Evaluating the Usability of a 3D-Printed Video Laryngoscope for Tracheal Intubation of a Manikin

被引:1
|
作者
Fonternel, Theodorus [1 ,4 ]
van Rooyen, Hendrik [2 ]
Joubert, Gina [3 ]
Turton, Edwin [1 ]
机构
[1] Univ Free State, Fac Hlth Sci, Sch Clin Med, Dept Anaesthesiol, Bloemfontein, South Africa
[2] Scoltramed, Bloemfontein, South Africa
[3] Univ Free State, Fac Hlth Sci, Sch Biomed Sci, Dept Biostat, Bloemfontein, South Africa
[4] Univ Free State, Fac Hlth Sci, Dept Anaesthesiol, 205 Nelson Mandela Dr, ZA-9300 Bloemfontein, South Africa
基金
新加坡国家研究基金会;
关键词
3D printing; CMAC & REG; first pass; innovation; video laryngoscope; AIRWAY ANATOMY; VIDEOLARYNGOSCOPY; CLASSIFICATION; DESATURATION;
D O I
10.2147/MDER.S405833
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Compared to direct laryngoscopy, videolaryngoscopy (VL) can provide improved laryngeal and glottic view, higher intubation success rates in patients with a known or predicted difficult airway and reduced incidence of laryngeal/airway trauma. However, the cost and availability of these devices handicap its use in resource-restricted facilities. The objective was to design and manufacture a novel VL using additive manufacturing (AM) and evaluate its usability on an intubation manikin by comparing it to one of the most common video laryngoscopes used in clinical practice, the CMAC (R), by measuring the time to first pass of the endotracheal tube as the main outcome. Methods: A randomised cross-over study was performed with 36 anaesthetists attempting tracheal intubation of a manikin. The novel 3D-printed hyperangulated VL blade was compared to a CMAC (R) VL (D-blade). Participants had no prior experience or training with the novel device. The participants included consultants, registrars/trainees and medical officers in the Department of Anaesthesiology at the University of the Free State (UFS) in South Africa. Results: The CMAC (R) had a statistically shorter time to first pass (median 13.8 seconds) compared to the 3D-printed model (median 19.0 seconds) (95% confidence interval [CI] 1.0-6.2; P=0.0013). No failed attempts occurred with either device. Conclusion: Intubation times were faster with the CMAC (R) than with the novel device. However, with a comparable intubation success rate, 3D printing technology potentially can improve access to video laryngoscopy. Further design improvements, validation of materials and manufacturing processes are required before 3D-printed laryngoscope blades can be used in human subjects.
引用
收藏
页码:157 / 165
页数:9
相关论文
共 50 条
  • [41] Comparing Alba 3D printed video laryngoscope vs. video laryngoscope C-MAC® vs. direct macintosh laryngoscope operated by medical students: A randomized, crossover, manikin study
    Anzari, Raja Ahmad
    Kadarsah, Rudi Kurniadi
    Rachman, Iwan Abdul
    PERIOPERATIVE CARE AND OPERATING ROOM MANAGEMENT, 2024, 35
  • [42] COMPARISON OF TRACHEAL INTUBATION USING CONVENTIONAL DIRECT LARYNGOSCOPE AND VIDEO LARYNGOSCOPE DURING UNEXPECTED CARDIOPULMONARY RESUSCITATION
    Lee, D. H.
    Han, M.
    Jung, J. Y.
    An, J. Y.
    Koh, Y.
    Lim, C-M
    Huh, J. W.
    Hong, S-B
    Jin, J.
    INTENSIVE CARE MEDICINE, 2014, 40 : S271 - S271
  • [43] Use of a tracheal tube introducer guide to facilitate difficult intubation with a video laryngoscope
    Glenn P. McGuire
    Tze Ping Tan
    David T. Wong
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2014, 61 : 682 - 683
  • [44] Use of a tracheal tube introducer guide to facilitate difficult intubation with a video laryngoscope
    McGuire, Glenn P.
    Tan, Tze Ping
    Wong, David T.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2014, 61 (07): : 682 - 683
  • [45] Tracheal Intubation Performed with GlideScope® Video Laryngoscope and Direct Laryngoscopy in Neonates and Infants
    Xue, Fu-Shan
    Cheng, Yi
    Wang, Qiang
    ANESTHESIOLOGY, 2012, 117 (04) : 914 - 915
  • [46] Video screen visualization patterns when using a video laryngoscope for tracheal intubation: A systematic review
    Dean, Preston
    Kerrey, Benjamin
    JOURNAL OF THE AMERICAN COLLEGE OF EMERGENCY PHYSICIANS OPEN, 2022, 3 (01)
  • [47] A novel 3D-printed laryngoscope with integrated working channels for laryngeal surgery
    Kienle, Linus L.
    Schild, Leon R.
    Bohm, Felix
    Graesslin, Rene
    Greve, Jens
    Hoffmann, Thomas K.
    Schuler, Patrick J.
    FRONTIERS IN SURGERY, 2023, 10
  • [48] Air way scope, a portable video-laryngoscope, for confirmation of tracheal intubation
    Asai, Takashi
    Enomoto, Yoshiro
    Okuda, Yasuhisa
    RESUSCITATION, 2007, 72 (02) : 335 - 336
  • [49] Tracheal intubation in a simulated cervical spine immobilisation: The Macintosh laryngoscope versus supraglottic airway devices - A manikin study
    Aleksandrowicz, Dawid
    Gaszynski, Tomasz
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2018, 21 : 53 - 56
  • [50] Tracheal Intubation-Related Time Comparison: Macintosh Direct Laryngoscope & Video Laryngoscope (McGRATH®) in Novices & Experts
    Hamabe, Kosuke
    Inoue, Soichiro
    ANESTHESIA AND ANALGESIA, 2024, 139 (06):