Evaluating the Usability of a 3D-Printed Video Laryngoscope for Tracheal Intubation of a Manikin

被引:1
|
作者
Fonternel, Theodorus [1 ,4 ]
van Rooyen, Hendrik [2 ]
Joubert, Gina [3 ]
Turton, Edwin [1 ]
机构
[1] Univ Free State, Fac Hlth Sci, Sch Clin Med, Dept Anaesthesiol, Bloemfontein, South Africa
[2] Scoltramed, Bloemfontein, South Africa
[3] Univ Free State, Fac Hlth Sci, Sch Biomed Sci, Dept Biostat, Bloemfontein, South Africa
[4] Univ Free State, Fac Hlth Sci, Dept Anaesthesiol, 205 Nelson Mandela Dr, ZA-9300 Bloemfontein, South Africa
基金
新加坡国家研究基金会;
关键词
3D printing; CMAC & REG; first pass; innovation; video laryngoscope; AIRWAY ANATOMY; VIDEOLARYNGOSCOPY; CLASSIFICATION; DESATURATION;
D O I
10.2147/MDER.S405833
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Compared to direct laryngoscopy, videolaryngoscopy (VL) can provide improved laryngeal and glottic view, higher intubation success rates in patients with a known or predicted difficult airway and reduced incidence of laryngeal/airway trauma. However, the cost and availability of these devices handicap its use in resource-restricted facilities. The objective was to design and manufacture a novel VL using additive manufacturing (AM) and evaluate its usability on an intubation manikin by comparing it to one of the most common video laryngoscopes used in clinical practice, the CMAC (R), by measuring the time to first pass of the endotracheal tube as the main outcome. Methods: A randomised cross-over study was performed with 36 anaesthetists attempting tracheal intubation of a manikin. The novel 3D-printed hyperangulated VL blade was compared to a CMAC (R) VL (D-blade). Participants had no prior experience or training with the novel device. The participants included consultants, registrars/trainees and medical officers in the Department of Anaesthesiology at the University of the Free State (UFS) in South Africa. Results: The CMAC (R) had a statistically shorter time to first pass (median 13.8 seconds) compared to the 3D-printed model (median 19.0 seconds) (95% confidence interval [CI] 1.0-6.2; P=0.0013). No failed attempts occurred with either device. Conclusion: Intubation times were faster with the CMAC (R) than with the novel device. However, with a comparable intubation success rate, 3D printing technology potentially can improve access to video laryngoscopy. Further design improvements, validation of materials and manufacturing processes are required before 3D-printed laryngoscope blades can be used in human subjects.
引用
收藏
页码:157 / 165
页数:9
相关论文
共 50 条
  • [31] TRACHEAL INTUBATION USING McGRATH VIDEO LARYNGOSCOPE IN MYASTHENIA GRAVIS PATIENTS
    Manne, Venkata Sesha Sai Krishna
    Marupudi, Madhavi Latha
    Yelavarthy, Surendranath
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (56): : 9780 - 9785
  • [32] Comparison of three types of intubation stylets for tracheal intubation with a McGrath MAC® video laryngoscope by novice intubators in simulated cervical immobilisation: A randomised crossover manikin study
    Kim, Sung-Wook
    Kim, Ji-Hoon
    Kim, Young-Min
    Park, Jung Taek
    Choi, Seung Pill
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2018, 25 (01) : 27 - 32
  • [33] Glidescope Video Laryngoscope Use for Tracheal Intubation in a Patient with CHARGE Syndrome
    Saricicek, Vahap
    Mizrak, Ayse
    Sahin, Mehrican
    Goksu, Sitki
    Gul, Rauf
    Cesur, Mehmet
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2014, 42 (06) : 352 - 354
  • [34] Comparison of 3 video laryngoscopes against the Miller laryngoscope for tracheal intubation during infant resuscitation
    Szarpak, Lukasz
    Kurowski, Andrzej
    Truszewski, Zenon
    Czyzewski, Lukasz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (03): : 460 - 461
  • [35] Multilayer coating of a 3D-printed tracheal stent prevents tracheal stenosis
    Zhang, Tongtong
    Zhuang, Bo
    Zhang, Feng
    Yuan, Tianyu
    Chen, Ziyuan
    Yuan, Bochuan
    Wang, Shiqiang
    Qu, Wei
    Ma, Wei
    Du, Lina
    Jin, Yiguang
    APPLIED MATERIALS TODAY, 2024, 39
  • [36] Tracheal intubation in patients with Pierre Robin sequence. Successful use of a video intubation laryngoscope
    Schwarz, U
    Weiss, M
    ANAESTHESIST, 2001, 50 (02): : 118 - 121
  • [37] Comparison of Airtraq™ video-laryngoscope and Macintosh laryngoscope for tracheal intubation in adults-a randomised study
    Meena, Seema
    Chaudhary, Sujata
    Salhotra, Rashmi
    Bharti, Swati
    Khurana, Bismanjeet Kaur
    AIN SHAMS JOURNAL OF ANESTHESIOLOGY, 2023, 15 (01)
  • [38] Macintosh laryngoscope and i-view™ and C-MAC® video laryngoscopes for tracheal intubation with an aerosol box: a randomized crossover manikin study
    Toshiyuki Nakanishi
    Yoshiki Sento
    Yuji Kamimura
    Kazuya Sobue
    JA Clinical Reports, 7
  • [39] Macintosh laryngoscope and i-view™ and C-MAC® video laryngoscopes for tracheal intubation with an aerosol box: a randomized crossover manikin study
    Nakanishi, Toshiyuki
    Sento, Yoshiki
    Kamimura, Yuji
    Sobue, Kazuya
    JA CLINICAL REPORTS, 2021, 7 (01)
  • [40] Tracheal intubation with restricted access: a randomised comparison of the Pentax-Airway Scope and Macintosh laryngoscope in a manikin
    Asai, T.
    ANAESTHESIA, 2009, 64 (10) : 1114 - 1117