Optimal Dosage of Indocyanine Green Fluorescence for Intraoperative Positive Staining in Laparoscopic Anatomical Liver Resection

被引:5
|
作者
Kasai, Meidai [1 ]
Aihara, Tsukasa [1 ]
Ikuta, Shinichi [1 ]
Nakajima, Takayoshi [2 ]
Yamanaka, Naoki [1 ]
机构
[1] Meiwa Hosp, Dept Surg, Nishinomiya, Hyogo, Japan
[2] Meiwa Hosp, Dept Surg, Nishinomiya, Japan
关键词
roc curve analysis; positive staining; indocyanine green; fluorescence imaging technology; laparoscopic anatomical liver resection; NAVIGATION;
D O I
10.7759/cureus.46771
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionFluorescence imaging technology, specifically utilizing indocyanine green (ICG), has emerged as a valuable tool in laparoscopic hepatectomy. In particular, laparoscopic anatomical liver resection (ALR) has benefited from the implementation of both positive and negative staining methods. A case series study reported a success rate of 53% for the positive staining method, citing potential issues regarding the proper ICG dosage needed for accurate fluorescence. Thus, it is crucial to conduct research to investigate the optimal dosage for ICG-positive staining in clinical practice to maximize the benefits of this technique.Materials and methodsThis retrospective study was conducted at a single center, Meiwa Hospital, and received approval from the hospital's ethics committee in accordance with the Helsinki Declaration. We reviewed the records of 264 patients who underwent open and laparoscopic hepatectomies for benign and malignant liver diseases from January 2019 to January 2023. Of these, 18 patients who underwent laparoscopic ALR with the ICG-positive staining method were evaluated. Fluorescence-emitting segmental borders were assessed immediately after puncture (first stage) and during parenchymal dissection (second stage). In the first stage, we evaluated the intensity of fluorescence emission, categorizing it as "strong" or "weak." The absence of visible fluorescence emission was considered a puncture failure. During the second stage of evaluation, from parenchymal resection to completion, we assessed the sustainability of fluorescence emission, defining it as "clear" or "contaminated." Both evaluations were subjectively judged by three surgeons at our center. The ICG quantity per targeted portal vein-bearing liver volume (mg/100 mL) was calculated for each patient, and the optimal dosage was determined using receiver operating characteristic (ROC) curve analysis. To ascertain the minimum value for adequate fluorescence emission intensity, ROC curve analysis was performed to discriminate between binary outcomes of "strong" or "weak" emission. Furthermore, to establish the maximum value for maintaining a clear fluorescence border, ROC curve analysis was conducted to discriminate between "clear" and "contaminated" during the second evaluation.ResultsAmong the 18 successful puncture cases, the first-stage evaluation of fluorescence intensity revealed 14 punctures with "strong" intensity and four punctures with "weak" intensity. In the second-stage evaluation, 13 cases demonstrated "clear" borders, while five cases exhibited "contaminated" borders. ROC curve analysis was performed to determine the optimal ICG dose for adequate fluorescence intensity and preservation of clear borders during dissection. The analysis indicated that the appropriate ICG dose for achieving optimal intensity was 0.028 mg/100 mL (area under the curve [AUC]: 0.893), while the dose that prevented contamination of fluorescence in non-target areas until after dissection was 0.083 mg/100 mL (AUC: 0.723).ConclusionsLaparoscopic anatomical resection using the positive staining method requires an optimal ICG dosage of 0.028-0.083 mg per 100 mL of liver volume. By employing this methodology, more precise and safer laparoscopic anatomical resections can be conducted, thereby enhancing the safety of the surgical procedure for patients.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Usefulness of indocyanine green fluorescence in laparoscopic resection of choledochal cyst in children
    Garcia-Hernandez, Carlos
    Cabrera-Gonzalez, Hugo
    Carvajal-Figueroa, Lourdes
    Archivaldo-Garcia, Christian
    Valero-Mamani, Romer Jesus
    Martinez-Flores, Ramiro Adebel
    JOURNAL OF PEDIATRIC SURGERY CASE REPORTS, 2022, 76
  • [32] Discussion of "Application of Indocyanine Green Fluorescence (ICG) as an Adjuvant to Laparoscopic Ultrasound in Minimally Invasive Liver Resection"
    Wahi, Jessica E.
    Ben-David, Kfir
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2021, 31 (05): : 524 - 525
  • [33] Usefulness of Indocyanine Green-Fluorescence Imaging for Visualization of the Bile Duct During Laparoscopic Liver Resection
    Kawaguchi, Yoshikuni
    Velayutham, Vimalraj
    Fuks, David
    Christidis, Christos
    Kokudo, Norihiro
    Gayet, Brice
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2015, 221 (06) : E113 - E117
  • [34] Intraoperative Use of Indocyanine Green Fluorescence Videography for Resection of a Spinal Cord Hemangioblastoma
    Hwang, Steven W.
    Malek, Adel M.
    Schapiro, Robert
    Wu, Julian K.
    NEUROSURGERY, 2010, 67 (03) : 300 - 302
  • [35] Evaluation of Indocyanine Green Fluorescence Imaging for Intraoperative Identification of Liver Malignancy
    Rodriguez, Jorge G. Zarate
    Grendar, Jan
    Wolf, Ronald F.
    Jutric, Zeljka
    Hansen, Paul D.
    Cassera, Maria A.
    Hammill, Chet W.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 39
  • [36] ASO Visual Abstract: Pure Laparoscopic Anatomic Resection of Liver Segment 4 with Middle Hepatic Vein Involvement Using Indocyanine Green Fluorescence Staining
    Liu, Yani
    Peng, Yufu
    Wei, Yonggang
    ANNALS OF SURGICAL ONCOLOGY, 2024, 31 (03) : 1848 - 1848
  • [37] Anatomical Laparoscopic Hepatectomy for Hepatocellular Carcinoma Using Indocyanine Green Fluorescence Imaging
    Sakoda, Masahiko
    Ueno, Shinichi
    Iino, Satoshi
    Hiwatashi, Kiyokazu
    Minami, Koji
    Kawasaki, Yota
    Kurahara, Hiroshi
    Mataki, Yukou
    Maemura, Kousei
    Uenosono, Yoshikazu
    Shinchi, Hiroyuki
    Natsugoe, Shoji
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2014, 24 (12): : 878 - 882
  • [38] Image-guided liver mapping using fluorescence navigation system with indocyanine green for anatomical hepatic resection
    Aoki, Takeshi
    Yasuda, Daisuke
    Shimizu, Yoshinori
    Odaira, Masanori
    Niiya, Takashi
    Kusano, Tomokazu
    Mitamura, Keitaro
    Hayashi, Ken
    Murai, Noriyuki
    Koizumi, Tomotake
    Kato, Hirohisa
    Enami, Yuta
    Miwa, Mitsuharu
    Kusano, Mitsuo
    WORLD JOURNAL OF SURGERY, 2008, 32 (08) : 1763 - 1767
  • [39] Full Laparoscopic Anatomical Segment 8 Resection for Hepatocellular Carcinoma Using the Glissonian Approach with Indocyanine Green Dye Fluorescence
    Giammauro Berardi
    Go Wakabayashi
    Kazuharu Igarashi
    Takehiro Ozaki
    Naoyuki Toyota
    Akihiko Tsuchiya
    Kou Nishikawa
    Annals of Surgical Oncology, 2019, 26 : 2577 - 2578
  • [40] Full Laparoscopic Anatomical Segment 8 Resection for Hepatocellular Carcinoma Using the Glissonian Approach with Indocyanine Green Dye Fluorescence
    Berardi, Giammauro
    Wakabayashi, Go
    Igarashi, Kazuharu
    Ozaki, Takehiro
    Toyota, Naoyuki
    Tsuchiya, Akihiko
    Nishikawa, Kou
    ANNALS OF SURGICAL ONCOLOGY, 2019, 26 (08) : 2577 - 2578