Optimal Dosage of Indocyanine Green Fluorescence for Intraoperative Positive Staining in Laparoscopic Anatomical Liver Resection

被引:5
|
作者
Kasai, Meidai [1 ]
Aihara, Tsukasa [1 ]
Ikuta, Shinichi [1 ]
Nakajima, Takayoshi [2 ]
Yamanaka, Naoki [1 ]
机构
[1] Meiwa Hosp, Dept Surg, Nishinomiya, Hyogo, Japan
[2] Meiwa Hosp, Dept Surg, Nishinomiya, Japan
关键词
roc curve analysis; positive staining; indocyanine green; fluorescence imaging technology; laparoscopic anatomical liver resection; NAVIGATION;
D O I
10.7759/cureus.46771
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionFluorescence imaging technology, specifically utilizing indocyanine green (ICG), has emerged as a valuable tool in laparoscopic hepatectomy. In particular, laparoscopic anatomical liver resection (ALR) has benefited from the implementation of both positive and negative staining methods. A case series study reported a success rate of 53% for the positive staining method, citing potential issues regarding the proper ICG dosage needed for accurate fluorescence. Thus, it is crucial to conduct research to investigate the optimal dosage for ICG-positive staining in clinical practice to maximize the benefits of this technique.Materials and methodsThis retrospective study was conducted at a single center, Meiwa Hospital, and received approval from the hospital's ethics committee in accordance with the Helsinki Declaration. We reviewed the records of 264 patients who underwent open and laparoscopic hepatectomies for benign and malignant liver diseases from January 2019 to January 2023. Of these, 18 patients who underwent laparoscopic ALR with the ICG-positive staining method were evaluated. Fluorescence-emitting segmental borders were assessed immediately after puncture (first stage) and during parenchymal dissection (second stage). In the first stage, we evaluated the intensity of fluorescence emission, categorizing it as "strong" or "weak." The absence of visible fluorescence emission was considered a puncture failure. During the second stage of evaluation, from parenchymal resection to completion, we assessed the sustainability of fluorescence emission, defining it as "clear" or "contaminated." Both evaluations were subjectively judged by three surgeons at our center. The ICG quantity per targeted portal vein-bearing liver volume (mg/100 mL) was calculated for each patient, and the optimal dosage was determined using receiver operating characteristic (ROC) curve analysis. To ascertain the minimum value for adequate fluorescence emission intensity, ROC curve analysis was performed to discriminate between binary outcomes of "strong" or "weak" emission. Furthermore, to establish the maximum value for maintaining a clear fluorescence border, ROC curve analysis was conducted to discriminate between "clear" and "contaminated" during the second evaluation.ResultsAmong the 18 successful puncture cases, the first-stage evaluation of fluorescence intensity revealed 14 punctures with "strong" intensity and four punctures with "weak" intensity. In the second-stage evaluation, 13 cases demonstrated "clear" borders, while five cases exhibited "contaminated" borders. ROC curve analysis was performed to determine the optimal ICG dose for adequate fluorescence intensity and preservation of clear borders during dissection. The analysis indicated that the appropriate ICG dose for achieving optimal intensity was 0.028 mg/100 mL (area under the curve [AUC]: 0.893), while the dose that prevented contamination of fluorescence in non-target areas until after dissection was 0.083 mg/100 mL (AUC: 0.723).ConclusionsLaparoscopic anatomical resection using the positive staining method requires an optimal ICG dosage of 0.028-0.083 mg per 100 mL of liver volume. By employing this methodology, more precise and safer laparoscopic anatomical resections can be conducted, thereby enhancing the safety of the surgical procedure for patients.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Image-Guided Liver Mapping Using Fluorescence Navigation System with Indocyanine Green for Anatomical Hepatic Resection
    Takeshi Aoki
    Daisuke Yasuda
    Yoshinori Shimizu
    Masanori Odaira
    Takashi Niiya
    Tomokazu Kusano
    Keitaro Mitamura
    Ken Hayashi
    Noriyuki Murai
    Tomotake Koizumi
    Hirohisa Kato
    Yuta Enami
    Mitsuharu Miwa
    Mitsuo Kusano
    World Journal of Surgery, 2008, 32 : 1763 - 1767
  • [42] Anatomical Liver Resections Guided by 3-Dimensional Parenchymal Staining Using Fusion Indocyanine Green Fluorescence Imaging
    Inoue, Yosuke
    Arita, Junichi
    Sakamoto, Taro
    Ono, Yoshihiro
    Takahashi, Michiro
    Takahashi, Yu
    Kokudo, Norihiro
    Saiura, Akio
    ANNALS OF SURGERY, 2015, 262 (01) : 105 - 111
  • [43] Intraoperative Laparoscopic Near-Infrared Fluorescence Cholangiography to Facilitate Anatomical Identification: When to Give Indocyanine Green and How Much
    Zarrinpar, Ali
    Dutson, Erik P.
    Mobley, Constance
    Busuttil, Ronald W.
    Lewis, Catherine E.
    Tillou, Areti
    Cheaito, Ali
    Hines, O. Joe
    Agopian, Vatche G.
    Hiyama, Darryl T.
    SURGICAL INNOVATION, 2016, 23 (04) : 360 - 365
  • [44] Use of Indocyanine Green Fluorescence in Assisting Pediatric Laparoscopic Resection of Hepatocellular Carcinoma
    Wong, K.
    Chung, P.
    Chok, K.
    PEDIATRIC BLOOD & CANCER, 2019, 66 : S500 - S500
  • [45] Laparoscopic Resection of a Hepatic Epithelioid Angiomyolipoma Revealed by Indocyanine Green Fluorescence Imaging
    Mochizuki, Kiyotaka
    Aoki, Takeshi
    Kusano, Tomokazu
    Tomioka, Kodai
    Tashiro, Yoshihiko
    Koizumi, Tomotake
    Matsuda, Kazuhiro
    Enami, Yuta
    Yamochi, Toshiko
    Murakami, Masahiko
    AMERICAN SURGEON, 2023, 89 (05) : 2061 - 2063
  • [46] A comparison of indocyanine green fluorescence and laparoscopic ultrasound for detection of liver tumors
    Kose, Emin
    Kahramangil, Bora
    Aydin, Husnu
    Donmez, Mustafa
    Takahashi, Hideo
    Acevedo-Moreno, Lou-Anne
    Sasaki, Kazunari
    Aucejo, Federico
    Berber, Eren
    HPB, 2020, 22 (05) : 764 - 769
  • [47] Intraoperative Use of Indocyanine Green Fluorescence Videography for Resection of a Spinal Cord Hemangioblastoma COMMENTS
    Mahan, Mark
    Spetzler, Robert F.
    Benzel, Edward C.
    Kaiser, Michael G.
    NEUROSURGERY, 2010, 67 (03) : 302 - 303
  • [48] Augmented Reality Navigation Plus Indocyanine Green Fluorescence Imaging Can Accurately Guide Laparoscopic Anatomical Segment 8 Resection
    Tao, Haisu
    Wang, Zhuangxiong
    Zeng, Xiaojun
    Hu, Haoyu
    Li, Jiang
    Lin, Jinyu
    Lin, Wenjun
    Fang, Chihua
    Yang, Jian
    ANNALS OF SURGICAL ONCOLOGY, 2023, 30 (12) : 7373 - 7383
  • [49] Indocyanine green fluorescence image-guided laparoscopic anatomical S2/3 resection using the TICGL technique
    Wenjun Lin
    Xinci Li
    Zhuangxiong Wang
    Haisu Tao
    Chihua Fang
    Jian Yang
    Surgical Endoscopy, 2024, 38 : 1069 - 1076
  • [50] Indocyanine green fluorescence image-guided laparoscopic anatomical S2/3 resection using the TICGL technique
    Lin, Wenjun
    Li, Xinci
    Wang, Zhuangxiong
    Tao, Haisu
    Fang, Chihua
    Yang, Jian
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2024, 38 (02): : 1029 - 1044