwang, Kyu-Seok
    Gil, Yong-Sik
    [J]. SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2012, PTS 1 AND 2, 2012, 8345
  • [10] Mitigation of wind response of a tall building using semi-active tuned mass dampers
    Kang, Joowon
    Kim, Hyun-Su
    Lee, Dong-Guen
    [J]. STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2011, 20 (05): : 552 - 565