Friction Tuned Mass Dampers in Seismic-Excited High-Rise Buildings with SSI Effects: A Reliability Assessment

被引:7
|
作者
Etedali, Sadegh [1 ]
Akbari, Morteza [1 ]
Seifi, Mohammad [1 ]
机构
[1] Birjand Univ Technol, Dept Civil Engn, POB 97175-569, Birjand, Iran
关键词
Reliability analysis; high-rise buildings; friction tuned mass damper; near-field earthquakes; soil-structure interaction effect; SMALL FAILURE PROBABILITIES; BASE-ISOLATED STRUCTURES; GROUND MOTIONS; OPTIMUM DESIGN; CUCKOO SEARCH; OPTIMIZATION; FTMD;
D O I
10.1142/S1793431122500221
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The probabilistic performance of the seismic-excited structures supplemented with passive control devices has recently received attention. Friction tuned mass damper (FTMD) devise as a novel passive control device is inspired by the idea of the combination of the friction mechanism with the traditional tuned mass damper (TMD) device. Although the application of the FTMD device has recently been considered for seismic control of structures, to the best of the authors' knowledge, a probabilistic reliability evaluation of the high-rise building equipped with FTMD under near-field earthquakes considering soil-structure interaction (SSI) effects has not yet been addressed in the literature. In the presence of uncertainties considered for the structural model, FTMD model, foundation and soil model, and stochastic near-fault ground motion model, the reliability analyses are carried out on a benchmark 40-story building equipped with FTMD considering SSI effects to estimate the failure probabilities of both structures with and without FTMD. Three soil types, three earthquake magnitudes, three fault distances, and three seismic performance levels which include 162 reliability analyses are considered for the extension of the study. Considering different near-fault earthquake model parameters, a total average reduction of 51.13%, 49.42%, and 17.50% is given for the maximum inter-story drift ratio response of the structure equipped with FTMD than the uncontrolled ones. It is found that ignoring the uncertainties may result in an inaccurate estimation of the seismic responses of the tall buildings especially those built on soft soil near faults. The results show that the FTMD passive device is not able to satisfy the requirements of the seismic codes at the performance level of immediate occupancy, especially in high earthquake magnitudes and structures built near the fault. However, for the seismic performance levels of life safety and collapse prevention, the FTMD reduces failure probabilities of the structures for most conditions of the earthquake magnitudes and fault distances. The efficiency of the FTMD in the reduction of failure probability is often declined by increasing the softness of soils, especially for severe earthquakes closer to the fault.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Vibration control in high-rise buildings with tuned liquid dampers- Numerical simulation and engineering applications
    Zhou, Zijie
    Xie, Zhuangning
    Zhang, Lele
    WIND AND STRUCTURES, 2023, 36 (02) : 91 - 103
  • [32] Reliability and fragility assessment of the mid- and high-rise wood buildings subjected to bidirectional seismic excitation
    Hong, H. P.
    Yang, S. C.
    ENGINEERING STRUCTURES, 2019, 201
  • [33] Seismic assessment of high-rise buildings through dynamic nonlinear analysis
    Wu, Xiuwen
    Lin, Daoyun
    ANNALS OF GEOPHYSICS, 2022, 65
  • [34] PROBABILISTIC SEISMIC DEMAND MODELS AND RISK ASSESSMENT FOR HIGH-RISE BUILDINGS
    Zheng, Xiao-Wei
    Li, Hong-Nan
    Zhang, Ying-Ying
    Yin, Shi-Ping
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 (09): : 31 - 39
  • [35] Distributed Multiple Tuned Mass Dampers for Wind Vibration Response Control of High-Rise Building
    Elias, Said
    Matsagar, Vasant
    JOURNAL OF ENGINEERING, 2014, 2014
  • [36] Viscoelastic Coupling Dampers for Enhanced Multiple Seismic Hazard Level Performance of High-Rise Buildings
    MacKay-Lyons, Renee
    Christopoulos, Constantin
    Montgomery, Michael
    EARTHQUAKE SPECTRA, 2018, 34 (04) : 1847 - 1867
  • [37] Passive control of super high-rise buildings using hysteric tuned mass damper
    Kaneko K.
    Kaneko, Kensaku, 2016, Architectural Institute of Japan (81): : 459 - 469
  • [38] Effects of tuned liquid dampers on the nonlinear seismic responses of high-rise structures using real-time hybrid simulations
    Tang, Zhenyun
    Sheng, Jingyu
    Dong, Yue
    JOURNAL OF BUILDING ENGINEERING, 2023, 70
  • [39] Seismic performance assessment of steel strip dampers equipped in high-rise steel frame
    Zhai, Zhipeng
    Guo, Wei
    Yu, Zhiwu
    Hu, Yao
    Ma, Chenzhi
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 177
  • [40] Effects of basement stories on seismic response of high-rise buildings considering
    Ma, Jian-xun
    Mohammed, El Hoseny
    Pang, Pan-wang
    Li, Wen-xiao
    Yan, Hong-xiang
    ROCK AND SOIL MECHANICS, 2024, 45 (09) : 2808 - 2822